WALKWAY STEEL
STRUCTURE CALCULATION
Date: 16 -June-2014
Rev: 00
Table of Contents Page No.
1. INTRODUCTION 3
2 DESIGN CRITERIA 3
3 STAAD 3D MODEL 4
4 SUMMARY AND DISCUSSION 4
APPENDIX-A GRATING DESIGN 5
APPENDIX-B LOAD CALCULATION 8
APPENDIX-C STRUCTURE ANALYSIS AND DESIGN BY STAAD PRO 10
APPENDIX-D BASE PLATE & ANCHOR BOLT DESIGN 62
APPENDIX-E TYPICAL CONNECTION DESIGN 75
APPENDIX A
GRATING DESIGN
APPENDIX B
LOAD CALCULATION
Dead Load Calculation
The self weight of steel (Dead load) has been calculated by STAAD itself.
Form STAAD, the dead load 5% added for connections elements,
1 square meter has been considered for load calculation.
Grating load per square meter
Number of Bearing bar per sqm=(1000/32)+1=32 nos.
Number of cross bar per sqm=(1000/124)+1=9 nos.
Weight of bearing bar per sqm =32x1x0.014=0.448 kN/m2
Weight of cross bar per sqm =9x1x0.003=0.027 kN/m2
Total Dead Load per sqm. = 0.448+.027 = 0.48 kN/m2
Dead load on cross member
Cross member spacing 2.062m
Load due to bearing bar=0.448 kN/m2 x 2.062m= 0.923 kN/m
Weight of cross bar per sqm =0.027 kN/m2 x 2.062 m =0.056 kN/m
Total Dead Load = 0.923+0.056 = 0.98kN/m
Conservatively add 10% for fixation and imperfection =1.08 kN/m
Spacing stair stringer member max.spacing 0.7m
Total Dead Load on stair stringer member = (0.7/2)x0. 48= 0.17 kN/m
Handrail dead load 1.00 kN/m (Conservatively assumed)
Live load on cross member
Live load 4 kN/m2 has been considered as per BS 6399-1914996, Table -1,
Total live load on cross member = 2.062x4 = 8.25 kN/m
Total live load on stair stringer member = (0.7/2)x4= 1.4 kN/m say 1.50kN/m