Quick Selection Table

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

Quick selection table

Contactors ... 9 to 85A


Frame size

9A

12A

18A

22A

3-pole Contactors
See page 26
for more details

Types

AC coil
DC coil

Ratings / IEC60947-4
AC1
AC3
200/240V
380/440V
500/550V
690V
Ratings / UL508
continuous current
single phase 115V
230V
three phase 200V
230V
460V
575V
NEMA size

GMC-9
GMD-9
kW
2.5
4
4
4
hp

A
25
11
9
7
5
A
20

0.5
1
2
2
5
7.5
00

GMC-12
GMD-12
kW
A
25
3.5
13
5.5
12
7.5
12
7.5
9
hp
A
25
0.5
2
3
3
7.5
10
00

GMC-18
GMD-18
kW
A
40
4.5
18
7.5
18
7.5
13
7.5
9
hp
A
30
1
3
5
5
10
15
0

GMC-22
GMD-22
kW
A
40
5.5
22
11
22
15
22
15
18
hp
A
32
2
3
7
7.5
10
15
0

Additional auxiliary contacts

2-pole
Front mount

See page 112


for more details

4-pole
Front mount

2-pole
Side mount

4-pole Contactors
See page 38
for more details

Types

AC coil
DC coil

AC1(A)

GMC-9/4
GMD-9/4
20

See page 38
for more details

GMC-12/4
GMD-12/4
20

GMC-18/4
GMD-18/4
25

GMC-22/4
GMD-22/4
32

Overload Relays
Setting
ranges (A)

Bimetallic style
Type GT

See page 77~88 for more details

Class10A
Class 20

GT-22

Differential
Non-differential (3-heater)
Non-differential (2-heater)
Differential

0.1 - 0.16
0.16 - 0.25
0.25 - 0.4
0.4 - 0.63
0.63 - 1
1 - 1.6
1.6 - 2.5
2.5 - 4

4-6
5-8
6-9
7 - 10
9 - 13
12 - 16
16 - 22

Base for
separate mount

GTK-22
GTH-22/3
GTH-22
GTK-22/L
Setting ranges (A)

Electronic style

0.1 - 1.5
1-5
4.4 - 22

Type GMP
30 adjustable
Class 1
See page 98~106 for more details

16

GMP22

Separate mount type

32A

40A

50A

65A

75A

See page 28
for more details

GMC-32
GMD-32
kW
7.5
15
18.5
18.5
hp

See page 30
for more details

GMC-40
GMD-40
kW
A
60
11
40
18.5
40
22
32
22
23
hp
A
50
3
5
10
10
25
25
1

A
50
32
32
28
20
A
45

2
5
7.5
10
20
20
1

GMC-50
GMD-50
kW
A
80
15
55
22
50
30
43
30
28
hp
A
70
3
7.5
10
15
30
30
2

2-pole
Front mount

GMC-65
GMD-65
kW
A
100
18.5
65
30
65
33
60
33
35
hp
A
80
5
10
15
20
40
40
2

GMC-75
GMD-75
kW
A
110
22
75
37
75
37
64
37
42
hp
A
90
5
15
20
25
50
50
2

4-pole
Front mount

GMC-40/4
GMD-40/4
60

See page 42
for more details

GMC-50/4
GMD-50/4
80

Setting ranges (A)


4-6
5-8
6-9
7 - 10
9 - 13

12 -18
16 - 22
18 - 26
24 - 36
28 - 40

GT-40

GMC-65/4
GMD-65/4
100

Setting
ranges (A)

Base for
separate
mount

GMC-75/4
GMD-75/4
110

7 - 10
9 - 13
12 -18
16 - 22
18 - 26
24 - 36

GMC-85/4
GMD-85/4
135

28 - 40
34 -50
45 - 65
54 - 75
63 - 85
Base for
separate mount

GT-85

GTK-40
GTH-40/3
GTH-40

GTK-85
GTH-85/3
GTH-85

GTK-40/L

GTK-85/L

Setting ranges (A)


4 - 20
8 - 40

GMP40

GMC-85
GMD-85
kW
A
135
25
85
45
85
45
75
45
45
hp
A
100
7.5
15
25
30
50
50
3

2-pole
Side mount

See page 40
for more details

GMC-32/4
GMD-32/4
50

85A

Setting ranges(A) : 16 ~ 80A

separate
mount

GMP80

Separate mount
Wiring by screw

Setting ranges(A) : 5 ~ 60A

GMP60

Separate mount
Wiring by CT tunnel

17

Quick selection table


Contactors ... 100 to 800A
Frame size

100A

125A

150A

3-pole Contactors
See page 32
for more details

Types

AC/DC
common coil

Ratings / IEC60947-4

GMC-100
kW

GMC-125
A

AC1

kW

A
210

200/240V

30

105

37

125

45

150

55

105

60

120

75

150

500/550V

55

85

60

90

90

140

690V

55

65

60

70

90

100

hp

hp

hp

continuous current

three phase

kW

160

380/440V

Ratings / UL508
single phase

GMC-150
A

160

AC3

See page 32
for more details

160

160

210

115V

7.5

10

15

230V

15

20

25

200V

30

40

40

230V

30

40

50

460V

60

75

100

575V

60

75

100

NEMA size
Additional auxiliary contacts

AU-100
1NO+1NC, Side mount

See page 112


for more details

4-pole Contactors
See page 44
for more details

Types

AC/DC
common coil

AC1(A)

GMC-100/4

GMC-125/4

GMC-150/4

160

160

210

Overload Relays

Setting ranges (A)

Setting ranges (A)

Bimetallic style
Type GT
GT- 100

34 - 50
39 - 57
43 - 65
54 - 80
65 - 100
85 - 125

GT- 150

See page 89~97 for more details

Differential
Class10A

Non-differential (3-heater)

Class 20

Differential

Non-differential (2-heater)

18

34 - 50
39 - 57
43 - 65
54 - 80
65 - 100
85 - 125
100 - 150

GTK-100

GTK-150

GTH-100/3

GTH-150/3

GTH-100

GTH-150

GTK-100/L

GTK-150/L

180A

220A

300A

400A

See page 34
for more details

GMC-180
kW

kW

GMC-300
A

800A

See page 34
for more details

GMC-220

230

600A

GMC-400

kW

275

See page 36
for more details

kW

GMC-600
A

350

kW

GMC-800
A

450

kW

660

900

55

180

75

250

90

300

125

400

190

630

220

800

90

180

132

250

160

300

220

400

330

630

440

800

110

180

132

200

160

250

225

350

330

500

500

720

110

120

132

150

200

220

250

300

330

420

500

630

hp

hp

hp

hp

hp

hp

230

275

15

350

450

660

900

15

30

40

60

60

100

125

150

60

75

100

150

200

300

125

150

200

300

400

600

125

150

200

300

400

600

250

AU-100
1NO+1NC, Side mount

See page 44
for more details

See page 46
for more details

See page 46
for more details

GMC-180/4

GMC-220/4

GMC-300/4

GMC-400/4

GMC-600/4

GMC-800/4

230

275

350

450

660

900

Setting ranges (A)

Setting ranges (A)

GT- 220

65 - 100
85 - 125
100 - 150
120 - 180
160 - 240

Setting ranges (A)

85 - 125
100 - 150
120 - 180
160 - 240
220 - 300
260 - 400

GT- 400

220 - 300
260 - 400
400 - 600
520 - 800

GT- 800

GTK-220

GTK-400

GTK-600

GTH-220/3

GTH-400/3

GTH-600/3

GTH-220

GTH-400

GTH-600

GTK-220/L

GTK-400/L

GTK-600/L

19

Quick selection table


Mini contactors & overloads
Mini contactors

3NO main contacts


1 auxiliary contacts

Screw clamp type

Frame size
Screw clamp type

Fast-on type
6A

AC coil

GMC-6M

Cage clamp type

Solder pin type

9A

12A

GMC-9M

GMC-12M

16A
GMC-16M

DC coil

GMD-6M

GMD-9M

GMD-12M

GMD-16M

Fast-on type

AC coil

GMC-6MF

GMC-9MF

GMC-12MF

GMC-16MF

DC coil

GMD-6MF

GMD-9MF

GMD-12MF

GMD-16MF

Cage clamp type

AC coil

GMC-6MC

GMC-9MC

GMC-12MC

GMC-16MC

DC coil

GMD-6MC

GMD-9MC

GMD-12MC

GMD-16MC

AC coil

GMC-6MP

GMC-9MP

GMC-12MP

GMC-16MP

DC coil

GMD-6MP

GMD-9MP

GMD-12MP

Solder pin type


Ratings / IEC60947-4

kW

AC1
AC3

kW

20

kW

20

GMD-16MP

kW

20

200/240V

1.5

2.2

12

15

380/440V

2.2

5.5

12

7.5

16

500/550V

3.7

5.5

690V

hp

hp

hp

hp

Ratings / UL508
continuous current

20

25

30

32

single phase

115V

0.5

0.5

230V

three phase

200V

230V

7.5

460V

7.5

10

10

575V

7.5

10

15

15

00

00

00

NEMA size
Additional auxiliary contacts

See page 108


for more details

A
20

Screw clamp type

Fast-on type

Cage clamp type

2-pole, Front mount

AU-2M

AU-2MF

AU-2MC

4-pole, Front mount

AU-4M

AU-4MF

AU-4MC

2-pole, Side mount

AU-1M

AU-1MF

Solder pin type

AU-1MP

AU-1MC

Overload Relays
Setting
ranges (A)

Bimetallic style
Type GT
Class 10A
GT-12M

Differential

20

0.1 - 0.16
0.16 - 0.25
0.25 - 0.4
0.4 - 0.63
0.63 - 1
1 - 1.6
1.6 - 2.5
2.5 - 4

4-6
5-8
6-9
7 - 10
9 - 13
12 - 16
Base for
separate mount

GTK-12M

Non-differential (3-heater)

GTH-12M/3

Non-differential (2-heater)

GTH-12M

See page 85
for more details

You might also like