0% found this document useful (0 votes)
80 views5 pages

Atmel Corporation: Tel: (408) 441-0311 Fax: (408) 436-4200

This document provides reliability data for the AT-89S8252 flash memory chip from Atmel Corporation, including the results of various tests of the plastic package version: 1) A 125°C dynamic lifetest on two lots with a total of 200,000 device hours found a best failure rate estimate of 0.01% per 1,000 hours at 50°C ambient. 2) A 150°C retention bake on the same lots with a total of 150,000 device hours found a best failure rate estimate of 0.01% per 1,000 hours at 50°C ambient. 3) A 121°C/15PSG pressure pot test of a 50 device sample found no failures

Uploaded by

wm53
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
80 views5 pages

Atmel Corporation: Tel: (408) 441-0311 Fax: (408) 436-4200

This document provides reliability data for the AT-89S8252 flash memory chip from Atmel Corporation, including the results of various tests of the plastic package version: 1) A 125°C dynamic lifetest on two lots with a total of 200,000 device hours found a best failure rate estimate of 0.01% per 1,000 hours at 50°C ambient. 2) A 150°C retention bake on the same lots with a total of 150,000 device hours found a best failure rate estimate of 0.01% per 1,000 hours at 50°C ambient. 3) A 121°C/15PSG pressure pot test of a 50 device sample found no failures

Uploaded by

wm53
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

PAGE 1 OF 5

ATMEL CORPORATION
Tel:(408)441-0311
Fax:(408)436-4200

AT-89S8252 FLASH RELIABILITY DATA

- 125°C DYNAMIC LIFETEST (PLASTIC)

- 150°C RETENTION BAKE (PLASTIC)

- 121°C/15PSG PRESSSURE POT TEST

- EXTENDED TEMPERATURE CYCLE

JULY 2003

2325 Orchard Parkway San Jose CA. 95131


PAGE 2 OF 5

AT-89S8252

PLASTIC PACKAGE

125°C DYNAMIC LIFETEST

LOT DATE SAMPLE TOTAL NUMBER NUMBER OF


NUMBER CODE SIZE HOURS (K) FAILURES

8A1867-1 8A9841 100 100.0 0

9B0070 9B9925 100 100.0 0

FAILURE RATE

TOTAL DEVICE HOURS 200,000 DEVICE HOURS

BEST ESTIMATE λ = 0.4% PER 1,000 HOURS

50°C AMBIENT EXTRAPOLATION TO 50°C VIA ARRHENNIUS


EQUATION AND ACTIVATION ENERGY OF
0.5eV
λ = 0.01% PER 1,000 HOURS (111 FITS)

CONFIDENCE ESTIMATE λ 60 = 0.01% PER 1,000 HOURS


60% CONFIDENCE (154 FITS)
λ 90 = 0.04% PER 1,000 HOURS
90% CONFIDENCE (390 FITS)
PAGE 3 OF 5

AT-89S8252

PLASTIC PACKAGE

150°C RETENTION BAKE

LOT DATE SAMPLE TOTAL NUMBER NUMBER OF


NUMBER CODE SIZE HOURS (K) FAILURES

8A1867-1 8A9841 100 100.0 0

9B0070 9B9925 50 50.0 0

FAILURE RATE

TOTAL DEVICE HOURS 150,000 DEVICE HOURS

BEST ESTIMATE λ = 0.7% PER 1,000 HOURS

50°C AMBIENT EXTRAPOLATION TO 50°C VIA ARRHENNIUS


EQUATION AND ACTIVATION ENERGY OF
0.5eV
λ = 0.01% PER 1,000 HOURS (98 FITS)

CONFIDENCE ESTIMATE λ 60 = 0.01% PER 1,000 HOURS


60% CONFIDENCE (131 FITS)
λ 90 = 0.03% PER 1,000 HOURS
90% CONFIDENCE (326 FITS)
PAGE 4 OF 5

AT-89S8252

PLASTIC PACKAGE

121°C/15PSG PRESSURE POT TEST

DATE PACKAGE SAMPLE NUMBER OF FAILURES


CODE TYPE SIZE AT INDICATED HOURS

(24) (48) (72) (96)

9B9925 44 PLCC 50 0 0 0 0
PAGE 5 OF 5

AT-89S8252

PLASTIC PACKAGE

EXTENDED TEMPERATURE CYCLE

-65°C to +150°C PLCC/TSOP/SOIC/PDIP


-55°C to +125°c CBGA

DATE PACKAGE SAMPLE NUMBER OF NUMBER OF


CODE TYPE SIZE CYCLES FAILURES

8A9841 44 PLCC 50 1000 0

9A9925 44 PLCC 50 1000 0

You might also like