Development of Standard Hooks: Table 1.9 ACI Hook Development Lengths For 3,000 To 5,000 Psi

This document provides standard hook development lengths for reinforcing bars embedded in concrete. It includes a table with hook development lengths in inches for different bar sizes from #3 to #18, based on concrete compressive strengths from 3,000 to 5,000 psi. Notes explain that the lengths are for Grade 60 reinforcing bars in normal-weight concrete and are based on ACI 318 provisions. Modification factors are allowed if certain cover or tie conditions are met.

Uploaded by

Emre Maytalman
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
51 views1 page

Development of Standard Hooks: Table 1.9 ACI Hook Development Lengths For 3,000 To 5,000 Psi

This document provides standard hook development lengths for reinforcing bars embedded in concrete. It includes a table with hook development lengths in inches for different bar sizes from #3 to #18, based on concrete compressive strengths from 3,000 to 5,000 psi. Notes explain that the lengths are for Grade 60 reinforcing bars in normal-weight concrete and are based on ACI 318 provisions. Modification factors are allowed if certain cover or tie conditions are met.

Uploaded by

Emre Maytalman
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Development

ldh of Standard Hooks

Bar Size (d)

lhb = 1200db
f'c

Table 1.9 ACI Hook Development


Lengths for f'c = 3,000 to 5,000 psi
Bar Size

Critical
Section

12db

Bar Size (d)

4d or

4d

2.5" min.
5d
6d

ldh

10/06

General and Technical


Information

General and
Technical Information

#3 through #8
#9, #10 and #11
#14 and #18

#3 [#10]
#4 [#13]
#5 [#16]
#6 [#19]
#7 [#22]
#8 [#25]
#9 [#29]
#10 [#32]
#11 [#36]
#14 [#43]
#18 [#57]

f'
c = 3,000 psi f'
c = 4,000 psi f'
c = 5,000 psi
9
7
7
11
10
9
14
12
11
17
15
13
19
17
15
22
19
17
25
22
19
28
31

24
27

22
24

37
50

32
43

29
39

Notes:
1. Tabulated values are based on Grade 60 reinforcing bars and
normal-weight concrete.
2. Tension development lengths of standard hooks are based on ACI
318-02, Section 12.5. Lengths are in inches.
3. For bar sizes #3 [#10] through #11 [#36] only:
a. If concrete cover conforms to ACI 318-02, Section 12.5.3(a), then
a modification factor of 0.7 may be applied but the resulting length
must not be less than 8db nor 6 in.
b. If hook is enclosed in ties or stirrups conforming to ACI 318-02,
Section 12.5.3(b), then a modification factor of 0.8 may be applied
but the resulting length must not be less than 8db nor 6 in.
4. For epoxy-coated hooks, multiply the tabulated values by 1.2.

You might also like