Electro-Pneumatic Converters TEIP 11, TEIP 11-Ex Specification Sheet
Electro-Pneumatic Converters TEIP 11, TEIP 11-Ex Specification Sheet
Electro-Pneumatic Converters TEIP 11, TEIP 11-Ex Specification Sheet
Electro-pneumatic Converters
TEIP 11, TEIP 11-Ex
18-0.10 EN-IND
Features
Rugged Construction
Resistant to shocks and vibrations
High air capacity, economical air consumption
Arbitary mounting position
Compact design. low weight
IP 65 feild housing made of aluminium
Simple wall or 2 pipe mounting
Explosion protection:
Intrinsically safe to Ex ib IIC or
Explosion Proof Ex d IIA, IIB, IIC
Short response time
Construction and principle of operation
-
The signal converter transforms direct current signals into standard pnuematic signals e.g.
4..20mA into 0.2...1 bar
The principle of conversion is based on the force balance method. Owing to its high shockresistence, the TEIP 11 signal converter is suitable for mounting directly on the valve. An
exceptionally lightweight moving system (100 mg) is used inside the control head of the TEIP 11
signal converter. The signal conversion therefore, is not affected by vibration. External damping,
e.g. with oil, is not required. Intrinsically safe or explosion proof versions with national/international
approval certificates are available for use in hazardous areas.
ABB
Technical Data
Input
Signal ranges
Standard : 4....20mA
On request
0....20 mA
0....10 mA or 10.... 20 mA
4....12 mA or 12.... 20 mA
Input resistence
260 20 ohms at 20OC
Overload Limit
Approx. 30 mA
Output
Signal range
0.2.......1 bar
0.2.......1 kg/cm2
3..........15 psi
Supply : Instrument air at 1.4 0.1 bar
or 1.4 0.1 kg/cm2
or 20 1.5 psi
Signal range (on request)
0.4.......2 bar
0.4.......2 kg/cm2
6..........30 psi
Supply : Instrument air at 2.5 0.1 bar
or 40 1.6 psi
(Further ranges available on request)
Characterstic
Linear, direct action or reverse action.
Out put air capacity
5.2 scfm at 4 bar.
Compressed air
Instrument air free from oil, water and dust
(max. 5 microns)
EMI/RFI
No measurable influence
(acc. to IEC 801)
Step response
10....90% and 90....10% <0.6s
5....15% and 15....5% <0.25s
45....55% and 55....45% <0.2s
85....95% and 95....85% <0.15s
General and safty data
Climatic capabalities
Ambient Temperature
-20....+85OC
For operation in hazardous areas please observe
the specified limits.
Relative Humudity
75% annual average
100% max.
condensation allowed
Connection, housing and mounting
pnuematic connections :
NPT (F) Standard
Electrical connections :
Screw terminals for 2.5mm2
Field housing
Aluminium, colour White : RAL-9002
Cable entry ~ NPT (F)
Degree of protection
Field housing IP 65
Mounting accessories
For wall/2 pipe : standard
Mounting position
Arbitrary
Own consumption
0.2 kg/h = 0.16 Nm3/h = 0.1 scfm
Weight
0.62 kg
Explosion protection
Hysteresis 0.3%
Response sensitivity 0.1%
Influence of variables
Air Supply : < 0.3%/0.1 bar
Ambient Temp. : < 0.05%/K, Zero and span
Vibrations
<1% upto 10g, frequency
10...80 Hz
Mounting Position
<0.5% Zero and span (for 90O change
in position).
Type of protection
Intrinsically safe
- Ex ib IIC T6
- CMRI Certificate No. :CMRS/TC/2100
Frame Proof Enclosure
- Ex d IIA/IIB
CMRI Certificate No. :CMRS/TC/H788
- Ex d IIC
CMRI Certificate No. :CMRS/TC/H779
International Certification optional
at extra cost.
Ordering Data
Catalogue No.
1 8 3 1 1 - 0 -
01
Explosion protection
Without Ex-protection...........................................................................................
Intrinsic safty
Ex ib IIC T6,............................................
Flame proof enclosure
Ex d IIA, IIB.............................................
Flame proof enclosure
Ex d IIC...................................................
18
38
58
48
0 1
Input signal
0....20mA................................................................................................................
4....20mA................................................................................................................
Other (see Suppl. Nos.503,504 and 505).......................................................
1
2
0
Output signal
0.2......1 bar........... ................................................................................................
3....15 psi................................................................................................................
0.2.... 1 kg/cm2.......................................................................................................
Other (See Suppl. Nos.508, 509 and 510)......................................................
1
2
9
0
0 1
01
Characteristic
Direct-action..........................................................................................................
Reverse-action.....................................................................................................
Catalogue No.
1
2
1 8 3 1 1 -0 -
0 1
4.....12mA.................................................
12.....20mA...............................................
Others.......................................................
Suppl. No.
503
504
505
0.4....2bar................................................. 508
6......30psi................................................. 509
Others on request..................................... 510
521
901
902
903
904
905
906
907
- SS Tag Plate......................................................................................................................
908
- SS Name Plate.................................................................................................................
909
911
ABB
ABB Limited
14, Mathura Road,
P.O. Amar Nagar,
Faridabad-121003, Haryana (India)
Phone: 2275592/5593/5597
2276350/6354/6362/6367
Fax: 0129-2275019/2275446
2003 ABB
Printed in India
Monting Arrangement