PNMT
PNMT
PNMT
NECITR-YTC
ART-SEP/03 V02
PNMT
FUNCTIONS
NECITR-YTC
ART-SEP/03 V02
PNMT
NECITR-YTC
ART-SEP/03 V02
COMMUNICATION BETWEEN THE PNMT AND THE RADIO NETWORK EQUIPMENT CAN BE :
VIA THE LA PORT OF THE LOCAL PASOLINK EQUIPMENT
VIA THE DIGITAL SERVICE CHANNEL DSC TO A REMOTE PASOLINK EQUIPMENT
LA PORT IS LOCATED ON THE FRONT OF THE EQUIPMENT AND
CONSISTS OF A DB15 CONNECTOR. LA PORT CONNECT THE
PM CARD IN THE IDU VIA A SERIAL CABLE TO THE RELEVANT
COMMUNICATION PORT OF THE PNMT COMPUTER.
PROPERTIES OF THE LA PORT ARE AS FOLLOWS:
PORT CONFIGURATION
RS-232
CONNECTOR TYPE
D-SUB 15 (FEMALE)
BITS PER SECOND RATEUP TO 19200
LA PORT
PNMT
HARDWARE/SOFTWARE CONFIGURATION
NECITR-YTC
ART-SEP/03 V02
START UP
NECITR-YTC
ART-SEP/03 V02
CONNECT THE PNMT PC COM1 PORT AND THE PASOLINK IDU LA PORT USING A RS232C CABLE
PREPARATION
PNMT
SHUT DOWN
NECITR-YTC
ART-SEP/03 V02
PNMT
NECITR-YTC
ART-SEP/03 V02
PNMT MAIN SCREEN IS SPLIT EVENLY TO DISPLAY THE DATA FROM THE TWO NEs IN THE HOP.
PNMT WINDOW
MENU BAR
COMMON TOOL BAR
LINK SUMMARY WINDOW
NE-SPECIFIC MENU ITEMS
BLOCK DIAGRAM
NE-SPECIFIC DATA
PNMT
NECITR-YTC
ART-SEP/03 V02
EQUIPMENT SETUP
MAINTENANCE
DETAILED MONITORING STATUS AND ALARMS OF EACH MAIN UNIT IN THE PASOLINK EQUIPMENT (ODU, IDU, AUX I/P
AND PMC) CAN BE VIEWED BY CLICKING ON THE RELEVANT TAB.
NE BLOCK DIAGRAM:
STATUS OF EACH MAIN UNIT IN THE PASOLINK EQUIPMENT (ODU, IDU, AUX I/P AND PMC) ARE SHOWN IN THE BLOCK
DIAGRAM AS SYMBOLS. WHEN ANY SYMBOL IS CLICKED THE RELATED EQUIPMENT WINDOW OPEN AND SHOWS THE
DETAILS OF ALARM AND STATUS DETAILS AND OTHER PARAMETERS,
PNMT
SYSTEM
REFRESH
NECITR-YTC
ART-SEP/03 V02
HELP
HELP
ABOUT
LOGIN / LOGOUT
CHANGE PASSWORD
ALARM BUZZER
CONNECT
THIS FUNCTION IS USED TO DISPLAY THE SUMMARY LIST OF THE NETWORK ELEMENTS IN
THE NETWORK
EXIT
THIS FUNCTION IS USED TO CLOSE THE PNMT PROGRAM
PNMT
EVENT LOG
NECITR-YTC
ART-SEP/03 V02
THIS FUNCTION UPLOAD THE EVENT LOG INFORMATION FROM THE SELECTED NE AND
DISPLAY THE INFORMATION IN EVENT LOG WINDOW
FREQUENCY SETTING
TX POWER CONT
BIT RATE
EQUIPMENT SETUP
SYSTEM CONFIG
MAINTENANCE
LAN SETTING
FRAME ID
BER THRESHOLD
AIS SEND ON/OFF
TX MUTE ON/OFF
CW ON/OFF
NE NAME
NOTE
SWITCHOVER (1+1)
PNMT
10
NECITR-YTC
ART-SEP/03 V02
CLICK ON SYSTEM IN THE MENU BAR AND THEN CLICK ON LOGIN/LOGOUT IN THE DROP DOWN MENU TO OPEN
THE LOGIN/LOGOUT WINDOW
PNMT
11
Item
Monitor(0)
User(1)
Local(2)
Remote(3)
Admin(4)
DATE TIME
ALARM BUZZER
NECITR-YTC
ART-SEP/03 V02
UPDATE
IDU
MAINTENANCE
CH (LB1) / CH(LB2)
CH (ALARM INHIBIT)
MAINTENANCE MODE
TX MUTE
CW
TX ATTENUATION
BER AIS
EQUIPMENT CONFIGURATION
BIT RATE
BER THRESHOLD
FRAME ID
NOTE
OPTO NAME
RELAY NAME
RELAY CONTROL
PMON THRESHOLD
SAVE TO DISK
LOGGING
SAVE TO DISK
PMC
RESET
PASOLINK NAME
AUX I/O
PMON
PNMT
12
OVERALL WINDOW
NECITR-YTC
ART-SEP/03 V02
TX ATTENUATION USED
TX AND RX FREQUENCIES USED
BIT RATE USED
MAINTENANCE MODE ON OR OFF STATUS. IF ON, BACK GROUND COLOR
CHANGE TO YELLOW.
SELECTED TX AND RX CHANNEL IN (1+1) HOT STANDBY CONFIGURATION
FRAME ID USED
ODU TYPE USED V3 OR V4
CLICK THE OVERALL TAB TO DISPLAY THE OVERALL
WINDOW
PNMT
13
ODU WINDOW
NECITR-YTC
ART-SEP/03 V02
CLICK THE ODU SYMBOL IN THE BLOCK DIAGRAM TO OPEN THE ODU
WINDOW TO VIEW THE ODU DETAILS
ODU WINDOW FOR (1+1) CONFIGURATION
CLICK THE ODU TAB TO OPEN THE ODU WINDOW TO VIEW THE ODU DETAILS
PNMT
14
ODU DETAIL
NECITR-YTC
ART-SEP/03 V02
STATUS COLORS
GREEN
NORMAL
RED
ALARM
PNMT
15
IDU WINDOW
NECITR-YTC
ART-SEP/03 V02
CLICK THE IDU SYMBOL IN THE BLOCK DIAGRAM TO OPEN THE IDU WINDOW TO VIEW THE IDU DETAILS
CLICK THE IDU TAB TO OPEN THE IDU WINDOW TO VIEW THE IDU DETAILS
PNMT
16
IDU DETAIL
NECITR-YTC
ART-SEP/03 V02
STATUS COLORS
GREEN
NORMAL
RED
ALARM
PINK
MINOR ALARM
PNMT
17
IDU DETAIL
NECITR-YTC
ART-SEP/03 V02
NORMAL/ALARM/INHIBIT
NORMAL/ALARM
NORMAL/SEND
NORMAL/RECEIVED
ON/OFF
ON/OFF
ON/OFF
BP OUTPUT
AIS SEND
AIS RECEIVED
LB-1
LB-2
ALARM INHIBIT
ALARM INHIBIT
OFF
PNMT
18
CHANNEL CONTROL
NECITR-YTC
ART-SEP/03 V02
PNMT
19
CHANGE PASSWORD
NECITR-YTC
ART-SEP/03 V02
PNMT
20
ALARM BUZZER
CLICK ON ALARM BUZZER ON
THE SYSTEM DROP DOWN
MENU TO OPEN THE ALARM
BUZZER SETTING WINDOW.
NECITR-YTC
ART-SEP/03 V02
PNMT
21
NECITR-YTC
ART-SEP/03 V02
CLICK CONNECT ON THE SYSTEM DROP DOWN MENU TO LIST THE LOCAL NEs THE PNMT IS CONNECTED TO.
LIST MENU
PNMT
22
HELP FUNCTION
NECITR-YTC
ART-SEP/03 V02
PNMT
23
NECITR-YTC
ART-SEP/03 V02
SHOW THE WS
CHANNEL
INFORMATION
SHOW THE
SERVICE CHANNEL
INFORMATION
PNMT
24
NECITR-YTC
ART-SEP/03 V02
ODU SECTION OF THE EQUIPMENT SETUP WINDOW FOR THE SELECTED PASOLINK HAS THREE
CONTROLS, FREQUENCY PLAN , TX ATTENUATION AND TX POWER CONTROL SETTING.
IN THE CASE OF (1+1) HOT STANDBY CONFIGURATION, FREQUENCY IS SET FOR BOTH ODUs.
CLICK ON THE FREQUENCY PLAN BUTTON TO SELECT
THE ODU TX AND RX FREQUENCIES.
INFORMATION ABOUT THE ODU FREQUENCY BAND ARE
DISPLAYED
PNMT
25
ATPC SETTING
NECITR-YTC
ART-SEP/03 V02
TX POWER CONTROL
WHEN TC CONTROL MODE IS ATPC, TX
ATTENUATION SETTING VALUE IS IGNORED
RX THRESHOLD LEVEL
WHEN THE MONITORED RX SIGNAL LEVEL
FALLS BELOW THIS LEVEL, CONTROL SIGNAL
SENT TO THE OPPOSITE STATION INITIATE THE
ATPC FUNCTION.
THIS IS EFFECTIVE ONLY WHEN THE OPPOSITE
STATION IS SET TO ATPC MODE
CLICK THE APPROPRIATE BUTTON TO
OPEN THE SELECTED SETTING WINDOW..
PNMT
26
IDU SETTING
BIT RATE SETTING
NECITR-YTC
ART-SEP/03 V02
IDU SECTION OF THE EQUIPMENT SETUP WINDOW FOR
THE SELECTED PASOLINK HAS CONTROL SETTINGS FOR
THE MAIN SIGNAL.
REDUNDANCY
CLICK REDUNDANCY BUTTON TO OPEN THE REDUNDANCY
CONFIGURATION SETTING WINDOW. SELECT THE REQUIRED
CONFIGURATION. CLICK ON THE EXECUTE BUTTON TO SET THE
REDUNDANCY CONFIGURATION.
FRAME ID
CLICK FRAME ID BUTTON TO OPEN THE
FRAME ID SETTING WINDOW.
SELECT THE FRAME ID AND CLICK ON
THE EXECUTE BUTTON TO SET IT.
MAKE SURE THAT BOTH NEs IN THE
HOP HAVE THE SAME FRAME ID VALUE.
PNMT
27
NECITR-YTC
ART-SEP/03 V02
IN THE PASOLINK SYSTEM WHEN AIS IS DETECTED FROM THE INPUT 2MB STREAM AIS RCVD CONDITION IS DECLARED. THIS CONDITION
CAN BE DEFINED AS AN ALARM CONDITION OR STATUS CHANGE EVENT. SIMILARLY AIS IS SENT TO THE 2MB STREAM IN THE RECEIVE
DIRECTION UNDER CERTAIN CONDITIONS. AIS SEND CAN ALSO BE DEFINED AS AN ALARM CONDITION OR STATUS CHANGE EVENT.
PNMT
28
NECITR-YTC
ART-SEP/03 V02
SC1
EOW
Analog
SC2
SC3
DSC3
DSC4
Analog
Digital
ASC INTFC or
DSC INTFC
Option
Option
SC4
DSC1
Digital
9.6Kbps RS 232C or
64Kbps with G703/V11 card
Option
SC5
DSC2
Digital
SC6
NMS
SC4
SC4
64K V.11
64K G703
9.6K RS-232
PNMT
29
NECITR-YTC
ART-SEP/03 V02
PNMT
30
MAINTENANCE
CLICK MAINTENANCE, ON THE,
CONFIGURATION DROP DOWN
MENU TO OPEN THE
MAINTENANCE WINDOW
NECITR-YTC
ART-SEP/03 V02
PNMT
31
NECITR-YTC
ART-SEP/03 V02
AUXILIARY INPUT / OUTPUT FACILITY CAN BE USED TO MONITOR SIX EXTERNAL MONITOR ITEMS AND FOUR EXTERNAL CONTROL ITEMS USING THE
PASOLINK MANAGEMENT SYSTEM. MONITORING ITEMS ARE CONNECTED THROUGH OPTICAL COUPLERS AND CONTROLS VIA RELAYS. THESE ITEMS
ARE ALSO KNOWN AS HOUSEKEEPING ALARMS AND CONTROLS.
CLICK THE AUX SYMBOL IN THE BLOCK DIAGRAM OR AUX I/O TAB TO
VIEW THE AUX ALARM/STATUS/CONTROL DISPLAY
PNMT
32
NECITR-YTC
ART-SEP/03 V02
PNMT
33
NECITR-YTC
ART-SEP/03 V02
DATE AND TIME STORED IN THE SELECTED NETWORK ELEMENTS PM CARD CAN BE DISPLAYED AND ADJUSTED FORM THIS CONTROL ITEM
[PMC WINDOW]
TO DISPLAY THE CURRENT DATE/TIME
STORED IN THE PM CARD, SELECT
GET DATE/TIME AND CLICK EXECUTE.
CLICK DATE/TIME
BUTTON IN THE PMC
WINDOW TO OPEN THE
DATE/TIME SETTING
CONTROL WINDOW
PNMT
34
NECITR-YTC
ART-SEP/03 V02
DOWN LOAD
SELECT EACH CONFIG FILE ONE BY ONE FROM
THE TYPE WINDOW
BROWSE AND SELECT THE PATH/LOCATION TO
THE FILE SELECTED IN THE TYPE WINDOW.
CLICK EXECUTE BUTTON TO DOWN LOAD THE
SELECTED CONFIG FILE..
REPEAT THE DOWNLOAD PROCEDURE FOR THE
OTHER CONFIG FILE..
UPDATE
AFTER THE SUCCESSFUL DOWN LOAD OF
THE CONFIGURATION FILES. CLICK
UPDATE BUTTON. UPDATE
CONFIGURATION FILE WINDOW OPENS.
SELECT THE APPROPRIATE BOX FOR THE
TYPE OF CONFIGURATION FILE(S) THAT
WILL BE UPDATED.
CLICK OK BUTTON TO START THE UPDATE
OPERATION..
WHEN UPDATING SYSTEM.CFG FILE , PMC TO
PMC COMMUNICATION WILL BE LOST WHEN PM
CARD INITIALIZES TO THE NEW SYSTEM
CONFIGURATION. DURING THIS TIME PNMT
CONNECTION TO THE PASOLINK WILL BE LOST
BUT WILL AUTOMATICALLY BE RECONNECTED
AFTER THE PMC RESETS
Network Config
ME Config
PPP Config
With ROM (PMC Program ) Switching
Execute
PNMT
35
NECITR-YTC
ART-SEP/03 V02
CLICK ON THE PROGRAM FILE BUTTON UNDER THE DOWNLOAD (PC>>PMC) IN THE
PMC WINDOW.
[PMC WINDOW]
A:\pm.pof
PM CARD CAN BE RESET
USING THIS FUNCTION
CLICK THE PMC RESET
BUTTON ON THE PMC
WINDOW.
WARNING
MAKE SURE THAT THE CORRECT
PROGRAM FILE IS DOWNLOADED
TO THE PM CARD. INCORRECT
PROGRAM FILE WILL LEAD TO PM
CARD FAILURE.
PNMT
36
NECITR-YTC
ART-SEP/03 V02
[PMC WINDOW]
ENTER THE LOCATION THE FILE TO BE UPLOADED AND THE FILE NAME IN
THE FILE WINDOW. USE BROWSE TO LOCATE THE DIRECTORY IF
NECESSARY.
CLICK EXECUTE BUTTON TO START THE UPLOAD OPERATION. A MESSAGE
WINDOW APPEARS TO SHOW THE STATUS OF THE UPLOAD OPERATION,
AND WILL CLOSE AUTOMATICALLY ONCE THE OPERATION IS COMPLETED..
AFTER THE UP LOAD IS FINISHED CLICK THE CLOSE BUTTON TO CLOSE
THE WINDOW.
PNMT
37
EVENT LOG
NECITR-YTC
ART-SEP/03 V02
PNMT
38
NECITR-YTC
ART-SEP/03 V02
ES
SES
UAS
BBE
ERROR SECONDS
SEVERELY ERROR SECONDS
UNAVAILABLE SECONDS
BACKGROUND BLOCK ERRORS
PNMT
39
NECITR-YTC
ART-SEP/03 V02
PNMT
40
NECITR-YTC
ART-SEP/03 V02
PASOLINK V4 SOFTWARE
41