Type of Piping Systems in Piping Design
Type of Piping Systems in Piping Design
Find out major types of Piping Systems being implemented in Piping Design:
Based on Design Temperature and Pressure
Critical
Main steam piping, HP Bypass system
Hot Reheat System, Cold Reheat System and Low Pressure (LP)
Bypass System
Boiler Feed Water piping
Turbine Extraction system
Steam piping to Turbo driven Boiler Feed Water pump.
Condensate piping
Auxiliary steam piping.
Any system with a design temperature of 400 deg C or higher.
Any system with an ASME flange rating of Class 900 or higher
Other systems which are considered critical because of pressure
and/or Temperature Considerations.
Non Critical
Exclusive of all above
Based on Size
Small Bore
Pipe Diameter less than 65 NB
Large Bore
Equal and greater than 65 NB)
Stress Analysis To be carried out:
High Pressure and above 120 deg C either LB or SB
SB above 120 deg C
Loads on Piping System
Dead load
Weight of the pipe.
Weight of fittings.
Weight of valves and other inline components like strainers, etc.
Weight of insulation.
Weight of fluid flowing inside
Wind load
Seismic load
Hydro Test Loads
Load Due to Thermal Expansion
WHAT MAKES STEAM PIPING CRITICAL
High Temperature and High Pressure of the Steam
Additional Loads on a Steam Line:-
Increased dead load due to higher insulation.
Thermal loads.
Loads due to the phenomena of water hammer/steam hammer.
Relief valve discharge.
Loads due to phenomena of surging.
Temperature
Movement of Equipment Nozzles
Solar Radiation Heating