0% found this document useful (0 votes)
250 views4 pages

MULTI REPEATER Inter-Connections

1) The document provides instructions for programming option registers and identification registers on a MULTI-REPEATER system. It explains how to enter codes into the registers using a programmer by pressing keys and entering sequences of 0s and 1s. 2) Default factory settings are provided for the registers. The document also lists different protocols and formats that can be used for the repeater system such as 10+4, 10+4+4, DTMF, and explains how the multi-repeater can be used to support different radio brands and functions. 3) Diagrams and explanations show how the multi-repeater can be configured to operate in different modes to support applications such as connecting to a base station,
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
250 views4 pages

MULTI REPEATER Inter-Connections

1) The document provides instructions for programming option registers and identification registers on a MULTI-REPEATER system. It explains how to enter codes into the registers using a programmer by pressing keys and entering sequences of 0s and 1s. 2) Default factory settings are provided for the registers. The document also lists different protocols and formats that can be used for the repeater system such as 10+4, 10+4+4, DTMF, and explains how the multi-repeater can be used to support different radio brands and functions. 3) Diagrams and explanations show how the multi-repeater can be configured to operate in different modes to support applications such as connecting to a base station,
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

MAMI

MANUFACTURING AND MINOR INVENTIONS

MULTI - REPEATER
P1

M000048

PROGRAMMING THE OPTION REGISTERS 1

& 2

TO PROGRAM REMOVE LINK P AS INDICATED ON WIRING DIAGRAM:


1- HOLD THE SELECTED REGISTER KEY
2
UNTIL A "P" IS DISPLAYED ( E.G. "2")

TO VIEW:
BRIEFLY PRESS THE NUMBER OF THE
REGISTER YOU WISH TO CHECK.

2 - ENTER A SEQUENCE OF "0" AND "1"


AS REQUIRED

THE REGISTER CONTENTS WILL BE DISPLAYED


SEQUENTIALLY.

OR

( N O T E : D ATA

IS

ENTER

0
0
0
0
0
0
0
0

REPEATER
UHF TO UHF

OR

YOUR

FROM

SELECTIONS

TOP

TO

D E FA U LT

BOTTOM.)
SETTINGS

HERE

RADIO TRANSMITTER

OR
1= AM INPUT REPEATED IN DTMF
1= AM INPUT REPEATED IN MAMI 10+4+4
1 = FM INPUT REPEATED IN DTMF
1 = FM INPUT REPEATED IN MAMI 10+4+4
1 = RELAY DRIVER
1 = QD PROTOCOL
1 = AUTOMATIC CHECK IN

=AM INPUT REPEATED IN MAMIFORMAT


=AMINPUT REPEATED IN MAMI10+4
=FM INPUT REPEATED IN MAMIFORMAT
=FM INPUT REPEATED IN MAMI10+4
= NO RELAY DRIVER
= MAMI PROTOCOL
= NO CHECK IN

SPARE (NOT USED)

RADIO RECEIVER
SQUELCH

NOTE:
USE ONLY
6 PINS

RADIO RECEIVER

LINK COMBO FOR


MULTI REPEATER

SQUELCH

10 + 4
10 + 4 + 4

VERSION
OF PROGRAM

REGISTER

TRANSAVER
UHF TO VHF

RADIO TRANSMITTER

ENTERED

FA C T O R Y- P R O G R A M M E D

REGISTER
BIT
N O.

MULTI REPEATER
inter-connections

RESET

PROGRAM PINS

SYSTEM MEMORY

( N O T E : D ATA I S E N T E R E D F R O M T O P T O B O T T O M . )

0
1
0
1

1
1
0
1

0
0
1
1

1
0
1
1

0
1
1
1

1
1
1
1

0
0
0
0

1
0
0
0

0
1
0
0

1
1
0
0

0
0
1
0

1
0
1
0

0
1
1
0

1
1
1
0

0
0
0
1

1
0
0
1

0
1
0
1

1
1
0
1

0
0
1
1

1
0
1
1

0
1
1
1

1
1
1
1

REPEATER 9

REPEATER A

REPEATER B

REPEATER C

REPEATER D

REPEATER E

ALL REPEATERS

THIS REPEATER
BASE STATION OR
NEXT REPEATER

3A/1A

A.C. IN FUSE

1
0
0
1

OUTPUTS FUSE
BATTERY FUSE (SIREN BUZ. LIGHTS)
4A
2A

USE 1AMP FUSE ONLY


WHEN PROTECTING A
1 Amp TRANSFORMER.

BUZZER
RELAY

0
0
0
1

LIGHTS
RELAY

1
1
1
0

REPEATER 8

DEFAULT = 1.A

0
1
1
0

REPEATER 7

1
0
1
0

REPEATER 6

0
0
1
0

REPEATER 5

1
1
0
0

REPEATER 4

0
1
0
0

REPEATER 3

1
0
0
0

REPEATER 2

0
0
0
0

REPEATER 1

1
0
0
0
0
1
0
1

NO REPEATER

ENTER YOUR SELECTIONS HERE

BIT
N O.

SIREN
RELAY

FA C T O R Y- P R O G R A M M E D D E FA U LT S E T T I N G S

DTMF INPUT
FOR SIXTEM AND STOPKILL
REPEATERS

PROGRAMMING
LINK P

- + - + - + RX 8

MICROCAT
RECEIVER

SNIPER WITH RADIO


COMMUNICATOR

7 6 5 4 3 2 1

AC DISPLAY BAT SPLY TO P.I.R.


17V R C T - + - + - - - + + +

+ RX -

+ RX -

To Program Multi-Repeter on 340A02 PCB with S0012A09 software version.


Do the following:
1. Remove the jumper marked PARALLEL PRG
2. Plug RKF Programmer onto the PRG pins.
3. Press and hold # key on the Programmer.
4. Apply power 12V the 340A02 PCB while holding the #.
5. Release # after 1 second, a dash(-) should appear on the
programmer display.
Follow the programming instructions and proceed as normal.
P2

10+4
10+4+4
CHAMELEON
DTMF
RKU TX
REPEATER
TRANSPONDER
TOPO
TRANSAVER

M000048

:10 DIP-SWITCHES +4 CHANNELS


:10 DIP-SWITCHES +4 CHANNELS +4 REPEATER BITS
:PROGRAMABLE AM TRANSMITTER (REMOTE CONTROL)
:DUAL TONE MULTI FREQUENCY (DATA FORMAT)
:100mW FM TRANSMITTER (1Km REMOTE CONTROL)
:REPEAT AN INCOMING CODE WITHOUT CHANGE
:REPEAT AN INCOMING CODE IN A DIFFERENT FORMAT
:4 CHANNEL AM TRANSMITTER (100M RANGE REMOTE CONTROL)
:REPEATS UHF INPUTS TO VHF OUTPUTS

P7

M000048

261A05

10+4

OR
UCAT 0
GATTO R0
RX (AM)

UHF
RX
10+4+4

INPUT DETECT
TIME

INPUT SIREN
REQUEST
OPEN/CLOSE
REPORT

AS REQUIRED

OR

WHAT TO ENTER

1 = INPUT IS NORMALLY CLOSED


0 = INPUT IS NORMALLY OPEN
FACTORY DEFAULTS

1 = 15 SECOND DETECTION TIME


0 = 0.5 SECOND DETECTION TIME
FACTORY DEFAULTS

1 = INPUT WILL ACTIVATE SIREN


0 = INPUT WILL NOT ACTIVATE SIREN

FACTORY DEFAULTS

1 = INPUT WILL REPORT "OPEN/CLOSE"


0 = NORMAL INPUT

6
7

REPEATER INTRINSIC CODE


(OWN I.D.)

FACTORY DEFAULTS

1 = INPUT WILL REPORT "ALARM/RESTORE"


0 = NORMAL INPUT
FACTORY DEFAULTS

ENTER A 4-DIGIT NUMBER.

FACTORY DEFAULTS

PROGRAMMING THE CHECK-IN TIME


AUTO TEST INTERVAL
(IN HOUR)

- RKU TG1/2/4
- RKU HOG 2/4

- RKU TRS 1/2/4


- RKU TRS HOG 2/4

PROGRAMMING THE IDENTIFICATION REGISTER

- CHAMELEON 1/2/3/4
- TOPO 1/2/3/4 (MAMI)

10+4+4

DTMF
DTMF

OR

INPUT CHANNEL

INPUT
INVERT

ALARM/RESTORE
REPORT

UHF FM_RX
- STING
- TRACER
COMBO
- LYNX

2 - THE CONTENTS OF THAT REGISTER WILL BE DISPLAYED SEQUENTIALLY

REGISTER

265D04 (UHF----> VHF A---> B)


265A07 (UHF---> UHF A--->B)

TO VIEW :
1 - BRIEFLY PRESS THE NUMBER OF THE REGISTER YOU WISH TO VIEW.

IS DISPLAYED

PROGRAMMING THE QD REPORT CODES


1
2
3
4
5
6
7

0
1
2
3
4
5
6
7

- TEST TRANSMITTING
- PANIC
- ALARM ZONES 1-8
- ARM
- DISARM
- MAINS FAILURE
- BATTERY LOW
- NOT USED (SPARE)

FACTORY DEFAULTS (1 HOUR)

FA C T O R Y- P R O G R A M M E D D E FA U LT S E T T I N G S

ENTER YOUR SELECTIONS HERE

BIT
N O.

M000048

VALUE IN HOURS OF INTERVAL


BETWEEN SELF TESTS

( N O T E : D ATA I S E N T E R E D F R O M T O P T O
BOTTOM.)

TO RESET TO FACTORY DEFAULTS:


P6

DATA IS ENTERED FROM LEFT TO RIGHT. THE FACTORY DEFAULT SETTINGS ARE SHOWN BENEATH THE OPTIONS.

REPEATER
SIXTEM

MULTI
REPEATER

RAC +
PRINTER
10+4

MULTI
REPEATER

10+4+4

MULTI
REPEATER

SIXTEM
BASE
STATION
DTMF
(CRAM SOFTWARE)

B
RELAY
EXPANDER

TO PROGRAM :
1- PRESS AND HOLD THE REGISTER NUMBER UNTIL

2 - ENTER A SEQUENCE OF EIGHT

VHF / UHF FM_TX

MULTI REPEATER (SUPPORTED PRODUCTS)

3 TO

PROGRAMMING THE ZONE OPTION REGISTERS

HOLD KEY

P3

UNTIL

IS DISPLAYED

M000048

MULTIREPEATER AS SIXTEM REPEATER

SIXTEM
BASE STATION
(CRAM SOFTWARE)

MULTI
REPEATER

REPEATER

DTMF
10+4+4

FM
RX
AM
RX
(gatto r0)

10+4
261A05

OR

10+4
261A05

MULTI REPEATER AS RKU REPEATER

265A07
10+4

RAC +
PRINTER

- RKU TG1/2/4
- RKU HOG 2/4

UHF
RX

10+4

UHF FM_TX

UCAT 0
GATTO R0
RX (AM)

UHF FM_TX

REPEATER
10+4
- CHAMELEON 1/2/3/4
- TOPO 1/2/3/4 (MAMI)

10+4+4

265A07

10+4

MULTI REPEATER AS TOPO /CHAMELEON REPEATER

DTMF

REPEATER

REPEATER

265A07

DTMF

UHF FM_RX

DTMF

UHF FM_TX

DTMF

UHF FM_RX

- STING
- TRACER
COMBO
- LYNX

265D04 (UHF----> VHF A---> B)


265A07 (UHF---> UHF A--->B)

SIXTEM

MULTI REPEATER(SUPPORTED FORMATS)

MULTI
REPEATER
10+4

RAC +
PRINTER

MULTI
REPEATER

261A05

264A02

MULTI
REPEATER

261A05

MULTI REPEATER AS TRANSAVER WITH


LOCAL MIMIC DISPLAY (RELAY EXPANDER)

MULTI REPEATER AS TRANSAVER

- RKU TG1/2/4
- RKU HOG 2/4

UHF
RX

- CHAMELEON 1/2/3/4
- TOPO 1/2/3/4 (MAMI)

UCAT 0
RX (AM)

10+4

- RKU TRS 1/2/4


- RKU TRS HOG 2/4

10+4+4

UHF FM_RX

MULTI
REPEATER

10+4+4

265D04

VHF FM_TX (15W)

265A07

SIXTEM
BASE STATION
DTMF
(CRAM SOFTWARE)

REPEATER

10+4+4

VHF / UHF FM_TX

10+4+4

REPEATER

- RKU TRS 1/2/4


- RKU TRS HOG 2/4

UHF FM_RX

RELAY
EXPANDER
DTMF

SIXTEM
BASE STATION
(CRAM SOFTWARE)

10+4+4

MULTI
REPEATER

OR

261A05

261A05

P4

M000048

P5

M000048

You might also like