This document summarizes the heat loss calculation for an insulated storage tank. The tank is 3.75 meters in diameter, has 6.7 meters of liquid height, and 100 mm thick insulation. At an outside temperature of -10 degrees C and internal liquid temperature of 122 degrees C, the total heat loss is calculated to be 8 kW. A heating coil with a diameter of 60 mm and total surface area of 24.1 m2 would be required to maintain the internal liquid temperature above 122 degrees C over a 120 hour heating period.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
150 views2 pages
Tank Heat Loss (Incl. Tank Heating)
This document summarizes the heat loss calculation for an insulated storage tank. The tank is 3.75 meters in diameter, has 6.7 meters of liquid height, and 100 mm thick insulation. At an outside temperature of -10 degrees C and internal liquid temperature of 122 degrees C, the total heat loss is calculated to be 8 kW. A heating coil with a diameter of 60 mm and total surface area of 24.1 m2 would be required to maintain the internal liquid temperature above 122 degrees C over a 120 hour heating period.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 2
TANK HEAT LOSS
(incl. tank heating)
Case: Diameter 3.75 m Liquid height 6.7 m Insulation thickness 100 mm Insulation thermal conductivity 0.06 W/m K Liquid density 1060 kg/m Liquid viscosity bulk 10.0 cP Liquid viscosity @ Tw 50.0 cP Liquid specific heat 1.75 kJ/kg K Bulk temperature To 122.0 C Lowest bulk temperature allowed 122.0 C Outside temperature T l -10.0 C Ground temperature T b 0.0 C Wall temperature Tw Estimate 60.0 C Wall temperature Tw Calculated 60.3 C Film temperature Tf 91.0 C Heat transfer coefficient wall-bulk 26.24 W/m K Heat transfer coefficient wall-air 23.00 W/m K Overall HTC wall 0.54 W/m K Overall HTC roof 0.38 W/m K Overall HTC bottom 1.30 W/m K Heat loss wall 5673 W Heat loss roof 556 W Heat loss bottom 1752 W
Total heat loss 8.0 kW Heating time tank contents 120 h Heating requirement 0.0 kW Total heating capacity 8.0 kW Heating coil diameter 60.0 mm
Temperature heating medium 140.0 C Temperature heating coil wall 130.0 C Temperature liquid film T film 126.0 C Liquid viscosity @ T film 85.0 cP Heat transfer coefficient coil-bulk 41 W/m K Heating coil area 24.1 m Heating coil length 127.8 m \\vboxsrv\conversion_tmp\scratch_2\[239038407.xls.ms_office.xls]a 07/21/14 @ 01:08 Reference: Opslag van stookolie; Technische informatie, T.I. 7701 154/4