Energy

Download as pdf or txt
Download as pdf or txt
You are on page 1of 20

1

Non-Conventional and Conventional


Sources of Energy


Non-Conventional and Conventional Sources of Energy

1.0

NON-CONVENTIONAL

The contemporary non-conventional sources of energy like wind, tidal, solar etc. were the
conventional sources until James Watt invented the steam engine in the eighteenth century.
In fact, the New World was explored by man using wind-powered ships only. The nonconventional sources are available free of cost, are pollution-free and inexhaustible. Man has
used these sources for many centuries in propelling ships, driving windmills for grinding corn
and pumping water, etc. Because of the poor technologies then existing, the cost of harnessing
energy from these sources was quite high. Also because of uncertainty of period of availability
and the difficulty of transporting this form of energy, to the place of its use are some of the
factors which came in the way of its adoption or development. The use of fossil fuels and
nuclear energy replaced totally the non-conventional methods because of inherent advantages
of transportation and certainty of availability; however these have polluted the atmosphere to
a great extent. In fact, it is feared that nuclear energy may prove to be quite hazardous in case
it is not properly controlled.
In 1973 the Arab nations placed an embargo on petroleum. People began to realise that
the fossil fuels are not going to last longer and that remaining reserves should be conserved for
the petro-chemical industry. But unfortunately, both nuclear and coal energy pose serious
environmental problems. The combustion of coal may upset the planets heat balance. The
production of carbondioxide and sulphurdioxide may adversely affect the ability of the planet
to produce food for its people. Coal is also a valuable petro-chemical and from long term point
of view it is undesirable to burn coal for generation of electricity. The major difficulty with
nuclear energy is waste disposal and accidental leakage (e.g. leakage at Chernobyl nuclear
power plant).
As a result of these problems, it was decided by almost all the countries to develop and
harness the non-conventional sources of energy, even though they are relatively costlier as
compared to fossil-fuel sources. It is hoped that with advancement in technology and more
3

GENERATION, DISTRIBUTION AND UTILIZATION OF ELECTRICAL ENERGY

research in the field of development of non-conventional sources of energy, these sources may
prove to be cost-effective as well. The future of wind, solar, tidal and other energy sources is
bright and these will play an important role in the world energy scenerio.
The following sections have been devoted to the study of some of the important nonconventional sources of energy.

1.1

TIDAL POWER

1.1.1 Introduction
Tidal or lunar energy as it is sometimes called, has been known to mankind since time
immemorial. Various devices, particularly the mills were operated using tidal power. In the
past water supply of London was pumped to a water tower by a mill operated by the tidal
power (which consisted of a large paddle wheel, mounted on a raft and fastened between two of
the piers of old London Bridge). The tidal power has been used to irrigate fields in Germany
and to saw firewood in Canada.
Tides are caused by the combined gravitational forces of Sun and Moon on the waters of
the revolving Earth. When the gravitational forces due to the Sun and the Moon add together,
tides of maximum range, called spring tides, are obtained. On the other hand, when the two
forces oppose each other, tides of minimum range, called neap tides, are obtained. In one year
there are approximately 705 full tidal cycles.
1.1.2 Basic Schemes
It has been suggested, that for harnessing tidal power effectively the most practicable
method is the basin system. Here a portion of the sea is enclosed behind a dam or dams and
water is allowed to run through turbines, as the tide subsides.
The power available from a given head of water varies as the square of the head and
since the head varies with the tidal range, the power available at different sites from tidal
energy shows very wide variation. Various tidal basin systems have, therefore, been evolved,
in order to overcome this wide variation in availability of tidal power.
Single Basin System
The simplest scheme for developing tidal power is the single basin arrangement, in
which a single basin of constant area is provided with sluices (gates), large enough to admit
the tide, so that the loss of head is small. The level of water in the basin is the same as that of
the tide outside. When the tides are high, water is stored in the basin and sluice gates are
closed. When the tides are falling, sluices are opened to allow water to go through the turbine
to generate power. A head of water is obviously required for the turbine to generate water.
This continues to generate power till the level of the falling tides coincides with the level of the
next rising tide.
The major disadvantage of this single basin scheme is that it gives intermittent supply
of power, varying considerably over the period of operation. It is for this reason that the tidal
power has not been developed on a large scale. Also with this scheme, only about 50 per cent of
tidal energy is available.

NON-CONVENTIONAL AND CONVENTIONAL SOURCES OF ENERGY

Two Basin System


An improvement over the single basin system is the two-basin system. In this system, a
constant and continuous output is maintained by suitable adjustment of the turbine valves to
suit the head under which these turbines are operating.
A two-basin system regulates power output of an individual tide but it cannot take care
of the great difference in outputs between spring and neap tides. This system, therefore, provides
a partial solution to the problem, of getting a steady output of power from a tidal scheme.
This disadvantage can be overcome by the joint operation of tidal power and pumped
storage plant. During the period when the tidal power plant is producing more energy than
required, the pumped storage plant utilizes the surplus power for pumping water to the upper
reservoir. When the output of the tidal power plant is low, the pumped storage plant generates
electric power and feeds it to the system. This arrangement, even though technically feasible,
is much more expensive, as it calls for higher installed capacity for meeting a particular load.
This basic principle of joint operation of tidal power with steam plant, is also possible
when it is connected to a grid. In this case, whenever tidal power is available, the output of the
steam plant will be reduced by that extent which leads to saving in fuel and reduced wear and
tear of steam plant. This operation requires the capacity of steam power plant to be equal to
that of tidal power plant and makes the overall cost of power obtained from such a combined
scheme very high. In the system shown in Fig. 1.1, the two basins close to each other, operate
alternatively. One basin generates power when the tide is rising (basin getting filled up) and
the other basin generates power while the tide is falling (basin getting emptied). The two
basins may have a common power house or may have separate power house for each basin. In
both the cases, the power can be generated continuously. The system could be thought of as a
combination of two single basin systems, in which one is generating power during tiding cycle,
and the other is generating power during emptying.

Basin 1

Basin 2
Dyke
Sluice

Sluice
Power
house

Power
house

Fig. 1.1 Double Basin System

GENERATION, DISTRIBUTION AND UTILIZATION OF ELECTRICAL ENERGY

Cooperating double basin system. This scheme consists of two basins, at different elevation
connected through turbine. The sluices in the high and low level basin communicate with sea
water directly as shown in Fig. 1.2. The high level basin sluices are called the inlet sluices and
the low level as outlet sluices. Ths basio operation of the scheme is as follows.

High level basin

Low level basin

Power house
Inlet
sluices

Outlet
sluices

Dyke
S

Fig. 1.2 Cooperating Double Basin System

Let us assume that the upper basin is filled with water. The water is allowed to flow to
the lower basin through the turbine. Therefore, the level in the upper basin falls and that in
the lower basin rises. At an instant when the rising level in the basin is equal to the level of the
falling tide, the outlet gates are opened. When the tide reaches its lower most level, the outlet
gates are closed. After a while the tide rises. When its level becomes equal to the low level of
the upper basin, the inlet gates are opened. As a result, the level of the upper basin starts
rising. At the same time, the turbines are fed from the upper basin transferring water to the
lower basin, thus raising level of water there. When the tide reaches its peak value, the inlet
gates are called again. Thus the cycle is repeated.
1.1.3 Turbines for Tidal Power
Tidal power plants operate using a rapidly varying head of water and, therefore, their
turbines must have high efficiency at varying head. The Kaplan type of water turbine operates
quite favourably under these conditions. The propeller type of turbine is also suitable because
the angle of the blades can be altered to obtain maximum efficiency while water is falling.
A compact reversible horizontal turbine has been developed by French Engineer which
acts with equal efficiency both as a pump and as a turbine. The bulb-type turbine (Fig. 1.3)
consists of a steel shell completely enclosing the generator which is coupled to the turbine
runner. The turbine is mounted in a tube within the structure of the barrage, the whole machine
being submerged at all times.

NON-CONVENTIONAL AND CONVENTIONAL SOURCES OF ENERGY

Runner vanes
Metal
casing

Draft tube

Fig. 1.3 Bulb-Type Turbine

When the power demand on the system is low during the rising tides, the unit operates
as a pump to transfer water from sea to the basin. When the load on this system is high, the
unit will work as a generator, and deliver the stored energy which is a valuable additional
input to the system.
There are two tidal power plants in France now in operation; an experimental one with
a capacity of 9 MW at Saint Malo and a 240 MW Plant with a 700 m long dam at the mouth of
the Rance River. A large number of tidal power projects have been planned but subsequently
abandoned because of the high cost involved and obstruction in navigation.
Even though many problems have to be overcome in tidal power development, this form
of power has certain definite advantages. Output of a tidal power station is independent of the
seasonal changes and can be predicted well in advance, as it depends on the cosmic phenomenon.
It is possible to predict the amount of power and the time at which it will be available throughout
the year. This power can, therefore, be utilized at the proper position of the load curve.
More than fifty sites have been identified in the world for possible generation of tidal
power. As more and more technological advancement take place, even more sites could be
identified for tidal power development. Some of the important sites are:
(i) La Rance (France), (ii) Severn Barrage (UK), (iii) White sea (USSR), (iv) Passamaquoddy (USA), (v) Gulf of Cambey (India) and (vi) Gulf of Kutch (India).
The maximum tidal range in the Gulf of Cambey is about 10.8 m and is quite attractive
for a tidal plant. However, the silt charge of the Gulf of Cambey is relatively high and needs a
closer study for further development.
The Gulf of Kutch has a maximum spring tide of 7.5 m and the silt charge is relatively
low.

1.2

WIND POWER

1.2.1 Introduction
The wind wheel, like the water wheel, has been used by man for a long time for grinding corn
and pumping water. Ancient seamen used wind power to sail their ships. With the development
of the fossil fuelled and hydro-electric plants, there was decline in the use of wind power due to

GENERATION, DISTRIBUTION AND UTILIZATION OF ELECTRICAL ENERGY

the less cost involved in the new methods. Another difficulty with wind power was the problem
of energy storage. The energy could not be made available, on demands, due to uncertainties of
wind. Due to these two reasons, no further attempt was made to develop wind power for large
scale power generation.
In recent years, however, as a result of energy crisis in the world, it has been decided to
investigate all possible means of developing power, as alternatives to fuel fired plants. The
wind could supply a significant portion of the worlds energy demand. An estimate by an
American Professor indicates the potentialities of wind power. According to him about 350,000
wind mills each rated for about 1250 KW to 2200 KW could develop power of the order of
190,000 MW. With the advancement in the knowledge of aero-dynamics it has been possible to
build larger and more efficient wind power plants. A typical example is the 1250 KW installation
at Grandpas Knol in U.S.A. Whereas some success has been achieved in developing small and
medium size plants, the prospects of large scale generation i.e., 1 MW or above are not, as yet
very encouraging.
1.2.2 Characteristics of Wind Power
Wind as a source of energy is plentiful, inexhaustible and pollution free but it has the
disadvantage that the degree and period of its availability are uncertain. Also, movement of
large volumes of air is required, to produce even a moderate amount of power. As a result, the
wind power must be used as and when it is available, in contrast to conventional methods
where energy can be drawn upon when required. Wind power, therefore, is regarded as a
means of saving fuel, by injection of power into an electrical grid, or run wind power plant in
conjunction with a pumped storage plant.
The power that can be theoretically obtained from the wind, is proportional to the cube
of its velocity and thus high wind velocities are most important. The power developed using
this law, in atmospheric condition where the density of air is 1.2014 kg/cu metre, is given as
Power developed = 13.14 106 A V 3 KW
where A is the swept area in sq. metre and V the wind velocity in Km/hr. The energy developed
is affected by :
The Altitude of the Site
The velocity of the wind increases with the altitude. In general, the higher the wind
wheel is placed above ground, the greater will be wind power available.
Velocity Duration Curve
The variation of velocity of wind over the period affects the power output, e.g., let the
velocity over the first hour be 30 kmph and the next hour be 20 kmph. The energy developed is
proportional to 303 + 203 = 35,000. On the other hand, if we assume average velocity during
these two hours of 25 kmph, the power developed is proportional to 2 253 = 33250. Thus, the
relation between the actual energy available, and that available from a steady wind of average
velocity, varies considerably and depends on the shape of the velocity-duration curve for the
period of generation.
The wind speeds, between which a wind wheel generator operates, are limited. A certain
minimum wind velocity is required to overcome frictional and other losses of the machine and,

NON-CONVENTIONAL AND CONVENTIONAL SOURCES OF ENERGY

on the other hand, it would be uneconomical to design a plant for very high velocity wind
which would occur only for a small period over the year. Therefore, the machine must be
designed for a rated wind velocity, for which the output is maximum. Typical wind velocities
for some sites may range between 30 kmph to 45 kmph.
The rated wind velocity, for which a plant is designed substantially affects the specific
output (K whr generated per annum per KW installed capacity) and also the cost of construction.
If the rated velocity is low, the specific output is high as full output will be generated for a
relatively longer duration of the year, whereas if the rated velocity is high, the converse will be
true. But with low rated wind velocity, a larger diameter wheel will be required for a given KW
rating, which in turn increases the cost of the plant. Economic development of wind power,
therefore, requires selection of sites where high specific outputs are compatible with reasonable
cost of construction of plant. It is, therefore, necessary to obtain wind velocity duration curve
for a particular site and to know the output of the machine for varying wind velocities. The
maximum efficiency of the wind power plant is found not to exceed 40%.
1.2.3 Design of Wind Wheels
Several types of wind wheels have been used but the advantage of propeller rotating
about a horizontal shaft, in a plane perpendicular to the direction of the wind make it the most
likely type to realise economic generation on a large scale. A propeller consisting of two or
three blades (with an aerofoil section) and capable of running at the high speeds is likely to be
the most efficient. Present technology has been able to build systems with 60 m long blades, on
towers as high as 305 m. A large tower system, to support many small rotor-generator units,
can also be built.
Wind pressure rotates the wind vanes or propellers attached to a shaft. The revolving
shaft rotates the rotor of a generator, through a mechanism of gears couplings etc. Thus,
electricity is generated.
The wind power plants can be operated in combination with steam or hydro power station,
which will lead to saving in fuel and increase in firm capacity, respectively of these plants.
Wind energy can prove to be a potential source of energy for solving the energy problem.
It can certainly go a long way to supply pollution-free energy to millions of people, living in the
villages all over the world.
The economic viability of wind mills is better in situations where conventional
transmission costs are extremely high (because of inaccessiability and small load) or where
continuous availability of supply is not essential so that only a limited amount of storage on
standby power need be provided.

1.3

GEOTHERMAL POWER

1.3.1 Introduction
Many geothermal power plants are operating throughout the world. Although larger geothermal
power plants are in operation in America today, it is to the credit of the Italians that the first
impressive breakthrough in geothermal power exploitation was achieved. The oldest geothermal

10

GENERATION, DISTRIBUTION AND UTILIZATION OF ELECTRICAL ENERGY

power station is near Larderello in Italy, which has an installed capacity of 380 MW. In
Newzealand geothermal power accounts for 40% of the total installed capacity, whereas in
Italy it accounts for 6%.
It is a common knowledge that the earths interior is made of a hot fluid called magma.
The outer crust of the earth has an average thickness of 32 Km and below that, is the magma.
The average increase in temperature with depth of the earth is 1C for every 35 to 40 metre
depth. At a depth of 3 to 4 Kms, water boils up and at a depth of about 15 Kms, the temperature
is, in the range of 1000C to 1200C. If the magma finds its way through the weak spots of the
earths crust, it results into a volcano. At times, due to certain reasons the surface water
penetrates into the crust, where it turns into steam, due to intense heat, and comes out in the
form of springs or geysers. Moveover, the molten magma also contains water, which it releases
in the form of steam, which could be utilized for electric power generation.
1.3.2 Principle of Operation
Various types of cycles have been suggested for geothermal power generation. Only two
important ones, which are being used in practice, are discussed here.
Indirect Condensing Cycle
While developing Larderello power plant, it was thought, that geothermal steam may
corrode the turbines. Therefore, an indirect system was adopted, which involved the use of a
heat exchanger by means of which clean steam was raised from contaminated natural steam
(Fig. 1.4). In spite of the fact that about 15% to 20% of the steam power potential had to be
sacrificed in the heat exchanger, the cycle was considered economical, because of the recovery
of minerals and non-condensible gases from the new steam.
G
Hx
C
BS
P

CCooling water
BSBore steam
PPump
HxHeat exchanger
DDegasifier
ggases discharged
mmineralised water
wwaste water
BBarometer pipe

gmw
(a)

Fig. 1.4 Indirect Condensing Cycle

With the advancement in metallurgy technology and the declining economic attractions
of mineral extraction, through this process, this cycle has been rendered obsolete.
Direct Non-Condensing Cycle
This is the simplest, cheapest and most widely used geothermal cycle. Bore steam, either
direct from dry bores, or after separation (using centrifugal separator) from wet bores, is simply
passed through a turbine and exhausted to atmosphere (Fig.1.5).

NON-CONVENTIONAL AND CONVENTIONAL SOURCES OF ENERGY

11

BSBore steam
XExhaust
GGenerator

BS

Fig. 1.5 Direct Non-Condensing Cycle

There is a need for utilizing the heat available from the high temperature (about 1000C)
layers of the earth. It has been suggested that water should be pumped into artificial volcanic
craters and then turned into useful steam.
Like hydro power stations, geothermal power plants are unattended and do not need
full time supervision. Since the units are unattended, the warning alarm can be transmitted to
the attended station where appropriate action can be taken.
If a well has been shut down, it requires several hours to get it upto rated flow to clear
it of water and debris. Some more time is required to warm up the steam collection system
piping the drain condensate from it. No attempt should be made to fast start ups as it results
in damage to the turbine blades. Steam temperature and steam line drains should be closely
monitored, for any indication of water. If there is any possibility of water coming alongwith
the steam, the unit should be tripped to prevent damage to the turbine. Rated turbine throttle
pressure is maintained by connecting sufficient number of wells to the supply line of a unit.
Whenever a unit trips, the steam should be released to the atmosphere. If a unit is to be shut
down for a long time, the wells should also be shut down.
It is important that a systematic schedule of preventive maintenance be observed at
these plants. A rigidly planned periodic maintenance schedule must be adhered to. Units should
be inspected every three years. An adequate stock of spare partsespecially the turbine blades
must be maintained. With proper maintenance, it is possible to operate these plants at very
high annual plant load factor of the order of 90% or even more.
1.3.3 Combined Operation of Geothermal Plant
It is well known that a composite power system can be supplied more economically by a
combination of two main types of plants:
(i) Base Load Plant which is characterised by high fixed cost and low variable cost.
(ii) Peak load Plant which is characterised by low fixed cost and high variable cost.
In case of a geothermal plant, the usual practice is to regard all the production cost as
fixed cost, with zero variable cost as no fuel is required for its operation. This is justified by the
fact, that once geothermal steam has been made available by means of capital spent on
exploitation, drilling and pipe work, it may be regarded as free. Geothermal plants are, therefore,
ideally rated as base load plants. Most of the plants today are being used as base load plants as
they can achieve annual plant load factor of 90% or morehigher than that obtainable from
thermal or nuclear plant.

12

GENERATION, DISTRIBUTION AND UTILIZATION OF ELECTRICAL ENERGY

The commercial viability of a geothermal power plant as compared to other sources,


depends upon the cost of alternative power sources and other local factors. As a rule of thumb,
the following guidelines may be followed to assess its viability:
(i) The fluid temperature at the bottom of the bore should be at least 180C.
(ii) A temperature of 180C should be available at depths not exceeding 3 Kms.
(iii) The yield from a 24 1/2 cm bore should be at least 20 tons/hr of steam.
The following are some of the geothermal power projects in operation :
Larderello

Italy

Geysers

California (USA)

Cerro Prieto

Mexico

Hatchobaru

Japan

Matsukawa

Japan

Paratunka

USSR

Wairakei

New Zealand

Pugga Multipurpose

India

Project (Ladakh)
At present geothermal energy makes a very small, but locally important, contribution
to world energy requirements. This situation will not change unless important technological
advances are made. Environmentally, it is probably the least objectionable form of power
generation available at present, with, the exception of hydroelectric methods.

1.4

WAVE POWER

1.4.1 Introduction
Another source of non-conventional energy generation is the wave power. The major
problem with the wave power is that it is not concentrated at a place. If means could be developed
for collecting the energy in the wave, spread over a large surface area, and concentrating it
into a relatively small volume, the prospects, would be considerably improved.
It has been observed that a typical wave measures 2 to 3 metres in height throughout
the year. The energy per square metre of wave surface area is given as 1/2 ga2 where is
density of sea water, g is acceleration due to gravity and a is the amplitude of the wave. In the
Atlantic, the wave period T is around 9s, and the average velocity of propagation of wave is 14
m/s. It has been observed that a power flow of around 70 KW for every metre of wave front, can
be obtained. This is a considerable amount of power, especially when we think of the availability
of this power throughout the year. If the length of the coast line is, say 1200 Km, the power
available is around 84 GW.
1.4.2 Wave Power Conversion Devices
A large number of devices for converting wave power to mechanical power have been
suggested in the literature e.g. flaps, ramps, floats and converging channels.

13

NON-CONVENTIONAL AND CONVENTIONAL SOURCES OF ENERGY

A device known as Salter Cam is being used for this purpose which has a high efficiency
(75%). A cross section of the device is shown in Fig. 1.6. It simulates the action of a vertical
flapping plate at the front where energy is absorbed, but the rear is cylindrical so that the
water beyond the device is not disturbed, as it rotates. Due to its asymmetrical shape, the
response of this device depends upon its loading and therefore, counter-balancing is necessary.

Balancing float
300

Principal
wave direction

Independently
oscillating cam-shaped floats

Continuous
central core
houses
pumps etc.

Fig. 1.6 Salter Cam

Another device suggested by Masuda uses a bell shaped chamber filled with air, which
is pumped through an air turbine by the rising and falling motion of the water. A large number
of such devices are in use, for providing about 60 watt of power for marine buoy lights. Such
devices are inherently small in size, but a large number of them could be put together, to
provide a large floating structure e.g. an arrow-shaped triangular structure (Fig. 1.7) for
mounting, near the shore.

Fig. 1.7 Masuda System of Floating Buoys

Wave power, even though looks to be a single component, but it must be considered in
its entirety if it has to make significant contributions. Fig. 1.8 shows various possible ways in
which wave power can be used and shows the various links between the sea-waves and the
consumer of power.
If the wave power is to be brought off-shore as electrical power, a submarine cable will
be required. In recent times a lot of technological developments have taken place in the design

14

GENERATION, DISTRIBUTION AND UTILIZATION OF ELECTRICAL ENERGY

and manufacture of submarine cables and it should not be a problem to produce economical
submarine cables. A variable frequency generator could feed a rectifying device. The power
could be transmitted through the cable to the substation. It could then be inverted and fed into
a grid system. Alternatively, the power could be used on-board floating factories. Also, hydrogen
could be produced by the d.c. output which could be supplied to the consumer as fuel.
Wave energy
source

Devices

Direct electrical
generation

Floating factory
direct use
on board

Pump loading
Hydraulic
system

Turbogenerator

Electrical S/S
Transmission
ashore
electrical

Manufacture
secondary
fuels e.g. H2

Transmission
ashore
hydraulic
Storage
Turbogenerator

Electrical
grids

Storage or
stand by plant

Electricity
consumer

Fuel
consumer

Manufacture
secondary
fuels e.g. H2

Fig. 1.8 Use of Wave Power

Another possibility is that the energy could be transmitted hydraulically, using a storage
system to provide short term storage before transfer to a turbo-generator. The conversion
equipment would be inside the cams and the electricity outputs connected to a floating substation
by cable.

1.5

MAGNETO HYDRO DYNAMIC (MHD) GENERATION

1.5.1 Introduction
In the conventional steam power plants, the heat released by combustion of fuel is
transformed into the internal energy of steam. The temperature and pressure of steam increase
in the process. The steam turbine, then, converts steam energy into mechanical energy, which
drives a generator. This way, the mechanical energy is converted into electric energy. The
repeated conversion of various forms of energy involves losses and, hence, the overall efficiency

15

NON-CONVENTIONAL AND CONVENTIONAL SOURCES OF ENERGY

of thermal power plant decreases. The typical range of effciency of thermal plants is 37 to 40%.
The direct conversion of heat to electricity would enable the industry to use the fuel resources
more efficiently. MHD generation is one form of energy technology, wherein direct conversion
of heat into electric energy has been devised. The technological development in the field of
plasma physics and metallurgy etc. and other branches of science and technology has made it
possible for this kind of direct transformation of energy.
An ionized gas is used as conducting medium in the MHD generator. The gas can be
made electrically conducting when it is maintained at least at a temperature of 2000C. This
fact does not allow MHD generation from being used in the entire temperature range from
3000 K to 300 K. It is therefore, thought beneficial that MHD generators be used in conjunction
with steam operated thermal plants utilising the heat of the gas leaving the MHD ducts. The
combined operation of MHD generators alongwith the conventional thermal plant, will raise
the overall efficiency to nearly 60%, thereby lot of saving in the fuel cost will result.
1.5.2 Principle of Operation of MHD Generator
The basic principle of operation is based on Faradays law of electro magnetic induction,
which states an e.m.f. is induced in a conductor moving in magnetic field. The conductor may
be a soild, liquid or a gaseous one. The study of the dynamics of an electrically conducting fluid
interacting with a magnetic field, is called magneto hydro dynamics.
In this method (Fig. 1.9) gases at about 2500C are passed through the MHD duct across
which a strong magnetic field has been applied. Since the gases are hot, and partly ionized
they form an electrically conducting conductor moving in the magnetic field. An e.m.f. (directcurrent) is thus induced, which can be collected at suitable electrodes.
Anode
Gas flow
Load
Flow
out
Magnetic
field B
Cathode

Fig. 1.9 Basic Principle of MHD Generator

Block diagram of a typical open cycle MHD power plant is shown in Fig. 1.10.

1.6

SOLAR ENERGY

1.6.1 Introduction
Sun is the primary source of energy. The earth receives 1.6 1018 units of energy from
the Sun annually, which is 20,000 times the requirement of mankind on the earth. Some of the
solar energy causes evaporation of water, leading to rains and creation of rivers etc. Some of it

16

GENERATION, DISTRIBUTION AND UTILIZATION OF ELECTRICAL ENERGY

is utilized in photosynthesis which is essential for sustenance of life on earth. Man has tried,
from time immemorial, to harness this infinite source of energy, but has been able to tap only
a negligibly small fraction of this energy, till today.
Seed

Fuel
+
Seed

Electromagnet

Air

Air preheater
and seed
recovery

MHD
Duct

Boiler

Super Re
heater heater

Diffuser
Combustion
chamber

Inverter

Generator
Output
to grid

Air
compresser

HP
turbine

LP
turbine
Condenser

Air in

Fig. 1.10 Block Diagram of Open Cycle MHD Power Station

Three broad categories of possible large scale applications of solar power are:
(i) The heating and cooling of residential and commercial buildings;
(ii) The chemical and biological conversion of organic material to liquid, solid and gaseous
fuels; and
(iii) Conversion of solar energy to electricity.
The use of solar energy for generation of electricity is costly as compared to conventional
methods. However, due to scarcity of fuel, solar energy will certainly find a place in planning
the national energy resources.
1.6.2 Residential cooling and heating
A major component of our electricity bill is due to heating and cooling of buildings. This
can be achieved using solar energy. A typical solar energy scheme is shown in Fig. 1.11. A flat
plate collector is located on the roof of a house, which collects the solar energy. The cooling
water is pumped through the tubes of the solar collector. The heat is transferred from the
collector to the water and the hot water is stored in a storage tank which may be located at
ground level or in the basement of the house. Hot water is then utilized to heat or cool the
house by adjusting the automatic valve. A separate circuit is there to supply hot water. Thus
all the three requirements i.e., space cooling, heating and water heating are met.

17

NON-CONVENTIONAL AND CONVENTIONAL SOURCES OF ENERGY

lar
So tion
ia
rad

Winter
operation

(Used only when


solar is not
available)
Auxiliary
heater

Solar
collector
Hot
water

Cool
water

Summer
operation

Hot water
(Winter) (Summer)
Warm air Cool air

Air
heating
unit

Absorption
air cool unit

Hot water
storage tank
Cool
water
return
Pump

Warm
water
Air blower return

Pump

Fig. 1.11 Schematic Diagram of Residential Cooling and Heating with Solar Energy

1.6.3 Photosynthesis Production of Energy Sources


Solar energy can be transformed into chemical energy in the form of plants and trees,
through the process of photosynthesis, which is the basis of the worlds fossil fuels. It is, now
possible, to produce organic matter with high heat content, by using suitable chemical processes.
1.6.4 Solar Power Plant
It is known that only a small fraction of the energy radiated by the Sun reaches the
Earth. It would, therefore, be an attractive proposition, if energy could be received from outside
the atmosphere and then transmitted to the earth. A man-made satellite revolving around the
earth will receive energy for all the 24 hours and will not be affected by the weather conditions.
Fig. 1.12 shows the arrangement and general view of a solar power plant, carried by a
man-made satellite. The solar cell panels to be installed on the satellite may vary in area from

SUN

Sync

hron
of sa ous orb
it
tellite

Transmitting
antenna

Earth

2-3 GHz
Solar cell panels

Fig. 1.12 Solar Power Plant

Receiving
antenna

18

GENERATION, DISTRIBUTION AND UTILIZATION OF ELECTRICAL ENERGY

16 to 100 sq km according to the plant capacity. The solar cells arranged in space would generate
d.c. electric power and transmit it by means of microwaves (of about 10 cm. wave length),
using a transmitting antenna. Microwave transmission may be at 2 to 3 GHz, as this keeps the
losses at minimum. On the earth, this energy will be converted into high voltage d.c. or
commercial frequency electric power.
The diameter of transmitting antenna would be around 1 km and that of the receiving
antenna, 7 to 10 Kms. The effeciency of transmission is estimated to be in the range of 55 to
75%. The overall efficiency, with the present technology, is around 25% but is likely to go upto
60% in the near future.
The solar cells operate on the principle of photo electricity i.e., electrons are liberated
from the surface of a body when light is incident on it. Backed by semi-conductor technology, it
is now possible to utilize the phenomenon of photo-electricity.
It is known that if an n-type semi-conductor is brought in contact with a p-type material,
a contact potential difference is set-up at the junction (Schottky effect), due to diffusion of
electrons. When the p-type material is exposed to light, its electrons get excited, by the photons
of light, and pass into the n-type semi-conductor. Thus, an electric current is generated in a
closed circuit. The pn junction silicon solar cells have emerged as the most important source of
long duration power supply necessary for space vehicles. These cells are actuated by both,
direct Sun rays and diffuse light. The efficiency of silicon solar cells increases with decreasing
temperature. In cold weather the decreased luminous flux is compensated for, by higher
efficiency. The efficiency of these solar cells varies from 15 to 20%.
Although the energy from the Sun is available free of cost, the cost of fabrication and
installation of systems, for utilization of solar energy, is often too high to be economically
viable. In order to make solar installations economically attractive, plastic materials are being
increasingly used for the fabrication of various components of the system.
The efficiency of solar heating/cooling installation depends on the efficiency of collection
of solar energy and its transfer to the working fluid (e.g. water, air etc.). There are two main
classes of collectors. The flat plate collector is best suited for low and intermediate temperature
applications (4060, 80120C) which include water heating for buildings, air heating and
small industrial applications like agricultural drying etc. The concentrating collectors are
usually employed for power generation and industrial process heating.
1.6.5 Solar Concentrators
Solar concentrators are the collection devices which increase the flux on the absorber
surface as compared to the flux impinging on the concentrator surface. Optical concentration
is achieved by the use of reflecting refracting elements, positioned to concentrate the incident
flux onto a suitable absorber. Due to the apparent motion of the Sun, the concentrating surface,
whether reflecting or refracting, will not be in a position to redirect the sun rays onto the
absorber, throughout the day if both the concentrator surface, and absorber are stationary.
Ideally, the total system consisting of mirrors or lenses and the absorber should follow the
Suns apparent motion so that the Sun rays are always captured by the absorber. In general, a
solar concentrator consists of the following:
(i) a focussing device;

NON-CONVENTIONAL AND CONVENTIONAL SOURCES OF ENERGY

19

(ii) a blackened metallic absorber provided with a transparent cover; and


(iii) a tracking device for continuously following the Sun.
Temperatures as high as 3000C can be achieved with such devices and they find
applications in both photo-thermal and photo-voltaic conversion of solar energy. The use of
solar concentrators has the following advantages:
(i) Increased energy delivery temperature, facilitating their dynamic match between
temperature level and the task.
(ii) Improved thermal efficiency due to reduced heat loss area.
(iii) Reduced cost due to replacement of large quantities of expensive hardware material
for constructing flat plate solar collector systems, by less expensive reflecting and/or
refracting element and a smaller absorber tube.
(iv) Increased number of thermal storage options at elevated temperatures, thereby
reducing the storage cost.
Parameters Characterising Solar Concentrators
Several terms as used to specify concentrating collectors. These are:
(i) The aperture area is that plane area through which the incident solar flux is accepted.
It is defined by the physical extremities of the concentrator.
(ii) The acceptance angle defines the limit to which the incident ray path may deviate,
from the normal drawn to the aperture plane, and still reach the absorber.
(iii) The absorber area is the total area that receives the concentrated radiation. It is the
area from which useful energy can be removed.
(iv) Geometrical concentration ratio or the radiation balance concentration ratio is defined
as the ratio of the aperture area to the absorber area.
(v) The optical efficiency is defined as the ratio of the energy, absorbed by the absorber,
to the energy, incident on the aperture.
(vi) The thermal efficiency is defined as the ratio of the useful energy delivered to the
energy incident on the aperture.
Solar concentrators may be classified as point focus or line focus system. Point focus
systems have circular symmetry and are generally used when high concentration is required
as in the case of solar furnaces and central tower receiver systems. Line focus systems have
cylindrical symmetry and generally used when medium concentration is sufficient to provide
the desired operating temperature.
A solar concentrator consists of the following components:
(i) A reflecting or refracting surface, (ii) An absorbing surface i.e., an absorber, (iii) A
fluid flow system to carry away the heat, (iv) a cover around the absorber, (v) Insulation for the
unirradiated portion of the absorber and (vi) A self supporting structural capability and well
adjusted tracking mechanism.
1.6.6 Flat Plate Collector
The schematics of a flat plate collector are shown in Fig. 1.13. It usually consists of five
main components viz.

20

GENERATION, DISTRIBUTION AND UTILIZATION OF ELECTRICAL ENERGY

(i) an absorber plate (metallic or plastic),


(ii) tubes or pipes for conducting or directing the heat transfer fluid,
(iii) one or more covers,
(iv) insulation to minimise the downward heat loss from the absorbing plate,
(v) casing which encloses the foregoing components and keeps them free of dust and
moisture and also reduces the thermal losses.
Generally flat plate collectors are framed sandwich structures, mounted on roofs or
sloping walls. In most of these collectors, the absorber element is made of a metal such as
galvanised iron, aluminium, copper etc. and the cover is usually of glass of 4 mm thickness.
The back of the absorber is insulated with glass wool, asbestos wool or some other insulating
material. The casing, enclosing all the components of the collector is either made of wood or
some light metal like aluminium. The cost, with such meterials, is rather too high to be
acceptable for common use. As the temperatures needed for space heating are rather low,
plastics are being considered as potential material for fabrication of various components of the
flat, plate collector. This would make solar energy systems comparable with other energy
systems.
Transparent
covers

Absorbing
surface

Direct-solar
radiation

Fluid tubes
Insulation

Fig. 1.13 Schematics of a Flat Plate Solar Collector

1.7

CONVENTIONAL SOURCES

1.7.1 Hydro Station


The water wheel, as developed in the early part of 19th century, played an important
role in converting water power into mechanical power. With the invention of steam engines,
the use of water wheel began to decrease and larger steam engines were developed. Steam
engines possessed the advantage of mobility, allowing power to be produced, where it was
required and also that of flexibility in its application.
It was only later with the discovery of conversion of mechanical energy into electric
energy, and transmission of electric energy being the most efficient method of transporting
energy from one place to another, that water wheel was revived. The modern water turbine, is
being built in single unit of more than 200 MW. Also, the concept multipurpose project, in
which the production of power is included as one of several uses (flood control, navigation,
irrigation, water for domestic and industrial purpose, etc.), has led to the development of sites
which otherwise could not be harnessed economically for power alone. The capital investment

NON-CONVENTIONAL AND CONVENTIONAL SOURCES OF ENERGY

21

per KW is much higher in case of hydro power as compared to thermal power. This is because
in order to store water at sufficient head, it is essential to construct a dam which is a costly
affair. However, the running cost of hydro electric energy is much less as no fuel is used.
Water power differs fundamentally from thermal power in that it represents an
inexhaustible source of energy which is continually replenished by the direct agency of the
Sun; whereas thermal power represents chemical energy which has been created and stored
within the earths crust during past geological ages. The use of chemical energy is thus equivalent
to the consumption of capital as the replacement is not so easy. Another important difference
between the two is that whereas water power can be developed only where it is present in
nature, thermal power (liquid or solid fuel) can be transported for use from one place to another.
1.7.2 Selection of Site
Preliminary investigation regarding catchment area, average rainfall, ground gradient,
geology of foundation, availability of raw material for construction work are required. The
important factors governing selection are as follows:
1. Location of Dam
From the cost point of view smaller the length of dam, the lower will be the cost of
construction. Therefore, the site has to be where the river valley has a neck formation. In
order to have capacity, a valley which has a large storage capacity on the upstream side of the
proposed dam site is probably the best. It is desirable to locate a dam after the confluence of
two rivers so that advantage of both the valleys to provide larger storage capacity is available.
2. Choice of Dam
The most important consideration in the choice of the dam is safety and economy. Failure
of a dam may result in substantial loss of life and property. The proposed dam must satisfy the
test of stability for : (i) shock loads which may be due to earthquakes or sudden changes in
reservoir levels and (ii) unusually high floods.
The dam should, as far as possible, be close to the turbines and should have the shortest
length of conduit.
3. Quantity of Water Available
This can be estimated on the basis of measurements of steam flow over as long a period
as possible.
Storage of water is necessary for maintaining continuity of power supply thoughout the
year. Sufficient storage of water should be available since rainfall is not uniform thoughout
the year and from one year to another.
4. Accessibility of Site
The site should be accessible from the view point of transportations of man and material,
so that the overall cost for construction, of project is kept low.
5. Distance from the Load Centre
The distance should be as small as possible so that the cost of transmission of power is
minimum.
Availability of construction material and general knowledge, should also be considered
in site selection.

You might also like