Eaton: Pressure or Pressure-Flow Compensator Control Adjustment Procedures

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

flow compensator pressure exceeds 15 bar [210 PSI].

Use a gauge that is dampened or glycerine filled. With


the gauge installed and the load sensing valve in the
closed position, start the system
and observe the flow
compensator pressure. If the
reading is other than 13 to 15
bar [190 to 210 PSI],
readjustment of the flow
compensator may be required.
3) To change setting, remove the adjustment screw cover
from the flow compensator valve. Loosen the flow
compensator adjustment screw lock nut with a 7/16 inch
open end wrench.
4) With the system running and
system control valve in the
closed position, use a 1/8 inch
Allen wrench to turn the
adjustment screw to the proper
or desired flow compensated
pressure. Clockwise rotation of the adjustment screw will
increase the pressure setting and counter-clockwise
rotation will decrease the pressure setting. Important: Any
readjustments exceeding the 31 bar [450 PSI] maximum
factory setting must have prior
approval from Eaton Hydraulic
Division or the warranty of the
pump will be void.
5) After adjustments are
complete, hold the adjustment
screw stationary and tighten
the locknut to (torque 8 to 11
Nm [6 to 8 lbfft]).
6) After turning system off, install
the compensator screw cover
and check pressure
compensator settings.
This procedure is used to adjust the compensator on the
Eaton model 70122, 70422, 70423, and 70523
compensated controlled piston pumps.
Model 70422
Left hand rotation shown
1) Pump model 70122 incorporates two gauge ports. The
models 70422 and 70423 may or may not have gauge
ports, its an optional feature. The pump model 70523
does not incorporate gauge ports.
Gauge port size is 3/8-24 UNF-2B. One gauge port is to
check system pressure and the other to check inlet
vacuum. To check system pressure on models without
gauge ports a tee fitting must be installed in the pumps
outlet port. Always adjust flow spool first and than
pressure spool.
Gauge Port
Adjustment end of compensator valve
Pressure Spool
To check or readjust flow compensator valve setting:
2) Install pressure gauge into gauge
port using a 1/2 inch open end wrench
and remove the plug furthest away
from adjustment end of the
compensator valve. A recommended
pressure gauge for checking the flow
compensator is 0 to 21 bar or 0 to 41
bar [0 to 300 PSI or 0 to 600 PSI] if the
No. 2-604
May, 1997 Eaton

Medium Duty Piston Pump


Pressure or Pressure-Flow Compensator
Control Adjustment Procedures
Flow Spool
Flow Signal
Line Port
To check or readjust pressure compensator valve
setting:
7) Install pressure gauge into gauge port use a 1/2
inch open end wrench and remove the plug furthest
away from adjustment end of the
compensator valve.
8) Install a pressure gauge into the
gauge port. A recommended
pressure gauge for checking
system pressure is 0 - 670 bar [0 -
10,000 PSI]. The gauge used
should also be dampened or
glycerine filled. With the gauge
installed, actuate the directional
control valve so that the discharge
of the pump is blocked by the
system load, observe the reading
on the pressure gauge. If the reading is other than the
207 to 214 bar [3000 to 3100 PSI] maximum factory
setting, readjustment of the pressure compensator
valve may be necessary. A lower setting for special
applications may be possible and permissible.
9) To change the compensator
setting, you must first use a
small screwdriver or similar
tool to remove the adjustment
screw cover from the pressure
compensator cap. Note: The
present covers are plastic and
if carefully removed may be
reused. Prior caps were made of aluminum and in most
cases when removed are not reusable.
10) To readjust the pressure
compensator you must first
use a 7/16 inch open end
wrench to loosen the
compensator adjustment screw
lock nut.
11) Next start the pump and
actuate the directional control valve so that the discharge
of the pump is blocked by the system load. Observe the
pressure gauge and use a 1/8 inch Allen wrench and
slowly turn the adjustment screw to obtain the desired
pressure setting. Clockwise rotation of the adjustment
screw will increase the pressure setting and counter-
clockwise rotation will decrease the pressure setting.
Important: Any readjustments exceeding the 207 to 214
bar [3000 to 3100 PSI] maximum factory setting must
have prior approval from Eaton Hydraulic Division or the
warranty of the pump will be void.
12) After readjustment of the
pressure compensator is
completed, hold the
adjustment screw stationary
and tighten the locknut
(Torque 8 to 11 Nm [6 to 8
lbfft]). Remove the load and
install the compensator
screw cover. Remove pressure
gauge and replace the gauge
port (torque 8 to 11 Nm [6 to
8 lbfft]).
B
A
C
B
A
Test Circuit Set Up for
Pressure-Flow Compensators
1) Do not connect the flow signal line to the unit and
leave the flow compensator signal port open.
For 1.16, 2.32, and 2.77in
3
/r pumps: Block flow from
pump using shut - off valve B and set flow
compensator to produce pressure range specified at
point A.
For 4.21 in
3
/r pumps: Set flow compensator for range
specified at an output flow of 5-7 gal/min.
2) Connect flow compensator port downstream of
shut-off valve B with the flow signal line.
3) Open shut-off valve B. Block flow from pump
using shut-off valve C which is downstream from the
flow signal line. Set pressure compensator to produce
a pressure range at point A as specified.
Note: For 1.16 in
3
/r pumps, and 2.32 in
3
/r pumps with
non A-pad backplate, add the inlet pressure to the
pressure setting tolerance.
Test Circuit Set Up for
Pressure Compensators
1) Block flow from pump using shut-off valve B. Set
pressure compensator to produce a pressure range (at
Zero flow).
Note: For 1.16 in3/r pumps, add the inlet pressure to
the pressure compensator setting tolerance. For all
other units, add the case pressure to the pressure
setting tolerance.
Low Pressure Standby
Pressure Flow
Compensator
Spool
Orifice
High Pressure
Compensator
Spool
High Pressure Standby
Operation of System
High Pressure Standby
Eventually, the piston in the cylinder (actuator) reaches the end of
its travel. When it does, flow past the lands of the directional control
spool stops. Pressure equalizes on both sides of the directional control
spool and pressure also equalizes on both ends of the pressure-flow
compensator spool. The 200 PSI spring forces the pressure flow
compensator spool all the way to the left. When pressure reaches 3000
PSI, the high pressure compensator spool moves to the right and directs
oil to the camplate control piston. The piston moves the camplate to
near zero angle and the pump stops producing flow. This is called the
high pressure standby mode.
Low Pressure Standby
Here the spool in the directional control valve has been returned to
neutral. The pressure that was directed to the right end of the pressure-
flow compensator spool is now drained through the orifice in the control
valve. The pump will stroke back to near zero displacement and
practically no flow is produced. The 200 PSI acting on the left end of the
pressure-flow compensator spool will be offset by the 200 PSI spring
acting on the right end of the spool. The spool will modulate back and
forth to maintain 200 PSI in the discharge circuit of the pump.
Eaton Corporation
Hydraulics Division
15151 Hwy. 5
Eden Prairie, MN 55344
Telephone 612/937-9800
Fax 612/937-7130
Eaton Ltd.
Hydraulics Division
Glenrothes, Fife
Scotland, KY7 4NW
Telephone 01-592-771-771
Fax 01-592-773-184
Eaton GmbH
Hydraulics Products
Am Schimmersfeld 7
40880 Ratingen, Germany
Telephone 02102-406-830
Fax 02102-406-800
ISO-9001 CERTIFICATED FIRM
DET NORSKE VERITAS INDUSTRY BV, THE NETHERLANDS
ACCREDITED BY
THE DUTCH COUNCIL
FOR CERTIFICATION
Reg. No. 24
Quality System Certified
Products in this catalog are manufactured
in an ISO-9001-certified site.
www.eaton.com

You might also like