0% found this document useful (0 votes)
2K views52 pages

Basic PULSE Labshop Tutorial

This document provides an introduction to modal analysis and working with the Pulse Labshop software. It discusses modal analysis techniques for better understanding dynamic behavior and optimizing dynamic properties of structures. The document outlines equipment in the modal analysis lab and how to connect sensors to the data acquisition system and Pulse Labshop software. It describes extracting time and frequency response data, frequency response functions, using the Modal Test Consultant feature, and exporting data to other software programs.

Uploaded by

Sufyan Azam
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
2K views52 pages

Basic PULSE Labshop Tutorial

This document provides an introduction to modal analysis and working with the Pulse Labshop software. It discusses modal analysis techniques for better understanding dynamic behavior and optimizing dynamic properties of structures. The document outlines equipment in the modal analysis lab and how to connect sensors to the data acquisition system and Pulse Labshop software. It describes extracting time and frequency response data, frequency response functions, using the Modal Test Consultant feature, and exporting data to other software programs.

Uploaded by

Sufyan Azam
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 52

PULSE Labshop

1392

Pulse Labshop





Modal Test Consultant

2
3
5
7
31
47
47

Pulse Labshop



.
.

. -


.
.
1
2 . 3
.

.
PULSE Brel & Kjr
.
PULSE Labshop .
.

Classical Modal Analysis


Operational Modal Analysis
)l3 Frequency Response Functions (FRFs
1
2

Pulse Labshop


1 2
.
. PULSE Labshop
.

Hammer
Shaker

1
2

Pulse Labshop

MEScope
MATLAB.
.

IDAe Frame Type 3560C B&K

Modal Exciter 4824 B&K

Impact Hammer AU02 Global Test

Piezoelectric Accelerometer
Monoaxial and Triaxial DjB

Miniature Piezoelectric
Accelerometer 4516 B&K

ICATS Pulse Labshop MEScope


.

Pulse Labshop


1 2 .

.
PULSE - Front-end Setup
.

.1

PULSE - Front-end Setup .


Start>PULSE>PULSE Front-end Setup

.2

.
Connect .

.3

Next .
Pulse Front-end
Ethernet

1
2

Pulse Labshop

.4

.
Finish Exit .

Pulse Labshop


.
Control Panel Network Connection .
IP Address: 10.10.10.50
Subnet Mask: 255.255.0.0
Preferred DNS: 172.36.0.250


PULSE Labshop
.
.

.
.
.

Pulse Labshop

:

PULSE Labshop





.
.
.
.
.1 PULSE Labshop .

Pulse Labshop

.2 Create blank project .



.
.

.3 .
Organiser .

Pulse Labshop

Configuration

.
.
Measurement

.
Function

.
Display

.
.4
.
ConfigurationMeasurementFunctionDisplay

.5
.

10

Pulse Labshop

.6 + Configuration

. 3560C
.

LAN Interface Module Type 7533


.

11

Pulse Labshop

6/1 ch. Input/Output Module Type 3032


. 6 .
.7
. Select

Transducer .

.8 Database Administrator
.
4516 .

12

Pulse Labshop

.9 OK -
. .
Add Signal
. Edit Label
Accelerometer .

.10 Activate

Template .

13

Pulse Labshop

.11 Configuration Measurement

Organiser .

.12
. Groups
New Group .
Edit Label .

.13 Accelerometer Group .


. .

.

14

Pulse Labshop

.14 .
FFT .
Setup Insert FFT Analyzer -
.

.15 FFT .
FFT Analyzer Insert Group
Accelerometer Group .

15

Pulse Labshop

.16 Activate Template


.
.

.17 FFT Analyzer Input


.

16

Pulse Labshop

.18 FFT Analyzer Setup


Properties .

.19 .
1 .
.

. ) (Trigger 1
New
. Signal .

Trigger

17

Pulse Labshop

.20 Graphical Setup .

18

Pulse Labshop

.
Start
.

19

Pulse Labshop

.
1 .

.
.

.
Trigger level

20

Pulse Labshop

OK .

.21
. .
1 .
500
.

Delay

21

Pulse Labshop

.22 FFT Analyzer .


Measurement Organiser FFT Analyzer
Properties .
1600 1.6kHz
. 1600
. .

22

Pulse Labshop

Trigger
Start Trigger Record Trigger .
Activate Template .

.23 Measurement Organiser

Function

Organiser .

23

Pulse Labshop

Function Group Insert


.

Autospectrum .
Properties .

Time .
Function Autospectrum Time
.

24

Pulse Labshop

Function Group

Insert
Autospectrum .


Show as>Classic display .

25

Pulse Labshop

.24

26

Pulse Labshop

View>Task Bar Task List


Add Task .

Configuration
.
Change Icon

27

Pulse Labshop

Task>Save Task Layout


. Configuration
.

Display

Time

Autospecturm . Task Bar


Add Task .

Window Time Autospecturm


Display Save

Task Layout .
28

Pulse Labshop

Display Configuration
. Display Measurement

Bar Active Template .

29

Pulse Labshop


Save Task Layout .

.25 Start Measurement Bar-


.

.
.
.26 Time
Autospectrum .
Properties Y Axis
Autoscale .

30

Pulse Labshop

File> Save
.



.
. AU02
.
.1 1 9 -
AU02
Hammer .
.

31

Pulse Labshop

.2 Activate Template .
.3 12 13
Hammer Accelerometer .
.4 14 15 FFT Analyzer Setup
Hammer Accelerometer FFT .
.5 Activate Template
Measurement Organiser .

32

Pulse Labshop

.6 Measurement Organiser
Properties . Channel Gain

-1 . Hammer .

.7 Setup Properties
. Trigger New
. Hammer Signal.

33

Pulse Labshop

.8 Hammer .

34

Pulse Labshop

.9 Graphical Setup Start


.


. )
( 10 20 5 .

. 21 -0.5s
.

35

Pulse Labshop

.10 FFT Analyzer .


Measurement Organiser FFT Analyzer
Properties .
1600 1.6kHz
. 1600
.

.11
.
Averaging 3 Linear
.
.12 Trigger Hammer trigger -
.

36

Pulse Labshop

.13 Spectra Hammer Group Cross-spectrum


.
.

.14

Measurement Organiser Setup

FFT

Analyzer Hammer Group Properties -


. 1
.

Transient

37

Pulse Labshop

.15

Accelerometer Group 1

Exponential

38

Pulse Labshop

.16

Activate Template . Function

Organiser .
.17

Function Organiser Function Group

Insert . ) Autospectrum (Hammer


Properties

. Frequency Response H1
Accelerometer Hammer
.

.18

Coherence .

.19

Classic Display Show As

39

Pulse Labshop

.20

Function Organiser .

24 Task Bar New Task


Time Weighting
Task>Save Task Layout .
)Time(Accelerometer
)Time(Hammer
)Time Weighting (Accelerometer
)Time Weighting (Hammer

40

Pulse Labshop

.21

Activate Template .

.22

Run

. Stop .

Properties YAxis Autoscale .

41

Pulse Labshop

42

Pulse Labshop

.23

Properties

Function
.

43

Pulse Labshop

.
.

.24 Averaging -
.
.

.25 ) (FRF Coherence


. FRF

44

Pulse Labshop

)
( .
.

.26 Coherence )
( .
.
) ( 3 .
1
Coherence . 2
3
Coherence .

Resonance
Antiresonance
3 Noise
1
2

45

Pulse Labshop

.27 275
Measurement Organiser FFT
Analyzer Properties Analysis .

mode Zoom Cenre Frequency 275Hz .


800 200Hz .
.

.28

Coherence

215 Hz .

46

Pulse Labshop

Modal Test Consultant


PULSE Labshop

. Modal Test Consultant (MTC)


.
MTC .
.
.

.
Start>PULSE>Applications>Modal Analysis>MTC Hammer
Start>PULSE>Applications> Modal Analysis>MTC Shaker



.
.
Save

Active Curve .

47

Pulse Labshop

txt
X
Y .
Function Organiser Display

Organiser Copy.

48

Pulse Labshop

Microsoft Excel

. Paste -
Copy Excel
Paste Special Excel


Excel .

49

Pulse Labshop

MATLAB Bridge to MATLAB .


Component
Bridge to MATLAB .

MATLAB
m Export .

50

Pulse Labshop

MATLAB
MATLAB Command window
Structure MATLAB
.

MEScope Bridge to MEScope


. Component Modal Test Consultant

Start>PULSE>Applications>Modal Analysis> Bridge to MEScope


.

51

You might also like