Desuperheater Sizing Calculation
Desuperheater Sizing Calculation
Qty:
Lead Time:
Rev:
Cv: 0.550
Pipe Wall Thickness: 0.432 in
Recommended Mesh Size: 30
kg/cm2g
deg C
kg/cm2g
deg C
Units
30
250
29.04
102
NORMAL
kg/cm2g
deg C
kg/h
deg C
kg/cm2g
deg C
22
240
36531
224.2
29.04
102
22
240
54852
224.2
29.04
102
SIZING CALCULATION
Water Mass Flow
Water Volumetric Flow
Mainline Steam Outlet Mass Flow
Mainline Steam Inlet Velocity
Mainline Steam Inlet Speed of Sound
Throat Velocity
Mainline Steam Outlet Velocity
Water Pressure Drop - DSH
% Spraywater
Water Pressure Drop - SWV
Water Valve Cv
kg/h
gpm(US)
kg/h
ft/s
ft/s
ft/s
ft/s
kg/cm2
%
kg/cm2
705.876
3.246
37236.876
187.55
1723.28
253.02
181.85
2.3
1.93
4.7
0.389
1059.886
4.874
55911.886
281.61
1723.28
379.91
273.05
5.3
1.93
1.7
0.957
kg/h
kg/h
gpm(US)
ft/s
kg/cm2
kg/cm2
6322.340
122.164
0.562
32.46
0.1
7.0
0.055
6322.340
122.164
0.562
32.46
0.1
7.0
0.055
Btu/lbm
Btu/lbm
Btu/lbm
lb/ft3
lb/ft3
1231.6
1211.7
184.7
0.659
0.693
0.958
15.8
38.5
10.0
1231.6
1211.7
184.7
0.659
0.693
0.958
15.8
38.5
10.0
THERMODYNAMIC PROPERTIES
Mainline Steam Inlet Enthalpy
Mainline Steam Outlet Enthalpy
Water Enthalpy
Mainline Steam Inlet Density
Mainline Steam Outlet Density
Water Specific Gravity
Water Saturation Pressure
Mainline Steam Inlet Superheat
Mainline Steam Outlet Superheat
psia
deg F
deg F
MAXIMUM