CSSR PS Degradation Due To Other Congestion (Huawei)

The site JAJARSOLOMW was experiencing degradation of CSSR PS due to increasing other congestion. Analysis found unbalanced CPU board loads between the two WBBP boards at the site. Configuring the UL and DL groups for the underutilized WBBP board helped balance the loads and resolved the CSSR and congestion issues.

Uploaded by

bluebird1969
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
411 views9 pages

CSSR PS Degradation Due To Other Congestion (Huawei)

The site JAJARSOLOMW was experiencing degradation of CSSR PS due to increasing other congestion. Analysis found unbalanced CPU board loads between the two WBBP boards at the site. Configuring the UL and DL groups for the underutilized WBBP board helped balance the loads and resolved the CSSR and congestion issues.

Uploaded by

bluebird1969
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 9

CSSR PS degradation due

to Other Congestion
(Huawei)
[email protected]
[email protected]
[email protected]

Main Problem

Highlight :
Site JAJARSOLOMW all sectors, have degradation of CSSR PS, follow by
increments of Other Congestion

Nexwave Design and Strategic

Page 2

Analysis
RNC XPU Load
Highlight :
JAJARSOLOMW located at RNC SOLO
- XPU SRN=2,SN=2,SSN=1
XPU Load RNC SOLO
SRN=2,SN=2,SSN=1 decreased on 12
Sept 2013,
For this case on JAJARSOLOMW, If
We compare XPU Load RNC SOLO
SRN=2,SN=2,SSN=1 and Rejection
due to Other Congestion at
JAJARSOLOMW not in-line. Might be
problem in NodeB board or other
possibility

Nexwave Design and Strategic

Page 3

Analysis
NodeB Board Configuration

CPU Board Load

Nexwave Design and Strategic

Highlight :
Base on NodeB Board Configuration,
JAJARSOLOMW have 2 WBBP. These 2
WBBP located at CN=0,SRN=0,SN=1 and
CN=0,SRN=0,SN=3
Base on CPU Board Load, we found
unbalance CPU Board Load, CPU Board
Load of
WBBP CabinetNo=0,SubrackNo=0,SlotNo
=3 reach 90%, and CPU Board Load of
WBBP CabinetNo=0,SubrackNo=0,SlotNo
=1 is 0%
Proposed to rebalance CPU Board Load of
WBBP

Page 4

Action
Check UL Group at NodeB MML Command

Highlight :
After check WBBP board
CabinetNo=0,SubrackNo=0,SlotNo=1
already configured properly, check
Board sharring status.
Base on NodeB MML Command, We
found ULGROUP for WBBP board
CabinetNo=0,SubrackNo=0,SlotNo=1
not configured
Proposed to add ULGROUP for
WBBP board
CabinetNo=0,SubrackNo=0,SlotNo=1

Nexwave Design and Strategic

Page 5

Action
Check DL Group at NodeB MML Command

Highlight :
Base on NodeB MML Command, We
found DLGROUP for WBBP board
CabinetNo=0,SubrackNo=0,SlotNo=1
not configured
Proposed to add DLGROUP for
WBBP board
CabinetNo=0,SubrackNo=0,SlotNo=1

Nexwave Design and Strategic

Page 6

Result

Highlight :
CPU WBBP Board Load already
balanced
Rejection due to Other Congest
already disappear and CSSR PS
JAJARSOLOMW improved

Nexwave Design and Strategic

Page 7

Conclusion

Conclusion
Rejection due to Other Congest already disappear and CSSR PS JAJARSOLOMW
improved after to rebalance CPU Board Load of WBBP.