Preparatory Guidebook For Comprehensive Examination: Question Bank Control Systems

This document provides a preparatory guidebook with questions related to control systems. Some key points covered include: 1) Noise and disturbances can be injected into control systems through various inputs. 2) A control system with a unit transfer function in its feedback loop is called unity feedback. 3) A single-loop feedback control system is called a single-input, single-output (SISO) system. 4) A control system where the output is connected to the input is known as a feedback control system.

Uploaded by

Mohammad Ahmed
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
38 views1 page

Preparatory Guidebook For Comprehensive Examination: Question Bank Control Systems

This document provides a preparatory guidebook with questions related to control systems. Some key points covered include: 1) Noise and disturbances can be injected into control systems through various inputs. 2) A control system with a unit transfer function in its feedback loop is called unity feedback. 3) A single-loop feedback control system is called a single-input, single-output (SISO) system. 4) A control system where the output is connected to the input is known as a feedback control system.

Uploaded by

Mohammad Ahmed
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 1

Preparatory Guidebook for Comprehensive Examination

QUESTION BANK
CONTROL SYSTEMS
Noise is injected through _____________in a control system
Disturbance in injected through _____________in a control system
If transfer function of feed back loop of a control is 1 at its is called____________.
Feed Back control system consisting of single loop is called _____________
A control system in which output is connected to the input is known as ___________
Name practical implementation of feed forward control system _________
In s-domain poles of a control system lies at +3 & +4 the system will be ______
In z-domain if the pole of the system lies inside the unit circle the system will be ________
What is the technique used to find gain and phase margin______________
If the sign of the extreme left row in Routh-Hurwitz remain same the system will be ____________
Routh-Hurwitz criterion is used to find _____________ for which the system remain stable.
In state space if input matrix have one Colum and out put matrix have one row the system will be
__________.
Eigen values defines the ___________ of system.
In root locus technique at K=0 close loop poles are ____________ to open loop poles.
The transfer function of a feed back control system is generalized as _____________
Effect of adding a zero to the forward path transfer function is to increase the _____________ of a
closed loop system.
If the poles of the system are on the imaginary axis the system is said to be _______.