0% found this document useful (0 votes)
192 views3 pages

API Standard Storage Tank Data Sheet Rev 0

This document is a data sheet for an API Standard 650 storage tank containing information about the tank specifications, construction details, and appurtenances. Key details include: - The tank will have a nominal capacity of XX m3 located at a plant in XX. - It will be constructed of steel with XX number of shell courses and roof/bottom plates of varying thicknesses. - The tank will have features like a bolted door sheet, internal piping, and manholes/nozzles on the shell and roof. - Construction and welding details are provided along with coating and inspection requirements.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
192 views3 pages

API Standard Storage Tank Data Sheet Rev 0

This document is a data sheet for an API Standard 650 storage tank containing information about the tank specifications, construction details, and appurtenances. Key details include: - The tank will have a nominal capacity of XX m3 located at a plant in XX. - It will be constructed of steel with XX number of shell courses and roof/bottom plates of varying thicknesses. - The tank will have features like a bolted door sheet, internal piping, and manholes/nozzles on the shell and roof. - Construction and welding details are provided along with coating and inspection requirements.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 3

DATE

API STANDARD 650


STORAGE TANK
DATA SHEET

March 5, 2015

BY
FILE NO.
PAGE

OF

APPURTENANCES (TO BE COMPLETED BY MANUFACTURER AND/OR PURCHASER


1. PURCHASER/AGENT
ADDRESS
CITY

PC/ZIP

PROV/STATE

PHONE

2. USER
3. ERECTION SITE:

NAME OF PLANT
LOCATION

4. TANK NO.

NOMINAL CAPACITY
IN

PUMPING RATES:

NET WORKING CAPACITY


OUT

m3 (bbl)
m /h (bbl/h)
3

6. MAXIMUM OPERATING TEMPERATURE

C (0F)

C (0F)

7. PRODUCT STORED:

DESIGN SPECIFIC GRAVITY

DESIGN METAL TEMPERATURE


8. CORROSION ALLOWAN...

m /h(bbl/h)
AT

C (0F)

kPa (in. water)

SHELL

mm(in.)

ROOF

mm (in.)

BOTTOM

mm(in.)

STRUCTURALS

mm (in.)

9. SHELL DESIGN:

BASIC STANDARD 650


DESIGN PRESSURE

10. ROOF DESIGN:

VAPOR PRESSURE

m3 (bbl)
3

APPENDIX A

APPENDIX F

kPa (lbf/in.2)

APPENDIX C (EXTERNAL FLOATING)


APPENDIX H (INTERNAL FLOATING)
NO
NOTE FOR SHOP TANKS

BASIC STANDARD 650


APPENDIX G (ALUMINUM DOME)
FRANGIBLE ROOF JOINT?
YES

11. ROOF DESIGN INFORMATI...


UNIFORM LIVE LOAD

kPa (lbf/in.2)

SPECIAL LOADS (PROVIDE) SKET...

kPa (lbf/in.2)

INSULATION LOAD

kPa (lbf/in.2)

MAXIMUM DESIGN ROOF TEMPERATURE

C (0F)

GASES IN THE VAPOR SPA...


12. EARTHQUAKE DESIGN?

13. WIND LOAD:

YES

ROOF TIE RODS (3,10,4,5)?

NO (APPENDIX B)

SEISMIC ZONE

IMPORTANCE FACTOR

ZONE FACTOR (TABLE E-2)

SITE COEFFICIENT (TABLE E-3)

VELOCITY

14. ENVIRONMENTAL EFFECTS: MAXIMUM RAINFALL

YES

MAXIMUM DIAMETER

EARTH

CONCRETE RINGWALL

NO

mm/h (in./h)

TOTAL SNOW ACCUMULATIO...


16. FOUNDATION TYPE:
REMARKS

NO

km/h (mph)

PROVIDE INTERMEDIATE WIND GIRDER (3.9....

15. SIZE RESTRICTIONS

YES

m (ft)

mm (in.)
MAXIMUM HEIGHT

OTHER

m (ft)

DATE

API STANDARD 650


STORAGE TANK
DATA SHEET

March 5, 2015

BY
FILE NO.
PAGE

OF

PAGE

OF

CONSTRUCTION DETAILS (TO BE COMPLETED BY MANUFACTURER AND/OR PURCHASER


1. MANUFACTURER
ADDRESS
CITY
SERIAL NO.

PROV/STATE

PC/ZIP

PROV/STATE

PC/ZIP

PHONE

2. FABRICATOR
ADDRESS
CITY

PHONE

SERIAL N...
3. MATERIAL SPECIFICATIONS SHELL
ROOF
BOTTOM
STRUCTURALS
4. NO. OF SHELL COURS...
5. PLATE WIDTHS AND THICKNESSES (INCLUDING CORROSION ALLOWANCE), IN mm...
1.

4.

2.

5.

8.

3.

6.

9.

6. TANK BOTTOM:

7.

PLATE THICKNESS

mm(in.)
SLOPE
mm/m (in/ft)
7. MINIMUM WIDTH AND THICKNESS OF BOTTOM ANNULAR PLATES (3.5) IN mm ...

LAP
TO

BUTT SEAMS
FROM CENTER

8. ROOF-TO-SHELL DETAIL (FIGURE F...


9. INTERMEDIATE WIND GIRDER?

YES

NO

TOP WIND GIRDER FOR USE AS WALKWAY?

SUPPORTED

10. ROOF TYPE:


SLOPE OR RADI...
11. ROOF PLATE:
12. PAINT:
SHELL--

SELF-SUPPORTED

YES
NO
FLOATING

mm (i...
THICKNESS
EXTERIOR?

mm (i...

YES

LAP

BUTT

NO

INTERIOR?

YES

NO

NO

INTERIOR?

YES

NO

YES

NO

INTERIOR?

YES

NO

YES

NO

MATERIAL

JOINT

SURFACE PREPARATION
BOTTOM--

UNDERSIDE?

YES

SURFACE PREPARATION
STRUCTURAL STEEL--

EXTERIOR?
SPECIFICATION

13. TANK BOTTOM COATING:

INTERIOR?

APPLICATION SPECIFICATION
14. INSPECTION BY:

SHOP

15. WELD EXAMINATION:

RADIOGRAPH

FIELD

SUPPLIEMENTARY LIQUID PENETRANT OR ULTRASONIC


16. FILMS
17. LEAK TESTING:

PROPERTY OF
BOTTOM

ROOF

SHELL
18. MILL TEST REPORTS:

REQUIRED?

YES

NO

PLATE

STRUCTURAL SHAPES

19. PURCHASER'S REFERENCE DRAWING


20. TANK SIZE:
21. DATE OF STANDARD 6...
REMARKS

DIAMETER

m (ft)

HEIGHT

m (ft)

DATE

API STANDARD 650


STORAGE TANK
DATA SHEET

March 5, 2015

BY
FILE NO.
PAGE

OF

PAGE

OF

APPURTENANCES (TO BE COMPLETED BY MANUFACTURER AND/OR PURCHASER


1. STAIRWAY STYLE:

CIRCULAR

2. WALKWAY:

LADDER
WIDTH

3. DRAWOFF SUMP:

STANDARD

4. BOLTED DOOR SHEET?

ANGLE TO HORIZONTAL

STRAIGHT
mm (i...

DEGREES

LENGTH

m (ft)

SPECIAL

YES

RAISED

NO (APPENDIS a TANKS ONLY)

FLUSH

5. SCAFFOLD HITCH
6. INTERNAL PIPING:

SWING LINE

SUCTION LINE

HEATING COIL SURFACE AREA


7. ROOF DRAIN:

m2 (ft2)

HOSE

JOINTED

SIPHON
8. NO. AND SIZE OF SHELL MANHOLES
9. NO. AND SIZE OF ROOF MANHOLES
10. SHELL NOZZLES (SEE FIGURES 3-4B, 3-5, AND 3-7 AND TABLES 3-8, 3-9, AND 3-...
FLANGED
MARK

SIZE

SGL

DBL

THREADED
SPL

ORIENTATION

HEIGHT FROM

N=0

BOTTOM

SERVICE

11. ROOF NOZZLES, INCLUDING VENTING CONNECTION (SEE FIGURES 3-14 AND 3-15 AND TABLES 3-16 AND 3-17
ORIENTATION DISTANCE FROM
MARK

SIZE

FLANGED

THREADED

REINFORCEMENT

N=0

NOTE: SKETCHES AND/OR SEPARATE SHEETS MAY BE ATTACHED TO COVER SPECIAL REQUIREMENTS.

CENTER

SERVICE