Static Load Test

Download as pptx, pdf, or txt
Download as pptx, pdf, or txt
You are on page 1of 9

STATIC LOAD TEST

19m BRIDGE BEAM

ELS PRE-CAST FACTORY


BEMMULLA

DATA OF BRIDGE BEAM


19.0

m RDA STANDARD BRIDGE

BEAM (DRAWING NO. T/B/508)


BEAM

NO. 01

CASTING
TEST

DATE 22ND JUNE 2014

LOAD 8.4MT

TESTING PROCEDURE

EACH END OF THE BRIDGE BEAM


SUPPORTED ON RUBBER STRIP (75mm x
12mm) POSITIONED AT BEARING POINT
(230mm FROM BOTH ENDS)

TESTING PROCEDURE

LOADING ARRANGEMENT

TESTING PROCEDURE
REACTION

FOR THE LOADING OBTAINED BY JACKING

AGAINST THE LOADS USING 50 MT CAPACITY


HYDRAULIC JACK.
SETTLEMENT

MEASURING DIAL GAUGES FIXED AT

EACH SUPPORT, 1/4TH POSITION ON BOTH SUPPORTS


AND THE CENTER.

TESTING PROCEDURE
THE

MUST BE LOADED WITH A CENTER LOAD

APPLIED USING HYDRAULIC JACK IN STEPS OF


1.0 TONS UP TO A LOADING OF 8.4 MT.
OBSERVED

WHETHER CRACKS DEVELOP

DURING LOADING.

TESTING PROCEDURE
NET

DISPLACEMENT AT THE CENTER OF THE


BEAM RELATIVE TO THE DISPLACEMENT OF
END OF THE BEAM CALCULATED AT EACH
LOADING AND UNLOADING.

NET
DISPLACEMENT
AT CENTER

TOTAL
DISPLACEMENT
AT CENTER

AVERAGE
DISPLACEMENT
AT ENDS

RESULTS
ACTUAL

NET DISPLACEMENT

OF THE BEAM COMPARED TO


THEORETICAL DISPLACEMENT
CALCULATED BY L/250.

THANK

YOU