The Official Reset Proceedure

Courtesy of a BMW tech on another forum, ...with thanks.


Initialization is performed on the power window switch of the relevant door.
Requirements for correct initialization:
Initialization with engine running
Convertible top, doors and windows closed
Initialization comprises:
Erasure of initialization
Reinitialization
An initialization must be performed:
In the event of malfunctions, e.g. no one-touch control function, no opening or if available
no comfort function is possible
After the power window drive has been replaced
After work is carried out on the power window mechanism
After a power supply interruption, e.g. disconnection of the battery or disconnection of the
power supply to the door
After the door window glass has been removed and installed or replaced
After adjustment work on the door window glass
After adjustment work on the convertible top
After replacement of seals
Erasure of initialization:
Open door window glass fully
Operate power window switch in "Open" position four times within 10 seconds
This erases initialization of the power window, anti-trapping protection and toll function are
inactive.
Check whether one-touch control (toll) function is inactive, otherwise repeat procedure.
Reinitialization:
Avoid a break between the two steps!
Open door window glass fully
Operate and hold power window switch in "Close" position (second switch stage)
Once the upper end position has been reached, hold power window switch in "Close"
position for approx. 2 seconds longer
Open door window glass fully
Operate and hold power window switch in "Close" position (second switch stage)
Once the upper end position has been reached, hold power window switch in "Close"
position for approx. 2 seconds longer