0% found this document useful (0 votes)
104 views2 pages

Requirements Greek Traffic Lights

This document outlines various standards and requirements for traffic signal lights in Greece and Europe, including: - Minimum luminous intensity and performance levels for signal lights of 100mm, 200mm, and 300mm. - Requirements for distribution of luminous intensity, luminance uniformity, chromaticity regions, and phantoms. - Operating voltage, frequency, power, EMC protection, overvoltage protection, and dimensions must meet standards. - Environmental, temperature, ingress protection, impact resistance, construction integrity, wind load, and mounting requirements are specified.

Uploaded by

dionkefal3411
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
104 views2 pages

Requirements Greek Traffic Lights

This document outlines various standards and requirements for traffic signal lights in Greece and Europe, including: - Minimum luminous intensity and performance levels for signal lights of 100mm, 200mm, and 300mm. - Requirements for distribution of luminous intensity, luminance uniformity, chromaticity regions, and phantoms. - Operating voltage, frequency, power, EMC protection, overvoltage protection, and dimensions must meet standards. - Environmental, temperature, ingress protection, impact resistance, construction integrity, wind load, and mounting requirements are specified.

Uploaded by

dionkefal3411
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 2

GREEK NATIONAL STANDARD EUROPEAN STANDARD 100mm 200mm 300mm

Luminous intensity EN 12368, 6.3 ---- >400cd >400cd


Performance level EN 12368, 6.3 ----
class 3/1 or
3/2
class 3/1 or 3/2
Distribution of luminous intensity EN 12368, 6.4 ---- W or M M or N
Luminance uniformity EN 12368, 6.5 ---- 1:10 1:15
Chromaticity regions of signal lights EN 12368, 6.7
Phantom signal EN 12368, 6.6
Signal lights with symbols EN 12368, 6.8
Operating Voltage EN 50556
Operating Frequency EN 50556
Maximum power (per colour)
EMC EN 50293
Overvoltage protection EN 50556
Dimensions EN 12368, 6.9 ---- class C1 class C1
Environmental requirements EN 12368, 5.1 - EN 60068
Maximum LED Temperature
Signal head ingress
EN 12368, Table 11 - EN
60529, test 13 and 14
LED module ingress
Impact resistance
EN 12368, Table 9 - EN
60598-1:2004, 4.13.4
Constructional integrity
EN 12368, 7 - EN 60068-2-
64 Test Fh
Wind load and deflections (120km/h) -
Resistance to horizontal load
EN 12899-1:2001
Mounting on the pole EN 12368, 4
Passive safety EN 12767
Deflection EN 12368, 4.4
Wind resistance
Signal Head Colour
Signal Head Material
LED testing EN 60825
LED module Signals EN 50556
Polycarbonate or aluminum alloy of min.
2mm thickness
class 1
class AF1 and X1
Green (RAL 6009)
IP 55
IP 65
IR 3
According to EN 12368, Table 10
Poles direct mounting: temporary < 2 %,
permanent < 0,04 %
Poles with bracket / catenary:
temporary < 4 %, permanent <0,08 %
SAFETY
According to EN 12368
According to EN 12368
According to EN 12368 and EN 12899-1
A three-colour-signal heads shall resist
in wind velocity of 120 km/h
GENERAL
74
o
C
OPTICAL REQUIREMENTS
red-amber-green, Table 7 & 13
class 4 or 5
class S1 or S2
TECHNICAL CHARACTERISTICS
230V AV -15%/+10%
50Hz 2%
red-amber-green 17W
According to EN 50293
class D0
class A or B
Dimming capability
LED manufacturer and Signal head
manufacturer
Marking and labelling EN 12368, 10.1
Test, declarations and requirements
EN 12368 Annex A & Annex
ZA
CE marking and labelling
According to EN 12368