Basic Pipe Stress Analysis Tutorial
Basic Pipe Stress Analysis Tutorial
SST Basic Pipe Stress Analysis Tutorial, Version 1.00, 2011 - 2014, SST Systems, Inc. All
Rights Reserved.
Disclaimer
Please read the following carefully:
CAEPIPE and this tutorial have been developed and checked for correctness and accuracy
by SST Systems, Inc. However, no warranty, expressed or implied, is made by the authors or
by SST Systems, Inc., as to the accuracy and correctness of the tutorial or the functioning of
CAEPIPE and the accuracy, correctness and utilization of its calculations. Users must carry
out all necessary tests to verify CAEPIPE calculations, and the applicability of their results.
All information presented by CAEPIPE is for review, interpretation, approval and
application by a Registered Professional Engineer.
CAEPIPE is a trademark of SST Systems, Inc. All other product names mentioned in this
document are trademarks or registered trademarks of their respective companies/holders.
Good, relevant and non-overwhelming technical information on pipe stress analysis is hard
to come by. To partly remedy this problem, we provide a simple tutorial on the basics of
piping stress analysis. This tutorial is directed towards newcomers to Pipe Stress Analysis
just as much as to engineers new to CAEPIPE.
To get the full benefit from this tutorial, you will need a working copy of CAEPIPE, pipe
stress analysis software.
Download a Free Copy of CAEPIPE here
CAEPIPE - Features and Benefits
Useful learning resources:
CAEPIPE Tutorial 1
CAEPIPE Tutorial 2
CAEPIPE User's Manual
Pipe Stress Tips Archive
The Piping Journal Blog
You are welcome to use any other program if you choose to.
Tutorial: Table of Contents
Piping systems experience different types of loadings, categorized into three basic loading
types Sustained, Thermal and Occasional loads.
Sustained Loads
These mainly consist of internal pressure and dead-weight. Dead-weight is from the weight
of pipes, fittings, components such as valves, operating fluid or test fluid, insulation,
cladding, lining, etc.
Internal design or operating pressure causes uniform circumferential stresses in the pipe
wall, based on which a pipe wall thickness is determined during the process/P&ID stage of
plant design. Additionally, internal pressure gives rise to axial stresses in the pipe wall. Since
these axial pressure stresses vary only with pressure, pipe diameter and wall thickness (all
three of which are preset at the P&ID stage), these stresses cannot be altered by changing
the piping layout or the support scheme.
A pipes deadweight causes the pipe to bend (generally downward) between supports and
nozzles, producing axial stresses in the pipe wall (also called bending stresses) which vary
linearly across the pipe cross-section, being tensile at either the top or bottom surface and
compressive at the other surface. If the piping system is not supported in the vertical
direction (i.e., in the gravity direction) excepting equipment nozzles, bending of the pipe
SST Systems, Inc. | www.sstusa.com | Page 2
due to deadweight may develop excessive stresses in the pipe and impose large loads on
equipment nozzles, thereby increasing its susceptibility to failure by collapse.
Various international piping standards/codes impose stress limits, also called allowable
stresses for sustained loads, on these axial stresses generated by deadweight and pressure
in order to avoid failure by collapse.
For the calculated actual stresses to be below such allowable stresses for sustained loads, it
may be necessary to support the piping system vertically. Typical vertical supports to carry
deadweight are:
Rod hangers and resting steel supports fully restrain downward pipe movement but permit
pipe to lift up.
Two examples are presented in this tutorial to illustrate how piping can be supported by
spring hangers and resting steel supports to comply with the code requirements for
sustained loads.
Thermal Loads (Expansion Loads)
These refer to the cyclic thermal expansion or contraction of piping as it goes from one
thermal state to another (for example, from shut- down to normal operation and then
back to shut-down). If the piping system is not restrained in the thermal
growth/contraction directions (for example, in the axial direction of pipe), then, for such
cyclic thermal load, the pipe expands/contracts freely; in this case, no internal forces,
moments and resulting stresses and strains are generated in the piping system. If, on the
other hand, the pipe is restrained in the directions it wants to thermally deform (such as
at equipment nozzles and pipe supports), such constraint on free thermal deformation
generates cyclic thermal stresses and strains throughout the system as the system goes from
one thermal state to another. When such calculated thermal stress ranges exceed the
allowable thermal stress range specified by various international piping standards/codes,
then the system is susceptible to failure by fatigue. So, in order to avoid fatigue failure
due to cyclic thermal loads, the piping system should be made flexible (and not stiff).
This is normally accomplished as follows:
a) Introduce bends/elbows in the layout, as bends/ elbows ovalize when bent by end
moments, which increases piping flexibility.
b) Introduce as much offset as possible between equipment nozzles (which are
normally modeled as anchors in pipe stress analyses).
For example, if two equipment nozzles (which are to be connected by piping) are in line,
then the straight pipe connecting these nozzles will be very stiff. If, on the other hand,
the two equipment are located with an offset, then their nozzles will have to be
SST Systems, Inc. | www.sstusa.com | Page 3
Model the piping system in CAEPIPE (either directly inside CAEPIPE, or by using one of
SSTs data translators to import the piping model) and follow the steps shown in the
CAEPIPE Tutorial to learn the basics of operating CAEPIPE to create and analyze a
model and review its results. Once all the data is in, Analyze. Now, review Results.
General Procedure
From the thermal stress contour plot and the deflected shape for thermal load case,
suitably route the pipe to make it more flexible and position axial restraints and/or
intermediate anchors, if required, to direct thermal expansion/contraction away from
critical locations such as equipment nozzles. Similarly, decide the types and locations of
vertical supports based on the stress contour plot and deflected shape for sustained (=
weight + pressure) load case as well as the deflected shape for operating load case (=
sustained load + thermal load).
Here is a step-by-step procedure
Step 1
Review the thermal stress contour plot first. The plot is color-coded such that blue
region denotes areas with the least stress ratios (where stress ratio equals to actual
computed stress divided by material allowable stress), green region with higher stress
ratios, yellow region with even higher stress ratios, and red region with the highest
stress ratios. Intermediate areas between these distinct colors will be of bluish-green,
greenish-yellow and orange colors.
The goal will be to arrive at a layout that avoids orange and red zones in thermal stress
plot so that there is sufficient thermal margin left for performing a detailed piping analysis
when the layout is finalized at the 3D-design stage. You may wish to avoid even the
yellow zone in the stress contour plot so as to provide additional thermal margin for
future use. Since thermal stresses generated are directly dependent on how stiff or
flexible the layout is, in order to reduce thermal stresses, it may be necessary to make the
layout flexible (by including bends, offsets, loops etc.). So, the first step is to make sure
thermal stress ratios remain within blue to yellow range and not get into orange and
red zones. For more flexible layout, even yellow zone can be avoided.
Step 2
In case thermal stress ratios exceed yellow zone (and are in orange and red zones in
one or more areas of the piping system), it is important to study the thermal case deformed
shape provided by CAEPIPE in order to understand how the piping responds to pure
thermal load. By studying such deformed shape, it is possible to arrive at a layout with
appropriate bends, offsets and loops and/or with appropriately located axial
restraints/intermediate anchors such that thermal stress ratios do not exceed yellow
zone. This process may require you to perform several layout and/or restraint scheme
iterations.
Step 3
After finalizing piping layout under Steps 1 and 2 for thermal loading, the next task is to
support the system vertically to carry its deadweight under operating condition. In this
connection, first review sustained stress ratio contour plot generated by deadweight and
pressure for the system without any vertical supports excepting those provided by
equipment nozzles, shown in color codes from blue to green to yellow to red (as
in Step 2 above).
Your goal is to arrive at a vertical support scheme consisting of
(a) resting steel supports (b) rod hangers (c) variable spring hangers and (d) constant
support hangers
at appropriate locations (where such pipe supports can be attached to adjacent
concrete/steel structures, platforms etc.) so that stress contour plot for sustained stress
ratios avoids orange and red zones and remains within blue to yellow range.
Step 4
In case sustained stresses exceed yellow zone in one or more areas of the piping system,
study the deformed shape for sustained load case in order to understand how the piping
responds to its own deadweight: next, identify pipe locations in the 3D model where the
pipe can be vertically supported by the support types listed above. Based on this
information, it is possible to vertically support the piping such that sustained stresses do
not exceed yellow zone. This step may require you to execute several iterations within
CAEPIPE with several vertical support schemes.
In case, resting steel supports are selected to provide vertical support for piping under
sustained load, it is to be made sure that piping continues to rest on such steel supports
even during operating condition (= weight + pressure + thermal) and does not lift off from
these supports. If pipe lifts up at any of these resting supports during operating condition,
then that support does not carry any pipe weight and hence will not serve its purpose.
Similarly, at rod hanger locations, the tendency of piping should be to deform downward
for operating load case, so that the rod hangers carry the pipe weight under tension. On the
other hand, if pipe lifts up at any of the rod hangers, then that rod hanger goes into
compression thereby not carrying the weight of the piping during operating condition.
CAEPIPE displays the deflected shape of piping under operating load case too. By viewing
this deflection from different directions, you can make sure that piping is resting on steel
supports and/or piping is not deforming upward at rod hangers.
Step 5
You should perform Steps 1 to 4 for all piping systems of the project. Systems, for which
the layout and support schemes are finalized, are ready for detailed analyses and stress
report preparation.
Verification Step
Provide all additional input data into the models such as insulation thickness and density,
corrosion allowance and mill tolerance of pipe sections, thermal anchor movements,
SST Systems, Inc. | www.sstusa.com | Page 6
seismic anchor movements, support conditions such as friction and gap, other loads such
as wind, seismic and water/fluid hammer, multiple thermal and pressure cases, etc. and
perform detailed analyses. It is most likely that the layout and support schemes (finalized
during steps 14) meet all other pipe stress requirements (such as meeting nozzle allowable
loads) and hardly require any further iteration(s).
Example 1 - Using Expansion Loops
DATA: An 8 NB Schedule 80 pipe (see Fig. 1A) connects two equipment at nodes 10 and
30 with an offset of 4 (i.e., equal to distance between nodes 20 and 30). The pipe, made of
A53 Grade A carbon steel, is heated to 300 F.
This problem illustrates the use of expansion loops to reduce thermal stresses.
Figure 1A Layout
After modeling this layout in CAEPIPE, upon analysis, you will find that the pipe between
nodes 10 and 20 grows thermally to the right towards node 20, while pipe between nodes
30 and 20 grows up towards node 20, as illustrated in Fig. 1B.
This thermal deformation generates large thermal stresses (orange and red zones) in the
bend at node 20 and at anchor node 30, as shown in Fig. 1C.
Figure 1C - Non code-compliant (notice the reds)
The reds illustrate that the expansion stress is over the allowables, and fails code
compliance. This layout will have to be rerouted. Let us try the rerouting as shown in
Fig.1D.
Figure 1D - Rerouting
Fig. 1D shows a revised layout with a loop, introducing two additional bends at nodes 14
and 18, thereby making the layout more flexible. So, thermal growth of X-directional pipes
between nodes 10 and 14 and then between 18 and 20 as well as the growth of Zdirectional pipe between nodes 30 and 20 are absorbed by the three bends at nodes 14, 18
and 20. The corresponding stress contour plots for thermal and sustained load cases are
shown in Fig.1E and Fig. 1F, confirming code compliance.
Figure 2A Layout
Since the loop between nodes 10 and 40 is much more flexible (4 pipe) than the loop
between nodes 100 and 130 (8 pipe), the straight pipe between nodes 40 and 100 will
thermally grow mostly towards the 4 loop, as shown in Fig. 2B, straining the pipe between
nodes 10 and 40.
This, in turn, produces large thermal stresses (i.e., orange and red zones) in the 4 loop and
at anchor node 10, as observed in Fig. 2C. In other words, the thermal growth of pipe
between nodes 40 and 100 is mostly absorbed by the 4 loop and very little by the 8 loop,
defeating the very purpose of the 8 loop.
Figure 2E - Thermal Stress Contour Plot for Layout with Intermediate Anchor
Fig. 2F confirms that the present configuration with only two equipment nozzles at nodes
10 and 130 and an intermediate anchor at node 95 safely meets the code stress requirement
for sustained load.
SST Systems, Inc. | www.sstusa.com | Page 14
Figure 2F - Sustained Stress Contour Plot for Layout with Intermediate Anchor
This problem shows how axial restraints (i.e., pipe supports that prevent movement along a
pipes axis) can be effectively used to direct thermal growth towards expansion loops and
split thermal growth in a line such that the two piping portions grow in opposite directions.
Figure 3A - Layout with Intermediate Anchor at Node 95
Fig. 3A shows the same problem as in Example 2 but with a 6 NB branch line added at
the welding tee at node 70 (i.e., from node 70 to node 240).
The deformed geometry due to the thermal load (Fig. 3B), shows that the tee at node 70
does not move up in +Y-direction. The intermediate anchor at node 95 restrains the
vertical riser (between nodes 220 and 70) from thermally growing upward towards node 70.
As a result, this riser grows downward producing large bending moments and stresses at
and around equipment nozzle at node 240.
Since the intermediate anchor effectively restrains upward growth of this vertical riser node
70, we see large localized thermal stress at the welding tee. See thermal stress contour plot
shown in Fig. 3C.
Fig. 3D shows the same piping system with one axial restraint at 95 (replacing the
intermediate anchor at node 95) and another at node 210 the one at node 95 splits and
directs thermal growth towards the 4 and 8 loops and permits the horizontal line to
SST Systems, Inc. | www.sstusa.com | Page 18
move up in +Y-direction at node 70; the second one at node 210 splits the thermal growth
of the vertical riser (between nodes 220 and 70). The resulting deformed geometry plot in
Fig. 3E shows a more flexible system, which produces smaller forces and moments, and
hence stresses at the equipment nozzle node 240 and welding tee node 70.
Figure 3E - Thermal Deformation Plot for Layout with Axial Restraints
Figures 3F and 3G show the thermal and sustained stress contour plots (in this case
sustained stress is due to only deadweight as pressure is zero), confirming a code-compliant
system for both load cases.
Figure 3F - Thermal Stress Contour Plot for Layout with Axial Restraints
Figure 3G - Sustained Stress Contour Plot for layout With Axial Restraints
This example illustrates how to select and locate vertical supports to carry piping
deadweight in the operating condition.
Fig. 4A shows a practical problem with 10 NB Standard schedule pipe from equipment
nozzle at node 5 up to the reducer at node 30, 8 NB Standard schedule pipe from this
reducer to the pump nozzle at node 40, and a 6 NB Standard schedule branch line from
the welding tee at node 25 to the equipment nozzle at node 125.
Figure 4A - Layout with Node Numbers
The thermal stress contour plot given in Fig. 4B confirms that the piping system is highly
flexible and hence meets the code requirement for thermal load.
Fig. 4C shows the deflected shape for sustained load (i.e., mainly deadweight). It is
observed that the weight of
i.
ii.
iii.
iv.
The deformation response for deadweight, in turn, generates large forces and moments and
hence large sustained stresses at nozzle nodes 5 and 40 as shown in Fig. 4D for sustained
stress contour plot.
Fig. 4E shows the same layout with variable spring hangers at the bends at nodes 20 and
115, which carry piping deadweight and provide negligible restraint to thermal movement
from cold to hot condition and vice versa.
Figure 4E - Layout with Hangers
The thermal and sustained stress contour plots given in Fig. 4F and Fig. 4G confirm that
the piping system with hangers is code-complaint for both sustained and thermal load
cases.
Figure 4F - Thermal Stress Contour Plot for Layout with Hangers
This practical example illustrates how to place resting steel supports to carry the system
weight with operating fluid and modify the layout in order to re-direct thermal growth to
comply with code stress requirements.
Fig. 5A shows the initial layout where condensate from a tank (node 10) is extracted by the
pump suction lines. When one pump is operating, the other one is on standby.
Figure 5A - Layout with Node Numbers
From Fig. 5B, we see that the pipeline from nodes 10 to 100 grows thermally in the Z
direction (towards the pumps), whereas the two pump suction lines, one from nodes 120 to
180 and the other from nodes 110 to 250, grows in the opposite direction towards the tank
(+Z direction). So, the straight pipe between nodes 100 and 120 (with a welding tee at node
110) experiences two opposing deflection patterns - the pipe portion between nodes 110
and 120 is being deflected in the +Z direction like a rigid stick while the portion from
nodes 10 to 100 deflects in the -Z direction.
This causes the pipe between nodes 100 and 110 to bend at the tee producing high strains
and hence thermal stresses locally at the tee node 110, as shown in Fig. 5C.
Figure 5C - Thermal Stress Contour Plot
In order to reduce these thermal stresses at node 110, we cut the straight pipe between
nodes 100 and 120 into two parts one part is the pipe from nodes 100 to 110 and the
second part is from nodes 111 to 410 to 300. We then shift the second part downstream
towards the two pumps, resulting in the modified layout shown in Fig. 5D.
Figure 5D - Revised Layout with Node Numbers
This shift of pipe downstream does not adversely increase the pressure drop between the
tank at node 10 and the pumps at nodes 180 and 250. From the thermal deformation plot
for this revised layout shown in Fig. 5E, we can see that the two pump suction lines from
the suction nozzles to the welding tee at node 111 have almost equal thermal growth in the
+Z direction.
The branch pipe between nodes 111 and 300 acts as a rigid stick resulting in lower thermal
stresses in that branch pipe as seen in Fig. 5F.
Figure 5F - Thermal Stress Contour Plot for Revised Layout
In addition, we see that the two pump suction lines make the bend node 100 grow
thermally in the +Z direction, whereas the pipe from the tank node 10 to the bend node 90
grows in the Z direction. These opposing deflections rotate the interconnecting pipe
between nodes 90 and 100 like a (horizontal) see-saw in the horizontal XZ plane,
resulting in lower thermal stresses in this region, as observed in Fig. 5F.
Although the thermal stress criterion has been met, the weight stresses exceed the sustained
stress allowables, as illustrated by many red and orange areas in the sustained stress contour
plot given in Fig 5G.
Figure 5G - Sustained Stress Contour Plot for Revised Layout
This is because there are no vertical supports (excluding the three nozzles and a variable
spring hanger at node 52) to carry the weight of the system. Vertical resting supports are
therefore introduced as shown in Fig. 5H.
The recalculated sustained stress (i.e., weight + pressure) contour plot (with most areas in
blue) shown in Fig. 5I are now well below the allowable stress values, and hence codecompliant.
Figure 5I - Sustained Stress Contour Plot for Rested layout with Resting Supports
This concludes our tutorial on the basics of pipe stress analysis. We hope you feel
confident now in playing with CAEPIPE by creating simple models and conducting
several what-if studies on them, as alluded to in the examples above.
If you have questions, please feel free to send them to us ([email protected]). If you
have not downloaded the free pipe stress analysis software, visit www.caepipe.com or
www.sstusa.com.
If you found this document useful, please forward it to a colleague and Like our Pipe
Stress Analysis page on Facebook.