Grilles, Louvres, Diffusers & Air Valves
Grilles, Louvres, Diffusers & Air Valves
I the
Description
Quality
Construction
Finish
Fixing
Packaging
Options
30mm FACE
BORDER
Ordering Procedure
67mm
Technical Data
OP T.
OBD
NOMINAL + 44mm
NOMINAL + 44mm
30mm FACE
BORDER
30mm Face
90mm
Free Area:
Approx 90%.
68mm
Nominal Size D
OPTIONAL
OPPOSED
BLADE
46mm
DAMPER
OPTIONAL
OPPOSED
BLADE
DAMPER
23mm
67mm
OP T.
OBD
22mm
Fixing
Packaging
Construction
Options
Size Range
Ordering Procedure
OPTIONAL
OPPOSED BLADE
DAMPER
6mm
64mm
108mm
DIMENSION A
38mm
Actual Neck
Dimension A
Minimum Opening
Dimension B
OverallFlanges
Dimension C
150 x 150
146 x 146
228 x 288
290 x 290
225 x 225
223 x 223
305 x 305
367 x 367
300 x 300
299 x 299
381 x 381
443 x 443
375 x 375
375 x 375
457 x 457
519 x 519
450 x 450*
451 x 451
533 x 533
595 x 595
DUCT SIZE
CM
600 x 600
D
152, 203
254, 305
356, 381
59
10
500 x 500
152, 203,
254
57
11
300 x 300
127, 152
178, 203
25
16
Size
6
8
10
12
15
18
21
A
152
203
254
308
381
457
634
B
C
305 340
407 457
508 569
610 680
762 851
914 1041
1080 1148
D
51
64
86
95
121
146
178
E
5
6
5
6
6
-
F
110
127
146
155
172
248
280
G
320
430
530
640
800
950
1100
67mm
OPTIONAL
OPPOSED
BLADE
22mm DAMPER
80mm
40mm
30mm
50mm
38mm
50mm
Free Area:
Approx 50%.
Free Area:
Approx 50%.
Construction
Construction
Sizes
Sizes
D (mm)
d (mm)
Weight (g)
KSU 100
130
300
KU 80
110
130
KU 100
130
190
KU 125
160
270
KU 150
188
360
KU 160
190
380
KU 200
245
580
KSU 125
160
390
KSU 150
188
520
KSU 160
190
520
KSU 200
235
780
D (mm)
d (mm)
Weight (g)
Model KSUB is a
combination fire damper
and air valve for exhaust
air ventilation systems.
The damper blade will
close when the
temperature in the vicinity
of the valve reaches the
fusible link rating standard temperature
70C. (Alternative release
temperatures of 50C and
100C available to special order).
Adjustment of the airflow is simple, the inner cone
being rotated to the required setting and locked in
position with a single nut. Each air valve is supplied
complete with a mounting ring from which it can be
simply removed for cleaning without affecting the setting
of the valve.
Construction
Sizes
The Model KSUB is manufactured in five sizes, 100,
125, 150, 160, and 200mm (external diameter of
mounting ring).
D (mm)
d (mm)
Weight (g)
D (mm)
d (mm)
Weight (g)
KI 80
111
140
KSUB 100
130
320
KI 100
130
210
KI 125
160
300
KSUB 125
160
420
KI 150
190
390
KSUB 150
188
560
KI 160
190
410
KSUB 160
190
560
KI 200
245
650
KSUB 200
235
810
B + 30
47
A + 70
AxB
Description
AxB
Construction
Model References
RGS-1
RGS-7
A x B = Cutting Dimension
47
Fixing
Ordering Procedure
325 x 75
325 x 150
325 x 225
525 x 75
525 x 150
525 x 225
825 x 75
825 x 150
825 x 225
1025 x 75
1025 x 150
1025 x 225
Minimum
Duct
Diameter
160
315
500
160
315
500
160
315
500
160
315
500
Free are
(M3)
0.017
0.034
0.056
0.028
0.056
0.093
0.045
0.093
0.18
0.056
0.112
0.224
Dimension
C
(RGS-7)
106
106
106
126
126
126
151
151
151
186
186
186
LINDAB Ltd
Cardiff
Exeter
Gateshead
Glasgow
High Wycombe
Kent
02920 794503
01626 835032
0191 482 5995
0141 419 3800
01494 463490
01474 579800
Leeds
Leicester
Lincoln
Manchester
Norwich
Nottingham
Sheffield
Southampton
Stoke-on-Trent
Every effort is made to ensure that the information contained in Lindab literature, drawings and correspondence is accurate, but no
warranty is given in this respect and the Company shall not be liable as a result of any inaccuracy. The Company reserve the right to
alter at anytime, without prior notice, the design, specification, packaging or price of any article and without incurring any obligation.
Ref: 181-2/0312