Steam Temp. Required Steam Temp. Initial Steam Pressure. Final Steam Pressure. Added Water Temp

This document contains calculations for the desuperheating water requirement at various locations in a plant with a capacity of 280 tons per hour. It lists the initial and final steam temperatures and pressures, heat input and output, and calculated water requirement for: 1) Attemperator at a 50 ton/hour boiler, requiring 1.4 tons/hour of water 2) Attemperator at a 75 ton/hour boiler, requiring 0.65 tons/hour of water 3) PRDS station processing 25 tons/hour of steam, requiring 4.7 tons/hour of water 4) IJT boiler exhaust of 20 tons/hour, requiring 3.3 tons/hour of water 5) Total plant water requirement
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
563 views3 pages

Steam Temp. Required Steam Temp. Initial Steam Pressure. Final Steam Pressure. Added Water Temp

This document contains calculations for the desuperheating water requirement at various locations in a plant with a capacity of 280 tons per hour. It lists the initial and final steam temperatures and pressures, heat input and output, and calculated water requirement for: 1) Attemperator at a 50 ton/hour boiler, requiring 1.4 tons/hour of water 2) Attemperator at a 75 ton/hour boiler, requiring 0.65 tons/hour of water 3) PRDS station processing 25 tons/hour of steam, requiring 4.7 tons/hour of water 4) IJT boiler exhaust of 20 tons/hour, requiring 3.3 tons/hour of water 5) Total plant water requirement
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 3

Steam temp.

Required steam temp.


Initial steam pressure.
Final steam pressure.
Added water temp.

Calculatiuon for desuperheating water requirement in plant


Sno.
Place
1 Attempterator
Walchand nagar boiler

Attempterator
Texmaco Boiler

At PRDS Station

IJT Boiler

5 Exhaust Steam
A) At PRDS Station

Calculation
Capacity of boiler 50 ton/ Hr.
Total heat at 440 Deg cel. = 793.5 * 50000 Kcal/Hr.
= 39675000 Kcal/Hr.
Total heat at 415 Deg cel. = 774.16 * 50000 Kcal/Hr.
= 38708000 Kcal/Hr.
Required quantity of water
Mw = (39675000 - 38708000) / (774.16 - 95)

Referance.
From (45Kg/cm2 , 440
Deg cel to (45 Kg/cm2,
415 Deg cel.
From steam table.
Water temp. 95 Deg cel.
Plant capacity 280 T/Hr.

Mw = 1.4 Ton / Hr

Steam consumption 50%


on cane.

Capacity of boiler 75 ton/ Hr.


Total heat at 440 Deg cel. = 779.6 * 75000 Kcal/Hr.
= 58470000 Kcal/Hr.
Total heat at 415 Deg cel. = 774.16 * 75000 Kcal/Hr.
= 58062000 Kcal/Hr.
Required quantity of water
Mw = (58470000 - 58062000) / (774.16 - 95)

From (45Kg/cm2 , 440


Deg cel to (45 Kg/cm2,
415 Deg cel.
From steam table.

Mw = 0.65 Ton / Hr

Steam consumption 50%


on cane.

Quantity of steam = 25 Ton / Hr


Total heat at 415 Deg cel. = 774.16 * 25000 Kcal/Hr.
= 19354000 Kcal/Hr.
Total heat at 180 Deg cel. = 667.0 * 25000 Kcal/Hr.
= 16675000 Kcal/Hr.
Required quantity of water
Mw = (19354000 - 16675000) / (667.0 - 95)

From (45Kg/cm2 , 415


Deg cel to (7.0 Kg/cm2,
180 Deg cel.
From steam table.

Mw = 4.7 Ton / Hr

Steam consumption 50%


on cane.

Quantity of steam = 20 Ton / Hr


Total heat at 370 Deg cel. = 761.3.16 * 20000 Kcal/Hr.
= 15226000 Kcal/Hr.
Total heat at 180 Deg cel. = 667.0 * 20000 Kcal/Hr.
= 13340000 Kcal/Hr.
Required quantity of water
Mw = (15226000 - 13340000) / (667.0 - 95)

From (21Kg/cm2 , 370


Deg cel to (7.0 Kg/cm2,
180 Deg cel.
From steam table.

Mw = 3.3 Ton / Hr

Steam consumption 50%


on cane.

Quantity of steam = 30 Ton / Hr


Total heat at 180 Deg cel. = 667.0 * 30000 Kcal/Hr.
= 20010000 Kcal/Hr.
Total heat at 126 Deg cel. = 648.4 * 30000 Kcal/Hr.
= 19452000 Kcal/Hr.
Required quantity of water
Mw = (20010000 - 19452000) / (648.4 - 95)

From (7.0Kg/cm2 , 180


Deg cel to (1.5 Kg/cm2,
126 Deg cel.
From steam table.

Mw = 1.0 Ton / Hr

Steam consumption 50%


on cane.

water temp. 95 Deg cel.


Plant capacity 280 T/Hr.

water temp. 95 Deg cel.


Plant capacity 280 T/Hr.

water temp. 95 Deg cel.


Plant capacity 280 T/Hr.

water temp. 95 Deg cel.


Plant capacity 280 T/Hr.

Sno.

Place

B) For shredder exhaust

C) Power Turbine exhaust

Calculation

Referance.

Quantity of steam = 18 Ton / Hr


Total heat at 150 Deg cel. = 660.5 * 18000 Kcal/Hr.
= 11889000 Kcal/Hr.
Total heat at 126 Deg cel. = 648.4 * 18000 Kcal/Hr.
= 11671200 Kcal/Hr.
Required quantity of water
Mw = (11889000 - 11671200) / (648.4 - 95)

From (1.5Kg/cm2 , 150


Deg cel to (1.5 Kg/cm2,
126 Deg cel.
From steam table.

Mw = 0.4 Ton / Hr

Steam consumption 50%


on cane.

Quantity of steam = 81 Ton / Hr


Total heat at 180 Deg cel. = 675.4 * 81000 Kcal/Hr.
= 54707400 Kcal/Hr.
Total heat at 126 Deg cel. = 648.4 * 81000 Kcal/Hr.
= 52520400 Kcal/Hr.
Required quantity of water
Mw = (54707400 - 52520400) / (648.4 - 95)

From (1.5Kg/cm2 , 180


Deg cel to (1.5 Kg/cm2,
126 Deg cel.
From steam table.

Mw = 4.0 Ton / Hr

Steam consumption 50%


on cane.

Total water requirement for desuperheating in plant at 280 TCH

water temp. 95 Deg cel.


Plant capacity 280 T/Hr.

water temp. 95 Deg cel.


Plant capacity 280 T/Hr.

15.5 Ton/Hr.