The document discusses portable vital signs simulators for testing medical equipment in the field. It provides details on the ProSim 3 and ProSim 2 simulators, including their features for ECG, blood pressure, respiration, and other readings. Technical specifications are given for factors like waveforms, connections, battery life, and certifications.
The document discusses portable vital signs simulators for testing medical equipment in the field. It provides details on the ProSim 3 and ProSim 2 simulators, including their features for ECG, blood pressure, respiration, and other readings. Technical specifications are given for factors like waveforms, connections, battery life, and certifications.
The document discusses portable vital signs simulators for testing medical equipment in the field. It provides details on the ProSim 3 and ProSim 2 simulators, including their features for ECG, blood pressure, respiration, and other readings. Technical specifications are given for factors like waveforms, connections, battery life, and certifications.
The document discusses portable vital signs simulators for testing medical equipment in the field. It provides details on the ProSim 3 and ProSim 2 simulators, including their features for ECG, blood pressure, respiration, and other readings. Technical specifications are given for factors like waveforms, connections, battery life, and certifications.
Dont need a comprehensive patient monitor tester? The 6-in-1 ProSim 3 and 4-in-1 ProSim 2 Vital Signs Simulators are clear choices for biomedical engineers and field service techni- cians that need a quality, feature-rich device with high portability. Choose one of these modern vital signs simulators for preventive maintenance, troubleshooting and repair. The ProSim 3 and 2 feature the perfect amount of features for testing in the field. We like to call it the Just Right feature set, and it includes: ECG pacemaker arrhythmia and performance testing respiration invasive blood pressure temperature cardiac output (ProSim 3 only) fetal/maternal (ProSim 3 only) Technical Data Portable, for evaluating the performance of patient monitors in the eld 20 % lighter and 25 % smaller than preceding technology Just Right feature set includes: ECG, pacemaker, arrhythmia and performance testing, respiration, invasive blood pressure, temperature, cardiac output (ProSim 3 only), fetal/ maternal (ProSim 3 only) 43 high-quality waveforms With four IBP channels, ProSim 3 tests even the highest acuity scenarios Stay-connected ECG posts for secure lead connections Improved user interface and online Advantage Training demos Upgraded DIN connectors ensure consistency with the ProSim family; minimize cable compatibility issues Field upgradeable, and easily paired with other devices for comprehensive testing ProSim 3 and 2 are 510(k) approved products Key features 2 Fluke Biomedical ProSim 3 and 2 Vital Signs Simulators Specications General specications Temperature Operating 10 C to 40 C (50 F to +104 F) Storage -25 C to +50 C (-13 F to +122 F) Humidity 10 % to 80 % non-condensing Altitude 2,000 meters (6,562 ft) Dimensions (LxWxH) 14.0 cm x 20.6 cm x 4.5 cm (5.5 in x 8.2 in x 1.8 in) Display LCD greyscale display Communication USB device upstream port Power Two 9 V alkaline batteries Battery life 8 hours continuous operation Weight 0.47 kg (1 lb, 4 oz) Safety standards IEC 61010-1, Pollution degree 2 Certifications CE, CSA, C-TICK N 10140, RoHS Electromagnetic compatibility (EMC) IEC 61326-1; 2006 Detailed specications Normal-sinus-rhythm waveform ECG Reference The ECG amplitudes specified are for Lead II (calibration), from the baseline to the peak of the R wave. All other leads are proportional. Normal sinus rhythm 12-lead configuration with independent outputs referenced to right leg (RL). Output to 10 universal ECG Jacks, color-coded to AHA and IEC Standards Amplitude 0.05 mV to 0.45 mV (0.05 mV steps); 0.5 mV to 5.5 mV (0.5 mV steps) Amplitude accuracy 2 % of setting Lead II. All other leads 5 % ECG rate 30, 40, 45, 60, 80, 90, 100, 120, 140, 160, 180, 200, 220, 240, 260, 280 and 300 BPM Rate accuracy 1 % of setting ECG waveform selection Adult (80 ms) or pediatric (40 ms) QRS duration ST-segment elevation Adult mode only: -0.8 mV to +0.8 mV (0.1 mV steps) Additional steps: +0.05 mV and -0.05 mV Power-on default 80 BPM, 1.0 mV, adult QRS, ST-segment elevation of 0 mV, and a P-R interval of 0.16 seconds Pacemaker waveform Pacer pulse Amplitude 0 (off), 1, 2, 5, 10 mV 10 % for lead II (reference lead) with other leads proportional as for perfor- mance waves. Accuracy Reference lead II: (5 % setting + 0.2 mV) Pacer pulse width 0.1, 0.5, 1.0, 1.5, 2.0 ms 5% 3 Fluke Biomedical ProSim 3 and 2 Vital Signs Simulators Paced arrhythmias Atrial 75 BPM Asynchronous 75 BPM Demand with frequent sinus beats Demand with occasional sinus beats Atrio-ventricular sequential Noncapture (one time) Nonfunction Power-on default Off Arrhythmia Baseline NSR 80 BPM PVC focus Left focus, standard timing (except where specified) Supraventricular arrhythmia Atrial fibrillation (coarse or fine); atrial flutter sinus arrhythmia; missed beat (one time); atrial tachycardia; paroxysmal atrial tachy- cardia; nodal rhythm; and supraventricular tachycardia Premature arrhythmia (All one-time events) Premature atrial contraction (PAC); premature nodal contraction (PNC); PVC1 left ventricular; PVC1 left ventricular, early; PVC1 left ventricular, R on T; PVC2 right ventricularl PVC2 right ventricular, early; PVC2 right ventricular, R on T; and multifocal PVCs Ventricular arrhythmia PVCs 6, 12, or 24 per minute; frequent multifocal PVCs; bigeminy; trigeminy; multiple PVCs (one-time run of 2, 5, or 11 PVCs); ventricu- lar tachycardia; ventricular fibrillation (coarse or fine); and asystole Conduction defect First-, second-, or third-degree AV block; and right- or left-bundle- branch block Power-on default None (off) ECG performance testing Amplitude 0.05 to 0.45 mV (0.05 mV steps), 0.5 to 5.5 mV (0.5 mV steps) Pulse wave 30, 60 BPM, with 60 ms pulse width Square wave 2.0, 0.125 Hz Triangle wave 2.0, 2.5 Hz Sine wave 0.5, 5, 10, 40, 50, 60, 100 Hz R-wave detection waveform Haver-Triangle R-wave rate 30, 60, 80, 120, 200, and 250 BPM R-wave width 20 to 200 ms (10 ms steps) Additional Steps: 8, 10, and 12 ms Rate accuracy 1 % Amplitude accuracy 2 %, Lead II (Exception: 5 % for R waves 20 ms) Power-on default None (off) Fetal/Maternal ECG (ProSim 3 only) Fetal heart rate (Fixed) 60, 90, 120, 140, 150, 210 and 240 BPM Fetal heart rate (IUP) 140 BPM at beginning, then varies with pressure Intrauterine-pressure waveforms Early deceleration, late deceleration, and uniform acceleration Wave duration 90 seconds, bell-shaped pressure curve, from 0 to 90 mmHg and returning to 0 IUP period 2, 3, or 5 minutes; and manual Power-on default FHR 120 BPM, early deceleration, manual 4 Fluke Biomedical ProSim 3 and 2 Vital Signs Simulators Invasive blood pressure Channels 4, each independently settable with identical parameters and are individually electronically isolated from other signals Input/output impedance 300 10 % Exciter input range 2.0 to 16.0 V rms Exciter-input frequency range DC to 5000 Hz Transducer sensitivity 5 or 40 V/V/mmHg Pressure accuracy 2 % of setting + 2 mmHg (valid for dc excitation only) Static Levels, Channel 1 -10, 0, 80, 160, 240, 320, 400 mmHg Static Levels, Channel 2 -10, 0, 50, 100, 150, 200, 240 mmHg Static Levels, Channel 3 (ProSim 3 only) -5, 0, 20, 40, 60, 80, 100 mmHg Static Levels, Channel 4 (ProSim 3 only) -5, 0, 20, 40, 60, 80, 100 mmHg Dynamic waveforms, Channel 1 Arterial: 120/80, Radial Artery: 120/80, Left ventricle: 120/00, Right ventricle: 25/00 Dynamic waveforms, Channel 2 Arterial: 120/80, Radial artery: 120/80, Left ventricle: 120/00, Right atrium (central venous or CVP): 15/10, Right ventricle: 25/00, Pulmonary artery: 25/10, Pulmonary-artery wedge: 10/2, Left atrium: 14/4 Dynamic waveforms, Channel 3 Arterial: 120/80, Radial artery: 120/80, Left ventricle: 120/00, Right atrium (central venous or CVP): 15/10, Right ventricle: 25/00, Pulmonary artery: 25/10, Pulmonary-artery wedge: 10/2, Left atrium: 14/4 Dynamic waveforms, Channel 4 Swan-Ganz sequence, Right atrium (CVP), Right ventricle (RV), Pulmonary artery (PA), Pulmonary-artery wedge (PAW) Respiration artifact BP delta changes from 3 to 16 mmHg Output connector DIN 5-Pin Power-on default 0 mmHg Respiration Rate 0 (OFF), 15, 20, 30, 40, 60, 80, 100, 120 BrPM Waves Normal or ventilated Ratio (inspiration: expiration) Normal 1:1, 1:2, 1:3, 1:4, 1:5 Ventilated 1:1 Impedance variations ( ) 0.2, 0.5, 1 or 3 peak-to-peak variation of lead impedance Accuracy delta 10 % Baseline 500, 1000, 1500, 2000 , Leads I, II, III Accuracy baseline 5 % Respiration lead LA or LL Apnea selection OFF, 12, 22 or 32 seconds (one-time events), or continuous (Apnea ON = respiration OFF) Power-on default 20 BrPM, delta 1.0 , 1000 baseline 5 Fluke Biomedical ProSim 4 Vital Signs Simulator Temperature Temperature 0 C (32 F), 24 C (75.2 F), 37 F (98.6 C), and 40 C (104 F) Accuracy 1 C Compatibility Yellow Springs, Inc. (YSI) Series 400 and 700 Output connector Circular DIN 4-pin Power-on default 0 C (42 F) Cardiac output Catheter type Baxter Edwards, 93a-131-7f Calibration coefficient 0.542 (0 C) injectate), 0.595 (24 C injectate) Blood temperature 37 C (98.6 F) 2 % Injectate volume 10 cc Injectate temperature 0 C or 24 C 2 % value Cardiac output 2.5, 5, 10 liters per minute 5 % Faulty-injectate curve Waveform for simulation available Left-to-right shunt curve Waveform for simulation available Calibrated pulse 1.5 Output connector DIN 7-PIN Power-on default 2.5 liters perminute, 0 C injectate 6 Fluke Biomedical ProSim 3 and 2 Vital Signs Simulators Fluke Biomedical. Better products. More choices. One company. Fluke Biomedical 6045 Cochran Road Cleveland, OH 44139-3303 U.S.A. Fluke Biomedical Europe Science Park Eindhoven 5110 5692EC Son, The Netherlands For more information, contact us: In the U.S.A. (800) 850-4608 or Fax (440) 349-2307 In Europe/M-East/Africa +31 40 267 5435 or Fax +31 40 267 5436 From other countries +1 (440) 248-9300 or Fax +1 (440) 349-2307 Email: [email protected] Web access: www.ukebiomedical.com 2013 Fluke Biomedical. Specications subject to change without notice. Printed in U.S.A. 3/2013 4263771A_EN Modification of this document is not permitted without written permission from Fluke Corporation. About Fluke Biomedical Fluke Biomedical is the worlds leading manufacturer of quality biomedical test and simulation products. In addition, Fluke Biomedical provides the latest medical imaging and oncology quality-assurance solutions for regulatory compliance. Highly credentialed and equipped with a NVLAP Lab Code 200566-0 accredited laboratory, Fluke Biomedical also offers the best in quality and customer service for all your equipment calibration needs. Today, biomedical personnel must meet the increasing regulatory pressures, higher quality standards, and rapid technological growth, while performing their work faster and more effciently than ever. Fluke Biomedical provides a diverse range of software and hardware tools to meet todays challenges. Fluke Biomedical Regulatory Commitment As a medical test device manufacturer, we recognize and follow certain quality standards and certifcations when developing our products. We are ISO 9001 and ISO 13485 medical device certifed and our products are: CE Certifed, where required NIST Traceable and Calibrated UL, CSA, ETL Certifed, where required NRC Compliant, where required Ordering information Models/descriptions ProSim 3 ProSim Vital Signs Simulator ProSim 2 ProSim Vital Signs Simulator Standard accessories ProSim 2/3 Instruction Sheet (multi-language) 4253822 ProSim 2/3 Users Manual CD 614487 Two 9-volt alkaline batteries (minimum 8 hours continuous use) 2392173 IBP Cable, unterminated 2392199 3010-0289FG, CI-3 Cable Assembly (Cardiac Output Box) 1671807 USB cable 2248623 ProSim 2/3 Carrying Case AC power cords 4219453 AC/DC Power Supply 769422 AC Power Cord (Schuko) 284174 AC Power Cord (USA) 769455 AC Power Cord (UK) 658641 AC Power Cord (Australia) 2200218 AC Power Cord (Denmark) 2200229 AC Power Cord (India) 2200241 AC Power Cord (Israel) 2198785 AC Power Cord (Italy) 769448 AC Power Cord (Switzerland) Optional accessories 2523334 YSI 400 Series (UT-4) 2199019 YSI 700 Series (UT-2) 4022300 Cardiac output switch for GE