Optimizing Vacuum Systems
Optimizing Vacuum Systems
Evaluating operating costs can make or break the profit of a commodity, and can dictate whether an expansion should take place.
Ejectors can be designed as single-element or multielement systems, allowing for flexibility in the process load condition. Along
with the steam jet ejectors, shell-and-tube vacuum condensers can
be utilized in the system design to condense steam and organic
vapors and cool the non-condensible gases to the optimum interstage pressures.
EJECTOR OPERATION
Steam jet ejectors have long been used as a means of transporting
gases, liquids or solids from one pressure level to a higher pressure
level, particularly in subatmospheric applications.
The ejector has no moving parts, making it easy to operate and
durable.
In operation, atmospheric- to high-pressure fluid passes through a
motive nozzle where its pressure is dissipated, accelerating the
fluid to high velocity as it exits the mouth of the nozzle.
This high-velocity fluid stream (usually steam) issuing from the
nozzle mouth entrains the suction fluid. These two streams mix as
they pass into a diffuser. The velocity profile constantly changes
and the pressure inside the venturi of the ejector continues to rise
as the discharge of the venturi is reached.
STEAM CONSUMPTION
While the use of steam jet ejectors is an economical method of
transporting product between pressure levels, to obtain optimum
energy efficiency a design that reduces steam consumption should
be considered.
Energy costs for the operation of an ejector-condenser unit vary
widely. With steam, the cost depends on the generation method
(i.e., oil, gas, coal and electricity). For example, steam costs vary
from $1.00 to $15.00 per 1,000 lb; while the cost of cooling
water varies from $0.30 to $2.50 per 1,000 gal; and electricity
costs vary from $0.02 to $0.10 per kw per hr.
PUMP OPERATION
A mechanical liquid-ring pump can operate singly, or can be paralleled with any combination of ejectors. The pump uses a seal liquid
(usually water), which is thrown to the periphery of the casing to
form a liquid ring (Fig. 2).
The liquid ring seals the space between the impeller blades and the
casing, and the chambers at the top-most part of the impeller hub
are filled with liquid.
As the pumps impeller rotates, the liquid ring moves away from
the hub. This movement increases the space in the pumping chamber and draws gas into the chambers. As the impeller rotates, any
gas in the impeller chambers is compressed by the liquid ring and
expelled through the discharge port. This sequence is repeated with
each revolution. The seal liquid absorbs the heat created by compression, friction and condensation.
The pump is driven by an electric motor at standard speeds from
400 rpm to 1,750 rpm and in some cases, at speeds to 3,600 rpm.
Routine inspection, maintenance and repairs usually are accomplished during scheduled turnarounds, reducing equipment
downtime.
For water conservation, a complete recirculation-type system or
partial recirculation system can be purchased.
Based on the pumping capacity shown in Fig. 3, a single-stage pump
has a higher capacity than a two-stage pump at pressures of approximately 225 mm Hg absolute and higher; whereas a two-stage pump
has a higher capacity at pressures less than 225 mm Hg. The singlestage ejector consumes 432 lb per hr of 100-psig steam.
To accomplish the same performance, a single-stage or two-stage
liquid-ring pump would require a motor utilizing 13 brake horsepower (BHP). (Refer to the figure in the sidebar for estimating the
costs of steam and electricity in specific cases.)
SYSTEM BENEFITS
In addition to energy optimization, the use of a system utilizing a
combination of liquid-ring pumps and steam jet ejectors (Fig. 4)
reduces noise and maintenance hazards.
Sound pressure levels measured on the dBa scale at 1 m are considerably lower for a single- or two-stage liquid-ring pump compared
to a single-stage ejector discharging to a shell-and-tube aftercondenser. An ejector often has to be insulated with a noise and
thermal barrier material, which is cumbersome during system
maintenance.
COST CONSIDERATIONS
IN VACUUM SYSTEM DESIGN
To assess the utility costs of combination liquid-ring pump
and ejector systems, a three-stage ejector system is designed
in which the third-stage ejector consumes 1,830 lb per hr of
100-psig steam. The three-stage system typically would be
arranged with a first-stage ejector discharging into a vacuum
condenser, a second-stage ejector discharging into a second
vacuum condenser, and a third-stage ejector discharging into
an aftercondenser.
For this example, the third-stage ejector is replaced with a liquidring vacuum pump, creating a system with a two-stage ejector,
one vacuum intercondenser and a liquid-ring vacuum pump.
The single-stage liquid-ring pump absorbs 50 brake horsepower (BHP) and has the same performance capabilities as
the third-stage ejector.
Arbitrarily selecting a steam cost of $5.00 per 1,000 lb and
an electrical cost of $0.10 per kw per hr results in a steam
cost of $80,000.
To operate the liquid-ring pump, the electrical cost is
$32,000, providing a utility savings of $48,000.
In addition to energy savings, capital cost for associated equipment also must be considered to find the actual payback period.
The third-stage ejector utilizes a shell-and-tube aftercondenser,
which is not required in the liquid-ring pump design.
The capital cost of the ejector and shell-and-tube aftercondenser is approximately $12,000; while the liquid-ring pump
and its associated equipment is approximately $14,000.
Thus, the use of the liquid-ring pump provides a total cost savings of $46,000 in the first year, without considering savings
that can be gained from the use of a smaller platform, and the
elimination of energy required to extract Btus from the cooling
tower water used in the shell-and-tube aftercondenser.
This example looks at replacement of only the third-stage ejector. Other design considerations include replacement of the
intercondenser and aftercondenser for potential energy savings.
A comparison of approximate costs of steam and
electricity. Using these
rates, an individual can
analyze the cost savings
based on the rates that
are applicable for his/her
locality.
The horizontal axis is
labeled in pounds of
steam (consumed or
saved) and the approximate equivalent pump
BHP, and the vertical
axis is the steam or electrical cost per year.
2
DESIGN CONSIDERATIONS
While energy conservation is a key factor in the design of a vacuum
system, there are several other specifics that should be taken into
consideration. Among these are:
Approach temperature;
Percent non-condensibles;
Existing system revamp, including properly matching up existing ejectors with new pumps.