This document outlines various standards and requirements for traffic signal lights in Greece and Europe, including:
- Minimum luminous intensity and performance levels for signal lights of 100mm, 200mm, and 300mm.
- Requirements for distribution of luminous intensity, luminance uniformity, chromaticity regions, and phantoms.
- Operating voltage, frequency, power, EMC protection, overvoltage protection, and dimensions must meet standards.
- Environmental, temperature, ingress protection, impact resistance, construction integrity, wind load, and mounting requirements are specified.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
104 views2 pages
Requirements Greek Traffic Lights
This document outlines various standards and requirements for traffic signal lights in Greece and Europe, including:
- Minimum luminous intensity and performance levels for signal lights of 100mm, 200mm, and 300mm.
- Requirements for distribution of luminous intensity, luminance uniformity, chromaticity regions, and phantoms.
- Operating voltage, frequency, power, EMC protection, overvoltage protection, and dimensions must meet standards.
- Environmental, temperature, ingress protection, impact resistance, construction integrity, wind load, and mounting requirements are specified.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 2
GREEK NATIONAL STANDARD EUROPEAN STANDARD 100mm 200mm 300mm
Luminous intensity EN 12368, 6.3 ---- >400cd >400cd
Performance level EN 12368, 6.3 ---- class 3/1 or 3/2 class 3/1 or 3/2 Distribution of luminous intensity EN 12368, 6.4 ---- W or M M or N Luminance uniformity EN 12368, 6.5 ---- 1:10 1:15 Chromaticity regions of signal lights EN 12368, 6.7 Phantom signal EN 12368, 6.6 Signal lights with symbols EN 12368, 6.8 Operating Voltage EN 50556 Operating Frequency EN 50556 Maximum power (per colour) EMC EN 50293 Overvoltage protection EN 50556 Dimensions EN 12368, 6.9 ---- class C1 class C1 Environmental requirements EN 12368, 5.1 - EN 60068 Maximum LED Temperature Signal head ingress EN 12368, Table 11 - EN 60529, test 13 and 14 LED module ingress Impact resistance EN 12368, Table 9 - EN 60598-1:2004, 4.13.4 Constructional integrity EN 12368, 7 - EN 60068-2- 64 Test Fh Wind load and deflections (120km/h) - Resistance to horizontal load EN 12899-1:2001 Mounting on the pole EN 12368, 4 Passive safety EN 12767 Deflection EN 12368, 4.4 Wind resistance Signal Head Colour Signal Head Material LED testing EN 60825 LED module Signals EN 50556 Polycarbonate or aluminum alloy of min. 2mm thickness class 1 class AF1 and X1 Green (RAL 6009) IP 55 IP 65 IR 3 According to EN 12368, Table 10 Poles direct mounting: temporary < 2 %, permanent < 0,04 % Poles with bracket / catenary: temporary < 4 %, permanent <0,08 % SAFETY According to EN 12368 According to EN 12368 According to EN 12368 and EN 12899-1 A three-colour-signal heads shall resist in wind velocity of 120 km/h GENERAL 74 o C OPTICAL REQUIREMENTS red-amber-green, Table 7 & 13 class 4 or 5 class S1 or S2 TECHNICAL CHARACTERISTICS 230V AV -15%/+10% 50Hz 2% red-amber-green 17W According to EN 50293 class D0 class A or B Dimming capability LED manufacturer and Signal head manufacturer Marking and labelling EN 12368, 10.1 Test, declarations and requirements EN 12368 Annex A & Annex ZA CE marking and labelling According to EN 12368 TEST, DECLARATIONS & MARKING ISO-9001