0% found this document useful (0 votes)
1K views2 pages

HETP Preliminary Calculation

The document describes Norton's Correlation equation for calculating the height equivalent to a theoretical plate (HETP) based on a liquid's surface tension, viscosity, and type of random packing. It provides the input data for a liquid with a surface tension of 29.57 dyne/cm and viscosity of 0.54 cP. Using this data in the equation along with a packing constant of 1.1308 results in a calculated HETP of 1.442284 feet or 0.439608 meters. Design safety factors of 20% or 15% can be applied depending on the number of theoretical stages required for separation.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
1K views2 pages

HETP Preliminary Calculation

The document describes Norton's Correlation equation for calculating the height equivalent to a theoretical plate (HETP) based on a liquid's surface tension, viscosity, and type of random packing. It provides the input data for a liquid with a surface tension of 29.57 dyne/cm and viscosity of 0.54 cP. Using this data in the equation along with a packing constant of 1.1308 results in a calculated HETP of 1.442284 feet or 0.439608 meters. Design safety factors of 20% or 15% can be applied depending on the number of theoretical stages required for separation.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 2

Norton's Correlation : ln HETP = n - 0.187 ln + 0.

213 ln
= Surface Tension
= viscosity
n = constant related to type of random packing
Applicable when,
liquid phase surface tension > 4 dyne/cm & < 36 dyne/cm
liquid viscosity > 0.08 cP & < 0.83 cP
Input Data
Liquid-phase
Surface Tension, = 29.57 dyne/cm
Liquid Viscosity = 0.54 cP
n = 1.1308 Please do not change this value
Calculation
ln HETP = 0.366228
HETP = 1.442284 ft
= 0.439608 m
For separations, less than 15 theoritical stages, a 20% design safety factor can be applied.
For separations, requiring 15 to 25 theoritical stages, a 15% design safety factor can be applied.
For separations, requiring 15 to 25 theoritical stages, a 15% design safety factor can be applied.