PLC Connection Manual
PLC Connection Manual
AIBUS ........................................................................................................................................ 5
Allen-Bradley CompactLogix / FlexLogix ................................................................................ 8
Allen-Bradley DF1 ................................................................................................................... 12
Allen-Bradley DF1 BCC .......................................................................................................... 14
Allen-Bradley DH485 .............................................................................................................. 16
Allen-Bradley EtherNet/IP CompactLogix .............................................................................. 19
Allen-Bradley EtherNet/IP (DF1) ............................................................................................ 22
Allen Bradley EtherNet/IP-Tag (CompactLogix/ControlLogix) ............................................. 25
Allen Bradley PLC5 ................................................................................................................. 29
Altus ALNET-I ........................................................................................................................ 32
Baumuller Servo....................................................................................................................... 34
Cimon CM1-CP4A................................................................................................................... 36
Cimon CM1-SC02A................................................................................................................. 38
Copley Controls ....................................................................................................................... 40
CROUZET M3 (FBD) ............................................................................................................. 42
CROUZET M3 (LAD) ............................................................................................................. 44
Danfoss ECL Apex20 Controller ............................................................................................. 46
Danfoss FC series ..................................................................................................................... 48
Danfoss VLT2800 Series ......................................................................................................... 50
DELTA DVP ............................................................................................................................ 52
EMERSON PLC EC20 ............................................................................................................ 54
FATEK FB series ..................................................................................................................... 56
Fuji NB Series PLC .................................................................................................................. 59
GE Fanuc CMM ....................................................................................................................... 61
GE Fanuc SNP-X ..................................................................................................................... 64
GE Fanuc Series 90-30 (Ethernet) ........................................................................................... 67
HAN YOUNG .......................................................................................................................... 70
Heng Yuan Sensor.................................................................................................................... 71
HITACHI EH-SIO ................................................................................................................... 73
HITACHI EHV ........................................................................................................................ 76
HITACHI H series (CPU port) ................................................................................................ 78
HUST H4X............................................................................................................................... 82
IAI X-SEL ................................................................................................................................ 84
IDEC ........................................................................................................................................ 87
INOVANCE H2U/H1U ........................................................................................................... 90
Intelligent Servo ....................................................................................................................... 92
JUSTFI Controller .................................................................................................................... 93
KERNEL SISTEMI ................................................................................................................. 95
1
AIBUS
UDIAN Automation AI-501, AI-518, AI-519, AI-701, AI-702M, AI-704M, AI-706M, AI-719
http://www.yudian.us
HMI Setting:
Parameters
PLC type
Com port
Baud rate
Parity bit
Data Bits
Stop Bits
HMI Station No.
PLC Station No.
Recommend
AIBUS
RS485 2W
9600
None
8
2
0
1
Online Simulator
YES
NO
Option
RS232
9600, 19200
0-100
PLC Setting:
Communication mode
Notes
Device address:
AI-518
Bit/Word
Device Type
Format
Range
Memo
00H
dd
01H
dd
-1999~+9999
HIAL
02H
dd
-1999~+9999
LoAL
03H
dd
0~9999
dHAL
04H
dd
0~9999
dLAL
05H
dd
0~2000
dF
06H
dd
0~4
CtrL
07H
dd
0~9999
M5
08H
dd
1~9999
09H
dd
0~2000
10
0AH
dd
0~125
CtI
11
0BH
dd
0~37
Sn (read only)
12
0CH
dd
0~3
13
0DH
dd
-1999~+9999
dIL
14
0EH
dd
-1999~+9999
dIH
15
0FH
dd
0~9999
ALP
16
10H
dd
-1999~+4000
0.1
17
11H
dd
0~48
Op1
18
12H
dd
-110~+110%
oPL
19
13H
dd
0~110%
oPH
20
14H
dd
0~127
SV/STEP
dd
21
15H
Sc
CF (read only)
Baud ratebAud
0~19.2K
/808Pstatus word:
run:0 suspend:4 stop:12
(read only)
22
16H
dd
0~100
ADDR
23
17H
dd
0~20
dL
24
18H
dd
0~127
Run
25
19H
dd
0~9999
Loc
AI-701
Bit/Word
Device Type
Format
Range
Memo
01H
dd
-9990~+30000
HIAL
02H
dd
-9990~+30000
LoAL
03H
dd
-9990~+30000
HdAL
04H
dd
-9990~+30000
LdAL
05H
dd
0~2000
AHYS
11
0BH
dd
0~37
12
0CH
dd
0~3
dPt
13
0DH
dd
-9999~+30000
SCL
14
0EH
dd
-9999~+30000
SCH
15
0FH
dd
0~4444
AOP
16
10H
dd
-1999~+4000
0.1
Scb
17
11H
dd
0~48
Opt
dd
21
15H
Baud ratebAud
0~19.2K
22
16H
dd
0~80
ADDR
23
17H
dd
0~40
FILt
25
19H
dd
0~255
Loc
Wiring diagram:
RS-485:
MT8000 PLC[485]
AI-518/518P
9P D-SUB
RS485 port
COM1
COM3
RX-
Data-
COMM A
RX+
Data+
COMM B
GND
GND
Driver Version:
Version
Date
Description of Changes
7
V1.20
Dec/30/2008
HMI Setting:
Parameters
Recommend
PLC type
Allen-Bradley
Option
CompactLogix/FlexLogix
Com port
RS232
Baud rate
19200
Parity bit
None
Data Bits
Stop Bits
1-31
PLC Setting:
Communication mode
Notes
Device address:
Bit/Word
Device Type
Format
Range
B_BOOL
fffddd(dd)
Memo
Bit data file
N_BOOL
fffddd(dd)
DW
DW
fffddd
fffddd
fffddd
Cx.PRE
DW
fffddd
Timer
Accumulator
Value
(T4,
T10~255)
Counter Preset Value (C5, C10~255)
DW
Cx.ACC
F8_REAL
ddd
Fx_REAL
fffddd
DW
Nx_INT
Fffddd
Floating
COM2
COM3
3 TX
2 RX
5 GND
4 TX
6 RX
5 GND
7 TX
8 RX
5 GND
AB CPU CH0
RS-232
9P D-SUB Male
2
3
5
file
Wiring diagram:
COM1
data
F010~F255)
MT8000 RS232
9P D-SUB Female
point
RD
TD
GND
(F008,
10
Driver Version:
Version
Date
V1.20
Dec/30/2008
Description of Changes
11
Allen-Bradley DF1
Allen-Bradley MicroLogix 1000, 1100, 1200, 1500, SLC 5/03, 5/04, 5/05
http://www.ab.com
Note: Allen-Bradley DF1 driver is used CRC checksum.
HMI Setting:
Parameters
PLC type
Com port
Baud rate
Parity bit
Data Bits
Stop Bits
HMI Station No.
PLC Station No.
Recommend
AB DF1
RS232
19200
None
8
1
0
1
Option
Notes
PLC Setting:
Communication mode
Device address:
Bit/Word
B
B
B
B
B
Device Type
I1
O0
S_Bit
B3
B10~13
Format
ddd(dd)
ddd(dd)
ddd(dd)
ddd(dd)
ddd(dd)
Bfn
fffddd(dd)
NfnBit
fffddd(dd)
W
W
S
T4SV
TfnSV
ddd
ddd
fffddd
T4PV
TfnPV
ddd
fffddd
C5SV
CfnSV
ddd
fffddd
C5PV
ddd
W
W
W
W
W
W
Range
ddd:0~254
(dd): 0~15
ddd:0~254
(dd): 0~15
ddd:0~254
(dd): 0~15
ddd:0~254
(dd): 0~15
ddd:0~254
(dd): 0~15
File no. fff: 3, 10~254
Element no. ddd: 0~254
Bit no. (dd): 0~15
File no. fff: 7, 10~254
Element no. ddd: 0~254
Bit no. (dd): 0~15
ddd:0~254
ddd:0~254
File no. fff: 4, 10~254
Element no. ddd:0~254
ddd:0~254
File no. fff: 4, 10~254
Element no. ddd:0~254
ddd:0~254
File no. fff: 5, 10~254
Element no. ddd:0~254
ddd:0~254
12
Memo
Input (I)
Output (O)
Status (S) bit level
Bit data file (B3)
Bit data file (B10~13)
Bit data file (B3, 10~254)
Bit/Word
Device Type
Format
fffddd
CfnPV
W
W
W
N7
N10~15
F8
ddd
ddd
ddd
Nfn
fffddd
Range
File no. fff: 5, 10~254
Element no. ddd:0~254
ddd:0~254
ddd:0~254
ddd:0~254
File no. fff:0~254
Element no. ddd:0~254
Memo
Counter Accumulator Value
Integer data file (N7)
Integer data file (N10~15)
Floating point data file (F8)
Integer data file (N7, 10~254)
Wiring diagram:
RS-232: MicroLogix 1000, 1100, 1200, 1500
MicroLogix RS232
mini-DIN 8pin
MT8000 RS232
9P D-SUB
COM1
COM2
COM3
3 TX
2 RX
5 GND
4 TX
6 RX
5 GND
7 TX
8 RX
5 GND
RXD
TXD
GND
MT8000 RS232
9P D-SUB Female
COM1
COM2
COM3
3 TX
2 RX
5 GND
4 TX
6 RX
5 GND
7 TX
8 RX
5 GND
2
3
5
RD
TD
GND
Driver Version:
Version
Date
V2.10
Apr/17/2009
Description of Changes
13
HMI Setting:
Parameters
PLC type
Com port
Baud rate
Parity bit
Data Bits
Stop Bits
HMI Station No.
PLC Station No.
Recommend
AB DF1
RS232
19200
None
8
1
0
1
Option
Notes
PLC Setting:
Communication mode
Device address:
Bit/Word
B
B
B
B
B
Device Type
I1
O0
S_Bit
B3
B10~13
Format
ddd(dd)
ddd(dd)
ddd(dd)
ddd(dd)
ddd(dd)
Bfn
fffddd(dd)
NfnBit
fffddd(dd)
W
W
S
T4SV
TfnSV
ddd
ddd
fffddd
T4PV
TfnPV
ddd
fffddd
C5SV
ddd
W
W
W
W
Range
ddd:0~254
(dd): 0~15
ddd:0~254
(dd): 0~15
ddd:0~254
(dd): 0~15
ddd:0~254
(dd): 0~15
ddd:0~254
(dd): 0~15
File no. fff: 3, 10~254
Element no. ddd: 0~254
Bit no. (dd): 0~15
File no. fff: 7, 10~254
Element no. ddd: 0~254
Bit no. (dd): 0~15
ddd:0~254
ddd:0~254
File no. fff: 4, 10~254
Element no. ddd:0~254
ddd:0~254
File no. fff: 4, 10~254
Element no. ddd:0~254
ddd:0~254
14
Memo
Input (I)
Output (O)
Status (S) bit level
Bit data file (B3)
Bit data file (B10~13)
Bit data file (B3, 10~254)
Bit/Word
Device Type
CfnSV
Format
fffddd
C5PV
CfnPV
ddd
fffddd
W
W
W
N7
N10~15
F8
ddd
ddd
ddd
Nfn
fffddd
Range
File no. fff: 5, 10~254
Element no. ddd:0~254
ddd:0~254
File no. fff: 5, 10~254
Element no. ddd:0~254
ddd:0~254
ddd:0~254
ddd:0~254
File no. fff:0~254
Element no. ddd:0~254
Memo
Counter Preset Value
Counter Accumulator Value (C5)
Counter Accumulator Value
Integer data file (N7)
Integer data file (N10~15)
Floating point data file (F8)
Integer data file (N7, 10~254)
Wiring diagram:
RS-232: MicroLogix 1000, 1100, 1200, 1500
MicroLogix RS232
mini-DIN 8pin
MT8000 RS232
9P D-SUB
COM1
COM2
COM3
3 TX
2 RX
5 GND
4 TX
6 RX
5 GND
7 TX
8 RX
5 GND
RXD
TXD
GND
MT8000 RS232
9P D-SUB Female
COM1
COM2
COM3
3 TX
2 RX
5 GND
4 TX
6 RX
5 GND
7 TX
8 RX
5 GND
2
3
5
RD
TD
GND
Driver Version:
Version
Date
V2.10
Apr/17/2009
Description of Changes
15
Allen-Bradley DH485
Allen-Bradley MicroLogix 1000, 1100, 1200, 1500, SLC 5/03, 5/04, 5/05
http://www.ab.com
HMI Setting:
Parameters
Recommend
PLC type
Allen-Bradley DH485
Com port
RS485 2W
RS232
Baud rate
19200
9600, 19200
Parity bit
Even
Data Bits
Stop Bits
1-31
Online Simulator
YES
NO
Option
Notes
PLC Setting:
Communication mode
16
Device address:
Bit/Word
Device
Type
Format
Range
Memo
I1
ddd(dd)
ddd:0~254
(dd): 0~15
Input (I)
O0
ddd(dd)
ddd:0~254
(dd): 0~15
Output (O)
B3
ddd(dd)
ddd:0~254
(dd): 0~15
B10~13
ddd(dd)
ddd:0~254
(dd): 0~15
Bfn
fffddd(dd)
fffddd(dd)
10~254)
S_Bit
ddd(dd)
T4SV
ddd
ddd:0~254
T4PV
ddd
ddd:0~254
C5SV
ddd
ddd:0~254
C5PV
ddd
ddd:0~254
TfnSV
fffddd
Status file
fffddd
CfnSV
fffddd
CfnPV
fffddd
N7
ddd
ddd:0~254
N10~15
ddd
ddd:0~254
F8
ddd
ddd:0~254
Nfn
fffddd
ddd
17
Status file
Wiring diagram:
RS-485: SLC500 Fixed type, SLC5/01,02,03 CH1.
MT8000 cant connect to 1747-AIC PERIPHERAL PORT
AB SLC500 DH485
RJ8 clip style ports
MT8000 RS485
9P D-SUB
COM1
COM3
1 RX2 RX+
5 GND
6 Data9 Data+
5 GND
2
1
SDB
SDA
GND
RS-232: MicroLogix 1000, 1100, 1200, 1500 must set DH485 protocol.
MicroLogix RS232
mini-DIN 8pin
MT8000 RS232
9P D-SUB
COM1
COM2
COM3
3 TX
2 RX
5 GND
4 TX
6 RX
5 GND
7 TX
8 RX
5 GND
RXD
TXD
GND
MT8000 RS232
9P D-SUB Female
COM1
COM2
COM3
3 TX
2 RX
4 TX
6 RX
7 TX
8 RX
GND
GND
GND
2
3
RD
TD
GND
Driver Version:
Version
Date
V1.20
Apr/17/2009
Description of Changes
18
HMI Setting:
Parameters
Recommend
PLC type
Allen-Bradley EtherNet
Option
Notes
(CompactLogix)
Com port
Ethernet
Port no.
44818
PLC Setting:
Communication mode
Device address:
Bit/Word
Device Type
Format
Range
Memo
Bx_BOOL
ffddd(dd)
Nx_BOOL
ffddd(dd)
Bx_INT
fffddd
Nx_INT
fffddd
F8_REAL
ddd
ddd:0~255
Fx_REAL
fffddd
19
ddd:0~255
DW
DW
DW
DW
Tx.PRE
fffddd
fffddd
Cx.PRE
fffddd
T10~255)
Cx.ACC
C10~255)
Wiring diagram:
Ethernet:
MT8000 Ethernet
Wire color
RJ45
RJ45
TX+
White/Orange
RX+
TX-
Orange
RX-
RX+
White/Green
TX+
BD4+
Blue
BD4+
BD4-
White/Blue
BD4-
RX-
Green
TX-
BD3+
White/Brown
BD3+
BD3-
Brown
BD3-
Wire color
RJ45
RJ45
TX+
White/Orange
RX+
TX-
Orange
RX-
RX+
White/Green
TX+
BD4+
Blue
BD4+
BD4-
White/Blue
BD4-
RX-
Green
TX-
BD3+
White/Brown
BD3+
BD3-
Brown
BD3-
RJ45
connector
Driver Version:
Version
Date
V1.10
Dec/30/2008
Description of Changes
21
HMI Setting:
Parameters
Recommend
PLC type
Option
Notes
Com port
Ethernet
44818
PLC Setting:
Communication mode
Device address:
Bit/Word
Device
Type
Format
Range
Memo
I1
ddd(dd)
ddd:0~254
(dd): 0~15
Input (I)
O0
ddd(dd)
ddd:0~254
(dd): 0~15
Output (O)
B3
ddd(dd)
ddd:0~254
(dd): 0~15
Bfn
fffddd(dd)
NfnBit
fffddd(dd)
10~254)
T4SV
ddd
ddd:0~254
T4PV
ddd
ddd:0~254
C5SV
ddd
ddd:0~254
C5PV
ddd
ddd:0~254
N7
ddd
ddd:0~254
Nfn
fffddd
32bit Float
F8
ddd
32bit Float
Ffn
fffddd
DW
Lfn
fffddd
Wiring diagram:
Ethernet: Direct connect (crossover cable)
COM
CPU
PWR
RS232 DF1
Ethernet
Crossover cable
Micro Logix 1000, 1200,
MT8000
MT8000 Ethernet
1761-NET-ENI
Wire color
RJ45
RJ45
TX+
White/Orange
RX+
TX-
Orange
RX-
RX+
White/Green
TX+
BD4+
Blue
BD4+
BD4-
White/Blue
BD4-
RX-
Green
TX-
BD3+
White/Brown
BD3+
BD3-
Brown
BD3-
23
Ethernet:
Switch Hub
MT8000
SLC 500
MT8000 Ethernet
Wire color
SLC 500
SLC 500
RJ45
RJ45
TX+
White/Orange
RX+
TX-
Orange
RX-
RX+
White/Green
TX+
BD4+
Blue
BD4+
BD4-
White/Blue
BD4-
RX-
Green
TX-
BD3+
White/Brown
BD3+
BD3-
Brown
BD3-
Driver Version:
Version
Date
V1.9
Apr/17/2009
V2.00
Dec/21/2009
Description of Changes
24
RJ45
connector
HMI Setting:
Parameters
Recommend
Option
PLC type
Com port
Ethernet
Port no.
44818
PLC Setting:
Communication mode
25
Notes
2. Create Tags.
26
5. In object dialog, select PLC, click Tag and select a controller tag.
27
Device address:
PLC Data Type Name
BOOL
INT
Bit/Word
Boolean
Integer
Memo
DINT
Double Integer
32-bit signed
-231~(231-1)
REAL
32-bit Float
IEEE 754
-32768~32767
Wiring diagram:
Ethernet:
MT8000 Ethernet
RJ45
Wire color
TX+
White/Orange
RX+
TX-
Orange
RX-
RX+
White/Green
TX+
BD4+
Blue
BD4+
BD4-
White/Blue
BD4-
RX-
Green
TX-
BD3+
White/Brown
BD3+
BD3-
Brown
BD3-
Wire color
TX+
White/Orange
RX+
TX-
Orange
RX-
RX+
White/Green
TX+
BD4+
Blue
BD4+
BD4-
White/Blue
BD4-
RX-
Green
TX-
BD3+
White/Brown
BD3+
BD3-
Brown
BD3-
28
RJ45
connector
HMI Setting:
Parameters
Recommend
Option
Notes
PLC type
AB PLC5
Com port
RS232
Baud rate
19200
9600, 19200
Parity bit
None
Data Bits
Stop Bits
1-31
PLC Setting:
Communication mode
Device address:
Bit/Word
Device Type
Format
Range
I1
ddd(dd)
ddd:0~254
(dd): 0~15
Input (I)
O0
ddd(dd)
ddd:0~254
(dd): 0~15
Output (O)
B3
ddd(dd)
ddd:0~254
(dd): 0~15
B10~13
ddd(dd)
ddd:0~254
(dd): 0~15
T4SV
ddd
ddd:0~254
T4PV
ddd
ddd:0~254
C5SV
ddd
ddd:0~254
C5PV
ddd
ddd:0~254
N7
ddd
ddd:0~254
N10~15
ddd
ddd:0~254
F8
ddd
ddd:0~254
Nfn
fffddd
W
W
Memo
fffddd
Bit/Word
Device Type
Format
Range
Memo
newer)
Allen-Bradley PLC-5 Family PLCs using the DF1 Full Duplex protocol.
For the PLC-5/10, PLC-5/15 and PLC-5/25 the MT8000 should be connected to:
the DF1 port on the 1785-KE module;
for the PLC-5/11, PLC-5/20, PLC-5/30 and PLC-5/40 the MT8000 should be connected to:
the Channel 0 Port on the PLC.
Wiring diagram:
RS-232: PLC5 CPU CH0
EasyView MT8000
9P D-SUB
25P D-SUB
3
2
5
3
2
7
TX
RX
GND
4 TX
6 RX
5 GND
7 TX
8 RX
5 GND
Driver Version:
Version
Date
V1.20
Apr/17/2009
Description of Changes
30
RXD
TXD
GND
31
Altus ALNET-I
Altus SeriesMode : PO3042, PO3142, PO3242, PO3342, PL103 ,PL104,
PL105, QK800, QK801, QK2000.
HMI Setting:
Parameters
Recommend
PLC type
Altus ALNET-I
Com port
RS232
Station no.
Baud rate
9600
Parity bit
even
Data Bits
Stop bit
Option
Notes
Device address:
Bit/Word
Device Type
Format
Range
Device Range
M_Bit
dddd(h)
0~ 1023f
Memories
ddd(h)
0 ~ 511f
Auxiliary Relays
ddd(h)
0 ~ 511f
Input Relays
D_Bit
dddd(dd)
0 ~ 102331
Decimals
F_Bit
dddd(dd)
0 ~ 102331
Reals
I_Bit
dddd(dd)
0 ~ 102331
Integers
ddd(h)
0 ~ 511f
Output Relays
dddd
0 ~ 1023
Memories
DW
dddd
0 ~ 1023
Decimals
DW
dddd
0 ~ 1023
Reals
DW
dddd
0 ~ 1023
Integers
TM
hhhh
DW
TD
hhhh
DW
TF
hhhh
DW
TI
hhhh
0 ~ FFFF
0 ~ FFFF
0 ~ FFFF
0 ~ FFFF
Memory Tables
Decimal Tables
Real Tables
Integer Tables
, , , I types are X.
B address range is 0 ~ FF and A address range is 0 ~ FF; the device type is AABB, the range is depend on
the PLC settings.
For example Model PO3242 range is 0 and B range is 0 ~ 7.
32
Wiring diagram:
PLC PO3042, PO3142, PO3242, PO3342
MT8000 RS232 9P D-SUB
COM1
COM2
COM3
RJ45 Port
TX
TX
TX
RX
RX
RX
RX
TX
GND
GND
GND
GND
COM1
COM2
COM3
9P D-SUB
TX
TX
TX
RX
RX
RX
RX
TX
GND
GND
GND
GND
PLC QK800,QK801,QK2000.
MT8000 RS232 9P D-SUB
COM1
COM2
COM3
9P D-SUB
TX
TX
TX
RX
RX
RX
RX
TX
GND
GND
GND
GND
Driver Version:
Version
Date
V0.01
Jul/24/2009
Description of Changes
33
Baumuller Servo
http://www.baumuller.com/
HMI Setting:
Parameters
Recommend
Option
PLC type
Baumuller
Com port
RS485 4W COM1
Baud rate
19200
9600, 19200
Parity bit
Even
Data Bits
7 or 8
Stop Bits
1 or 2
Notes
Defaults
RK 512 Protocol
19200 8 1 EVEN
Device address:
Bit/Word
Device Type
Format
Range
Device Range
DB0_bit
ddd(h)
DB0
ddd
ddd:0~255
34
DB0_bit~DB29_bit
DB0~DB29
Wiring diagram:
RS-485 4W:
MT8000 HMI COM1
RS485 4W 9P D-SUB
Baumuller servo
RS-422 9P D-SUB
Female
Female
1
RX-
1 TXD-
RX+
9 TXD+
TX-
5 RXD-
TX+
6 RXD+
GND
8 GND
Driver Version:
Version
Date
V1.10
Apr/17/2009
Description of Changes
35
Cimon CM1-CP4A
Cimon CM1 series, CP4A module
http://www.kdtsys.com
HMI Setting:
Parameters
Recommend
Option
PLC type
Cimon CM1-CP4A/ECO1A
Com port
RS232
Notes
38400
Data bit
Parity bit
None
Stop bit
PLC Setting:
Bit/Word
Device type
Format
Range
Memo
dd(h)
0 ~ 23F
dd(h)
0 ~ 23F
ddd(h)
0 ~ 511F
ddd(h)
0 ~ 127F
dddd
0 ~ 1023
dddd
0 ~ 1023
ddd(h)
0 ~ 127F
ddd(h)
0 ~ 127F
dddd
0 ~ 4999
dd
0 ~ 99
TS
dddd
0 ~ 1023
TC
dddd
0 ~ 1023
CC
dddd
0 ~ 1023
CS
dddd
0 ~ 1023
36
Read only
Max. range: 99
Wiring diagram:
EasyView MT8000 HMI
9P D-SUB
CM1-CP4A
6P RJ-11 Female
TX
RX
GND
4 TX
6 RX
5 GND
7 TX
8 RX
5 GND
3
2
5
Driver Version:
Version
Date
V1.00
Nov/30/2009
Description of Changes
37
RXD
TXD
GND
6P RJ-11 Female
Cimon CM1-SC02A
Cimon CM series, SC02A module
http://www.kdtsys.com
HMI Setting:
Parameters
Recommend
Option
PLC type
Cimon CM1-SC02A
Com port
RS232
Notes
RS485, RS232
38400
Data bit
Parity bit
None
Stop bit
PLC Setting:
Bit/Word
Device type
Format
Range
Memo
dd(h)
0 ~ 23F
dd(h)
0 ~ 23F
ddd(h)
0 ~ 511F
ddd(h)
0 ~ 127F
dddd
0 ~ 1023
dddd
0 ~ 1023
ddd(h)
0 ~ 127F
ddd(h)
0 ~ 127F
dddd
0 ~ 4999
dd
0 ~ 99
TS
dddd
0 ~ 1023
TC
dddd
0 ~ 1023
CC
dddd
0 ~ 1023
CS
dddd
0 ~ 1023
38
Read only
Max. range: 99
Wiring diagram:
Cimon CM1-SC02A
RS-232
9P D-SUB Male
MT8000 RS232
9P D-SUB Female
COM1
COM2
COM3
3 TX
2 RX
5 GND
4 TX
6 RX
5 GND
7 TX
8 RX
5 GND
2
3
5
RD
TD
GND
Driver Version:
Version
Date
V1.00
Nov/30/2009
Description of Changes
39
Copley Controls
Digital Servo Driver & Controllers, Xenus, Xenus Micro, Accelnet, Accelnet Micro, Stepnet series
http://www.copleycontrols.com/motion/
HMI Setting:
Parameters
PLC type
Com port
Baud rate
Parity bit
Data Bits
Stop Bits
HMI Station No.
PLC Station No.
Recommend
Copley Controls
RS232
9600
None
8
1
0
0
Option
Notes
9600~115200
Even, Odd, None
8
1
0-127
PLC Setting:
ASCII format
Device address:
Bit/Word
W
W
W
W
Device Type
Flash INT 16
RAM INT 16
Flash INT 32
Format
hhh
hhh
hhh
RAM INT 32
hhh
Range
0~FFF
0~FFF
0~FFF
0~FFF
Memo
For Register is INT16 or U16
For Register is INT16 or U16
For Register is INT32 or U32
For Register is INT32 or U32
Wiring diagram:
Xenus, Xenus Micro, Accelnet
Xenus Micro Panel
RS-232 RJ11
J7 cable connector
MT8000 RS232
9P D-SUB
COM1
3
2
5
COM2
TX
4 TX
RX
6 RX
GND 5 GND
COM3
7 TX
8 RX
5 GND
2
5
3, 4
40
RXD
TXD
GND
Stepnet
Stepnet
RS232 RJ11
J8 cable connector
MT8000 RS232
9P D-SUB
COM1
3
2
5
COM2
TX
4 TX
RX
6 RX
GND 5 GND
COM3
7 TX
8 RX
5 GND
2
5
3, 4
RXD
TXD
GND
Accelnet Micro
Accelnet Micro Panel
RS-232
J5 cable connector
MT8000 RS232
9P D-SUB
COM1
3
2
5
COM2
TX
4 TX
RX
6 RX
GND 5 GND
COM3
7 TX
8 RX
5 GND
14
29
15
RXD
TXD
GND
Driver Version:
Version
Date
V1.20
Dec/30/2008
Description of Changes
41
CROUZET M3 (FBD)
HMI Setting:
Parameters
Recommend
Option
PLC type
CROUZET M3 (FBD)
Com port
RS232
Baud rate
115200
Data bit
Parity bit
EVEN
Stop bit
Station no.
Notes
Device address:
Bit/Word
Device Type
Format
Range
Memo
SLI_Bit
dd(f)
1(0)~24(f)
SLO_Bit
dd(f)
25(0)~48(f)
IA
dd
1 ~ 99
SL_IN
dd
1~24
SL_OUT
dd
25~48
Wiring diagram:
MT8000 RS232
9P D-SUB Male
CROUZET M3
RS-232
9P D-SUB Female
(Extension cable)
COM1
3 TX
2 RX
5 GND
3
2
5
RD
TD
GND
DTR
RTS
42
43
CROUZET M3 (LAD)
HMI Setting:
Parameters
Recommend
Option
PLC type
CROUZET M3 (LAD)
Com port
RS232
Baud rate
115200
Data bit
Parity bit
EVEN
Stop bit
Station no.
Notes
Device address:
Bit/Word
Device Type
Format
Range
Memo
dd
1 ~ 99
Input (default: 1 ~ 4)
dd
1 ~ 99
Output (default: 1 ~ 4)
dd
1 ~ 28
Relay
SLI_Bit
dd(f)
1(0)~24(f)
SLO_Bit
dd(f)
25(0)~48(f)
IA
dd
1 ~ 99
dd
1 ~ 12
Timer
dd
1 ~ 16
Counter
SL_IN
dd
1~24
SL_OUT
dd
25~48
44
Wiring diagram:
MT8000 RS232
9P D-SUB Male
CROUZET M3
RS-232
9P D-SUB Female
(Extension cable)
COM1
3 TX
2 RX
5 GND
3
2
5
RD
TD
GND
DTR
RTS
45
HMI Setting:
Parameters
Recommend
PLC type
Com port
RS232
Baud rate
9600
Parity bit
None
Data Bits
Stop Bits
Option
Notes
Device address:
Device Type
Format
Range
Flag
DDDD
0-8191
Input
DDD
0-511
Output
DDD
0-511
Register
DDDD
0-4095
Counter
DDDD
0-1599
Timer
DDDD
0-1599
Reg_Float
DDDD
0-4095
Memo
EB8000 device addresses range may different with PLC extended mode, please refer EB8000s
addresses range as above.
ddd:Decimal
46
Wiring diagram:
RS232:
MT8000 RS232
9P D-SUB Male
COM1
COM2
COM3
3
2
5
7 TX
8 RX
5 GND
TX
RX
GND
4 TX
6 RX
5 GND
ECL Apex20
Controller
9P D-SUB Female
2 RXD
3 TXD
5 GND
7 RTS
8 CTS
RS485:
MT8000 RS-485
9P D-SUB Female
COM1
COM3
1 RX6 Data2 RX+
9 Data+
ECL Apex20
Controller
Port# 1
11
12
MT8000 RS-485
9P D-SUB Female
COM1
COM3
1 RX6 Data2 RX+
9 Data+
ECL Apex20
Controller
Port# 0
29
28
Driver Version:
Version
Date
V1.10
Dec/30/2008
Description of Changes
47
Danfoss FC series
FC051, FC100, FC200, FC300, VLT Micro Driver.
http://www.danfoss.com/
HMI Setting:
Parameters
Recommend
PLC type
Danfoss FC Series
Com port
RS485
Baud rate
9600
Parity bit
Even
Data Bits
Stop Bits
Option
Notes
Device address:
Bit/Word
Device Type
Format
Range
Memo
Word
Parameter
09
DDD
0-1000
Set Parameter
Dword
Reference
10
DDD
0-0
Dword
Para_Index
11
DDD(DD)
0-999999
Set Parameter(Index)
Wiring diagram:
RS485:
MT8000 RS-485
9P D-SUB Female
FC RS485
COM1
COM3
RX-
Data-
69
RX+
Data+
68
Driver Version:
Version
Date
V1.00
Mar/05/2010
Description of Changes
49
HMI Setting:
Parameters
Recommend
Option
PLC type
Com port
RS485 2W
RS485 2W
Baud rate
9600
9600
Parity bit
Even
Even
Data Bits
Stop Bits
Notes
0-126
According to PLC
PLC Setting:
Communication mode
Device address:
Bit/Word
W
DW
Device Type
Reference
Parameter
Format
dd
ddd
Range
0
ddd:0~1000
Memo
Control Bus Reference
Set Parameter
Wiring diagram:
RS-485:
VLT2800 RS485
MT8000 RS485
9P D-SUB
COM1
COM3
1 RX2 RX+
5 GND
6 Data9 Data+
5 GND
69
68
50
DD+
Driver Version:
Version
Date
V1.10
Otc/06/2008
Description of Changes
51
DELTA DVP
DELTA DVP series
http://www.deltadriver.com
HMI Setting:
Parameters
Recommend
Option
PLC type
DELTA DVP
Com port
RS232
RS232, RS485
Baud rate
9600
9600, 19200
Parity bit
Even
Data Bits
7, 8
Stop Bits
Notes
0-255
PLC Setting:
Communication mode
Device address:
Bit/Word
Device Type
Format
Range
ooo
0 ~ 23417 (Octal)
Input
ooo
0 ~ 23417 (Octal)
Output
dddd
0 ~ 9999
Auxiliary Relay
dddd
0 ~ 9999
Step Relay
dddd
0 ~ 9999
Timer
dddd
0 ~ 9999
Counter
TV
dddd
0 ~ 9999
Timer
CV
ddd
0 ~ 127
Counter
CV2
ddd
232 ~ 255
dddd
0 ~ 9999
Data Register
52
Memo
Wiring diagram:
1. RS232: CPU port
DELTA DVP CPU
port
8p mini DIN
MT8000 RS232
9P D-SUB
COM1
COM2
COM3
3 TX
4 TX
7 TX
2 RX
6 RX
8 RX
5 GND 5 GND 5 GND
4
5
3/8
RXD
TXD
GND
8Pin Mini-Din Female
MT8000 RS232
COM1
COM3
1 RX2 RX+
6 Data9 Data+
Driver Version:
Version
Date
V1.00
Dec/30/2008
Description of Changes
53
HMI Setting:
Parameters
Recommend
Option
PLC type
Com port
RS232
Notes
RS232, RS422,
RS485
Baud rate
9600
9600,
19200,115200
Parity bit
Even
Data Bits
7 or 8
Stop Bits
1 or 2
0-255
PLC Setting:
Communication mode
Modbus RTU
protocol
Device address:
Bit/Word
Device Type
Format
Range
ooo
0-377 octal
256point
0000-0255
ooo
0-377 octal
256point
1200-01455
dddd
0-1999
2000-3999
SM
ddd
0-255
4400-4655
ddd
0-991
6000-6991
ddd
0-255
8000-8255
ddd
0-255
9200-9455
dddd
0-7999
0000-7999
SD
ddd
0-255
8000-8255
dd
0-15
8500-8515
54
Memo
0000-0255
ddd
0-255
9000-9255
ddd
0-199
9500-9699
DW
C_Double
ddd
200-255
9700-9811
DW
D_Double
dddd
0-7998
0000-7999
Wiring diagram:
MT8000 RS232
Emerson EC20
9P D-SUB Male
COM1
COM1
COM2
COM3
3 TX
2 RX
5 GND
4 TX
6 RX
5 GND
7 TX
8 RX
5 GND
RXD
TXD
GND
Driver Version:
Version
Date
V1.10
Dec/30/2008
Description of Changes
55
FATEK FB series
FATEK FBs series, FB MC series, FB MA series need FB-DTBR converter.
http://www.fatek.com/
HMI Setting:
Parameters
Recommend
Option
PLC type
FATEK FB Series
Com port
RS232
Baud rate
9600
Parity bit
Even
Data Bits
Stop Bits
RS232/RS485/Ethernet
Notes
0-255
PLC Setting:
Communication mode
Device address:
Bit/Word
Device Type
Format
Range
ddd
ddd : 0~9999
Input
ddd
ddd : 0~9999
Output
ddd
ddd : 0~9999
Internal Relay
ddd
ddd : 0~9999
Step Relay
ddd
ddd : 0~9999
Timer
ddd
ddd : 0~9999
Counter
ddd
ddd : 0~9999
Data Register
ddd
ddd : 0~9999
Data Register
RT
ddd
ddd : 0~9999
Timer Register
RC
ddd
ddd : 0~9999
Counter Register
DW
DRT
ddd
ddd : 0~9999
DW
DRC
ddd
ddd : 0~9999
56
Memo
Wiring diagram:
1. RS232: FBs Port0
FBs
MT8000 RS232
COM1
3
2
5
COM2
4P Mini-Din Male
COM3
TX
4 TX
7 TX
RX
6 RX
8 RX
GND 5 GND 5 GND
RX
TX
GND
MT8000 RS232
COM1
COM2
module
COM3
9P D-SUB Male
3
2
5
TX
4 TX
7 TX
RX
6 RX
8 RX
GND 5 GND 5 GND
RX
TX
GND
MT8000 RS-485] 2w
COM1
COM3
3P Terminal Block
1
RX-
Data-
D-
RX+
Data+
D+
MT8000 RS232
COM1
3
2
5
COM2
COM3
TX
4 TX
7 TX
RX
6 RX
8 RX
GND 5 GND 5 GND
RX
TX
GND
RTS
CTS
MT8000 RS-485 2w
COM1
COM3
RX-
Data-
D-
RX+
Data+
D+
57
4P
Mini-Din
Female
Driver Version:
Version
Date
V1.20
Jul/09/2009
Description of Changes
58
HMI Setting:
Parameters
Recommend
PLC type
Fuji NB Series
Com port
RS485 4W
Baud rate
19200
Parity bit
Odd
Data Bits
Stop Bits
Option
Notes
PLC Setting:
Communication mode
Device address:
Bit/Word
Device Type
Format
Range
hhh
0~7ff
Output Relay
hhh
0~3ff
Input Relay
hhh
0~fff
Internal Relay
hhh
0~fff
Latch Relay
hh
0-ff
Counter
M_Spe
hhhh
8000-81ff
hhh
0-1ff
Timer
CV
hhh
0-3ff
Counter value
TV
hhh
0-3ff
Timer value
hhhh
0-1fff
Data Register
D_Spe
hhhh
8000-80ff
59
Memo
Special Relay
Special Register
Wiring diagram:
MT8000 HMI
FUJI NB Series
COM1 [RS485]4w
9P D-SUB
RJ45 8p connector
1
2
3
4
5
4 TX3 TX+
6 RX5 RX+
RXRX+
TXTX+
GND
Driver Version:
Version
Date
V1.10
May/05/2009
Description of Changes
60
GE Fanuc CMM
http://www.ge.com
HMI Setting:
Parameters
Recommend
Option
Notes
PLC type
GE Fanuc CMM
Com port
RS232
RS232/RS485
Baud rate
19200
9600,19200,38400,57600,115200
Parity bit
Odd
Data Bits
7,8
Stop Bits
1, 2
0-255
0-255
PLC Setting:
Refer to related PLC manual
Device address:
Bit/Word
Device Type
Format
Range
ddd
1-10000
Input relay
ddd
1-10000
Output relay
ddd
1-10000
Auxiliary relay
ddd
1-7680
ddd
1-256
AI
ddd
1-10000
AQ
ddd
1-10000
ddd
1-32640
Data register
SA
ddd
1-128
SB
ddd
1-128
SC
ddd
1-128
ddd
1-128
61
Memo
Wiring diagram:
CPU port(90-30/VersaMax)
MT8000 COM1[485]
90-30/VersaMax
9P D-SUB
RS485 port
15P SUB-D Female
RX-
12
SDA
RX+
13
SDB
GND
GND
TX-
10
RDA
TX+
11
RDB
RT
RTSA
15
CTSA
RTSB
14
CTSB
90-30/90-70 series
9P D-SUB Female
RS232
port
6P RJ-11 Female
3
TX
RX
RX
TX
GND
GND
6P RJ-11 Female
MT8000 RS232
VersaMax series
9P D-SUB
COM1
COM2
COM3
RS232 port
9P SUB-D Female
TX
TX
TX
RX
RX
RX
RX
TX
GND
GND
GND
GND
COM1
COM2
COM3
VersaMax series
RS232 port
9P SUB-D Female
TX
TX
TX
RX
RX
RX
RX
TX
GND
GND
GND
GND
MT8000 RS232
9P D-SUB
62
Driver Version:
Version
Date
V1.00
20090709
Description of Changes
63
GE Fanuc SNP-X
GE Fanuc 90 & VersaMax series PLC
http://www.ge.com
HMI Setting:
Parameters
Recommend
Option
Notes
PLC type
GE Fanuc SNP-X
Com port
RS485 4w
RS232/RS485
Baud rate
19200
9600,19200,38400,57600,115200
Parity bit
Odd
Data Bits
7,8
Stop Bits
1, 2
0-255
0-255
PLC Setting:
Refer to related PLC manual
Device address:
Bit/Word
Device Type
Format
Range
ddd
1-10000
Input relay
ddd
1-10000
Output relay
ddd
1-10000
Auxiliary relay
ddd
1-7680
ddd
1-256
AI
ddd
1-10000
AQ
ddd
1-10000
ddd
1-32640
Data register
SA
ddd
1-128
SB
ddd
1-128
SC
ddd
1-128
ddd
1-128
64
Memo
Wiring diagram:
Memo
90 VersaMax series PLC of GE FANUC includes such series as 90-30, 90-70, VersaMax Micro, VersaMax
Nano and VersaMax,etc., CPU of 90-30series can pass RS485 serial com port on module, utilize SNP serial
communication protocol of GE to connect with EasyView MT8000HMI, In addition,
CPU331/340/341/350/351/352/360/363/364 can also connect through CMM311 Communication Module,
CPU351/352/363/364 also can connect through serial com port on CPU Unit 90-70 series CPU can also connect
through CMM711 Communication Module or connect through serial com port on CPU Unit Relevant software and
hardware are set up concretely please consult the technical manual that GE GE Fanuc offered.
CPU port(90-30/VersaMax)
MT8000 COM1[485]
90-30/VersaMax
9P D-SUB
RS485 port
15P SUB-D Female
RX-
12
SDA
RX+
13
SDB
GND
GND
TX-
10
RDA
TX+
11
RDB
RT
RTSA
15
CTSA
RTSB
14
CTSB
90-30/90-70 series
9P D-SUB Female
RS232
port
6P RJ-11 Female
3
TX
RX
RX
TX
GND
GND
6P RJ-11 Female
VersaMax series
RS232 port
MT8000 RS232
9P D-SUB
COM1
COM2
COM3
9P SUB-D Female
TX
TX
TX
RX
RX
RX
RX
TX
GND
GND
GND
GND
65
COM1
COM2
COM3
VersaMax series
RS232 port
9P SUB-D Female
TX
TX
TX
RX
RX
RX
RX
TX
GND
GND
GND
GND
MT8000 RS232
9P D-SUB
Driver Version:
Version
Date
V1.20
Jan/09/2009
Description of Changes
66
HMI Setting:
Parameters
Recommend
PLC type
Com port
Ethernet
Port No.
18245
Option
Notes
1~99
Device address:
Bit/Word
Device type
Format
Range
I_bit
dddd
1 ~ 2048
Q_bit
dddd
1 ~ 2048
M_bit
dddd
1 ~ 4096
G_bit
dddd
1 ~ 1280
T_bit
ddd
1 ~ 256
SA_bit
dd
1 ~ 32
Read Only
SB_bit
dd
1 ~ 32
Read Only
SC_bit
dd
1 ~ 32
Read Only
S_bit
dd
1 ~ 32
Read Only
dddd
1 ~ 2033
dddd
1 ~ 2033
dddd
1 ~ 4081
dddd
1 ~ 1256
ddd
1 ~ 241
SA
dd
1 ~ 17
SB
dd
1 ~ 17
67
Memo
SC
dd
1 ~ 17
dd
1 ~ 17
dddd
1 ~ 9999
AI
dddd
1 ~ 2048
AQ
ddd
1 ~ 512
Wiring diagram:
Ethernet:
MT8000 Ethernet Wire color
Ethernet Hub or
RJ45
Switch RJ45
RX+
TX+
White/Orange
TX-
Orange
RX+
White/Green
TX+
BD4+
Blue
BD4+
BD4-
White/Blue
BD4-
RX-
Green
TX-
BD3+
White/Brown
BD3+
BD3-
Brown
BD3-
68
RX-
RJ45
connector
TX+
White/Orange
RX+
TX-
Orange
RX-
RX+
White/Green
TX+
BD4+
Blue
BD4+
BD4-
White/Blue
BD4-
RX-
Green
TX-
BD3+
White/Brown
BD3+
BD3-
Brown
BD3-
Driver Version:
Version
Date
V1.20
Jun/29/2009
Description of Changes
69
HAN YOUNG
Temperature Controller
http://hynux.com/kor/
HMI Setting:
Parameters
PLC type
Recommend
Heng Young Seires
Option
Notes
Com port
RS485 4W
Baud rate
9600
Parity bit
None
Data Bits
7 or 8
Stop Bits
1 or 2
0-255
Device address:
Bit/Word
B
W
Device Type
I
D
Format
ddd
ddd
Range
1-699
1-699
Wiring diagram:
MT8000 PLC[485]
Han Young
RS485
RX-
32
TX-
RX+
31
TX+
TX-
34
RX-
TX+
33
RX+
Driver Version:
Version
Date
V1.20
May/20/2009
Description of Changes
70
Memo
HMI Setting:
Parameters
PLC type
Recommend
Heng Yuan Sensor
Com port
RS485 2W
Baud rate
9600
Parity bit
Even
Data Bits
Stop Bits
Option
Notes
1-31
Online Simulator
YES
YES
PLC Setting:
Communication mode
Device address:
Bit/Word
W
Device Type
Parameter
Format
ddd
Range
ddd:0~1000
Memo
Wiring diagram:
EU05 series
MT8000 PLC[485]
RS485 port
9P D-SUB
COM1
COM3
RX-
Data-
RX- (Yellow)
RX+
Data+
RX+ (Green)
GND
GND
GND (Black)
71
Driver Version:
Version
Date
V1.00
Dec/30/2008
Description of Changes
72
HITACHI EH-SIO
HMI Setting:
Parameters
Recommend
PLC type
HITACHI
Option
Notes
EH-SIO
Com port
RS232
RS232, RS485
Baud rate
19200
Parity bit
Even
Even
Data Bits
Stop Bits
PLC Setting:
Communication
mode
19200,E,7,1(default)
Select
Device address :
Device
Bit/Word
B
B
B
B
B
B
Type
X
Format
Range
hhhh(h)
hhhh: 0~FFFF
Memo
External Input-bit(X)
(h):0~F
Y
hhhh(h)
hhhh: 0~FFFF
(h):0~F
External Output-bit(Y)
hhhh(h)
hhhh: 0~FFFF
(h):0~F
Data area-bit(M)
hhhh(h)
hhhh: 0~FFFF
Timer(T)
(h):0~F
R
hhhh(h)
hhhh: 0~FFFF
Internal Output(R)
(h):0~F
L
hhhh(h)
hhhh: 0~FFFF
73
Link area-bit(L)
(h):0~F
W
TC
hh
hh: 0~FF
WX
hhhh
hhhh: 0~270F
External Input-word(X)
WY
hhhh
hhhh: 0~270F
External Output-word(Y)
WR
hhhh
hhhh: 0~270F
Internal Output-word(R)
WL
hhhh
hhhh: 0~270F
Link area-word(L)
WM
hhhh
hhhh: 0~270F
Data area-word(M)
Wiring diagram:
EH-SIO port1/port 2 RS232
MT8000 RS-232
HITACHI EH-SIO
9P D-SUB
port1 / port 2
8pin RJ45 Male
COM1
COM2
COM3
TX
TX
TX
6 RD
RX
RX
RX
5 SD
GND
GND
GND
1 SG
Port 1 / Port 2
CTS
8 RS
8pin RJ45
Female
4 PHL
7 DR
Hitachi EH-SIO
PLC RS485port
9PinD-SUB FEMALE
1
2
3
4
5
RXRX+
TXTX+
GND
5
4
6
7
1
74
TXTX+
RXRX+
SG
Hitachi EH-SIO
RX-
TX-
RX+
TX+
TX-
RX-
TX+
RX+
GND
SG
75
HITACHI EHV
HITACHI Web site: http://www.hitachi-ies.co.jp/english/products/plc/index.htm
HMI Setting:
Parameters
PLC type
recommend
Option
Notes
HITACHI
EHV
Com port
Ethernet
Port no.
3004
3004~3007
Device address:
Bit/Word
Device type
Format
Range
Memo
hhhh(h)
0~FFFF(F)
External Input-bit(X)
hhhh(h)
0~FFFF(F)
External Output-bit(Y)
hhhh(h)
0~FFFF(F)
Data area-bit(M)
ddddd
0~65535
Timer(T)
hhhh(h)
0~FFFF(F)
Internal Output(R)
hhhh(h)
0~FFFF(F)
Link area-bit(L)
TC
dddd
0~2559
WX
hhhh
0~FFFF
External Input-word(X)
WY
hhhh
0~FFFF
External Output-word(Y)
WR
hhhh
0~FFFF
Internal Output-word(R)
WL
hhhh
0~73FF
Link area-word(L)
WM
hhhh
0~7FFF
Data area-word(M)
76
Wiring diagram:
Ethernet:
MT8000 Ethernet
RJ45
Wire color
TX+
White/Orange
RX+
TX-
Orange
RX-
RX+
White/Green
TX+
BD4+
Blue
BD4+
BD4-
White/Blue
BD4-
RX-
Green
TX-
BD3+
White/Brown
BD3+
BD3-
Brown
BD3-
Wire color
TX+
White/Orange
RX+
TX-
Orange
RX-
RX+
White/Green
TX+
BD4+
Blue
BD4+
BD4-
White/Blue
BD4-
RX-
Green
TX-
BD3+
White/Brown
BD3+
BD3-
Brown
BD3-
Driver Version:
Version
Date
V1.00
Jan/12/2010
Description of Changes
77
RJ45
connector
Model
HITACHI
EH-150, Micro-EH, H20, H40, H64, H200, H250, H252, H300, H302, H700, H702, H1000,
H series
HMI Setting:
Parameters
Recommend
PLC type
HITACHI
Option
Notes
H-Series
Com port
RS232
RS232, RS485
Baud rate
19200
Parity bit
Even
Even
Data Bits
Stop Bits
0-255
0-255
Online Simulator
YES
NO
Broadcast command
PLC Setting:
Communication mode
19200,E,7,1(default)
Select
78
NO
Device address:
Bit/Word
Device
Type
Format
Range
Memo
hhh(h)
External Input-bit(X)
hhh(h)
External Output-bit(Y)
hhh(h)
Data area-bit(M)
hhh(h)
Timer(T)
hhh(h)
Internal Output(R)
hhh(h)
Link area-bit(L)
TC
hhh
hhh: 0~FF
WX
hhh
hhh: 0~270F
External Input-word(X)
WY
hhh
hhh: 0~270F
External Output-word(Y)
WR
hhh
hhh: 0~270F
Internal Output-word(R)
WL
hhh
hhh: 0~270F
Link area-word(L)
WM
hhh
hhh: 0~270F
Data area-word(M)
Wiring diagram:
WARNING: If your communications cable is not wired exactly as shown in our cable assembly instructions, damage
to the MT8000 or loss of communications can result.
CPU TYPE
Port 1
Port 2
EH-150/CPU 104A
RS-232
RS-232
EH-150/CPU 208A
RS-232
RS-232
Port 1
EH-150/CPU 308A
RS-232/RS-485
RS-232
Port 2
EH-150/CPU 316A
RS-232/RS-485
RS-232
EH-150/CPU 448A
RS-232/RS-485
RS-232
Switch Number
1
OFF
Normal mode
OFF
TRNS0 operation
3, 4
5
6
ON
ON
4,800 bps
OFF
ON
9,600 bps
ON
OFF
19,200 bps
OFF
OFF
38,400 bps
ON
Dedicated port
PHL
Doesnt support
Default
ON
Low
9,600 bps
ON
High
38,400 bps
OFF
Low
4,800 bps
Doesnt support
OFF
High
19,200 bps
Default
OFF
(System mode)
OFF
(System mode)
Toggle-Switch
PHL
Low
PHL
High
HITACHI EH-150
9P D-SUB
port1 / port 2
8pin RJ45 Male
COM1
COM2
COM3
TX
TX
TX
6 RD
RX
RX
RX
5 SD
GND
GND
GND
1 SG
CTS
8 RS
4 PHL
7 DR
Hitachi EH-150
port1
8PinRJ45port
1
2
3
4
5
5
4
6
7
1
RXRX+
TXTX+
GND
TXTX+
RXRX+
SG
8PinRJ45 port
RX-
TX-
RX+
TX+
TX-
RX-
TX+
RX+
GND
SG
80
Port 1 / Port 2
8pin RJ45
Female
MT8000 PLC[232]
9P D-SUB Male
COM1
3
TX
3 RXD
RX
2 TXD
5 GND
8 CTS
9 SG
4 RTS
10 SG
5 CTS
7 DSR
8 PHL
14 PV12
HITACHI
9P D-SUB
MICRO-EH port1
8pin RJ45 Male
COM1
COM2
COM3
TX
TX
TX
6 RD
RX
RX
RX
5 SD
GND
GND
GND
1 SG
Port 1
CTS
8 RS
8pin RJ45
Female
4 PHL
7 DR
Driver Version:
Version
Date
V1.10
Oct/22/2009
V1.0
Dec/30/2009
Description of Changes
Fixed HMI occupies the control right of CPU module
81
HUST H4X
HUST CNC Controller H4 Series
http://www.hust.com.tw/
HMI Setting:
Parameters
Recommend
PLC type
HUST H4X
Com port
RS-232
PLC Station
Null
Option
Notes
CPU port
No.
Baud rate
38400
Data bit
Parity bit
Even
Stop bit
Turn delay
9600,19200,38400,57600
Device address:
Bit/Word
Device Type
Format
Range
Memo
1 ~ 99999
DW
VM
ddddd
DW
ddd
0 ~ 255
DW
Cn
ddd
0 ~ 255
DW
Tm
ddd
0 ~ 255
ddd
0 ~ 255
ddd
0 ~ 255
ddd
0 ~ 255
ddd
0 ~ 255
82
only)
B
ddd
VM_bit
ddddd(dd)
0 ~ 255
1 ~ 99999(31)
Wiring diagram:
MT8000 RS-232 / 9P D-SUB
COM1
COM3
RS232 Port
7 TX
8 RX
5 GND
RXD
TXD
GND
3
2
5
COM2
TX
4 TX
RX
6 RX
GND 5 GND
Driver Version:
Version
Date
V1.00
Sep/22/2009
Description of Changes
83
IAI X-SEL
http://www.iai-robot.co.jp/
HMI Setting:
Parameters
Recommend
Option
PLC type
Com port
RS485 4W
Baud rate
9600
9600~19200
Parity bit
Even
Data Bits
7 or 8
Stop Bits
1 or 2
Notes
PLC Setting:
Communication mode
Mode Setting Switch
Parity Check
Sum Check
Device address:
Bit/Word
Device Type
Servo_On_Off
Format
Range
1~8
Memo
Address 1~8 represent the
corresponding axis.
Servo_Origin
1~8
RunProgram
84
EndProgram
SoftWareReset
CurrentAxisPos
1~8
PointMove
1~8
JoggingMove
1~8
AbsoluteMove
1~8
PointChange
1~8
85
Wiring diagram:
MT8000 RS232
9P D-SUB
Host RS232
COM1
COM2
COM3
TX
4 TX
7 TX
RX
RX
6 RX
TX
GND
5 GND
5 GND
RX
GND
86
IDEC
IDEC Micro3, Micro3C, MicroSmart, OpenNet Controller series
http://www.idec.com
HMI Setting:
Parameters
Recommend
Option
PLC type
IDEC Micro
Com port
RS232
RS232, RS485
Baud rate
9600
9600, 19200
Parity bit
Even
Data Bits
7, 8
Stop Bits
Notes
Support Extend address mode
Online Simulator
YES
YES
0-255
PLC Setting:
Communication mode
Device address:
Bit/Word
Device Type
Format
Range
ddd(o)
ddd=0~2047, (o)=0~7
Input(I)
ddd(o)
ddd=0~2047, (o)=0~7
Output(Q)
ddd(o)
ddd=0~2047, (o)=0~7
Internal Relay(M)
RT
ddd
ddd=0~9999
Timer(T)
RC
ddd
ddd=0~9999
Counter(C)
ddd
ddd=0~9999
Data Register(D)
87
Memo
Wiring diagram:
RS232: Micro3C, MicroSmart, OpenNet Controller CPU Ladder Port
CPU port 1 or port2 RS-232
MT8000 RS232
8P mini DIN Male
COM1
COM2
COM3
3 TX 4 TX 7 TX
2 RX 6 RX 8 RX
5 GND 5 GND 5 GND
4 RXD
3 TXD
7 GND
MicroSmart
MT8000
RS232
MT8000
RS485: Micro3 CPU Port, MicroSmart with FC4A-PC2 RS485 Communication Adapter
CPU Port RS-485
MT8000 RS-485
COM1
1 RX2 RX+
5 GND
COM3
6 Data9 Data+
5 GND
2
1
7
RXDRXD+
GND
MT8000 RS-485
9P D-SUB Female
COM1
1 RX2 RX+
5 GND
COM3
6 Data9 Data+
5 GND
A
B
SG
88
RXDRXD+
GND
Driver Version:
Version
Date
V1.20
Jun/19/2009
Description of Changes
89
INOVANCE H2U/H1U
http://www.inovance.cn/
HMI Setting:
Parameters
Recommend
Option
PLC type
INOVANCE H2U/H1U
Com port
RS485 4W
Baud rate
9600
9600~19200
Parity bit
Even
Data Bits
7 or 8
Stop Bits
1 or 2
Notes
PLC Setting:
Communication mode
Mode Setting Switch
Parity Check
Sum Check
Device address:
Bit/Word
Device Type
Format
Range
Memo
ooo
0~377
Input Bits
ooo
0~377
Output Bits
dddd
0~7999
Auxiliary Relay
SM
dddd
8000~9999
ddd
0~255
Timer Relay
ddd
0~255
Counter Relay
TV
ddd
0~255
Timer Memory
CV
ddd
0~199
Counter Memory
DW
CV2
ddd
200~255
dddd
0~7999
Data Registers
SD
dddd
8000~9999
Wiring diagram:
RS-485 4W:
H2U/H1U
RS-422 8P Din
9P D-SUB
1
RX-
TX-
RX+
TX+
TX-
RX-
TX+
RX+
GND
GND
91
Intelligent Servo
Intelligent Servo supports IDM640, IDM240.
http://www.techsoftmotion.com
HMI Setting:
Parameters
PLC type
Com port
Baud rate
Parity bit
Data Bits
Stop Bits
HMI Station No.
PLC Station No.
Recommend
Intelligent Servo
RS232
9600
None
8
1
0
1
Option
Notes
9600~115200
Even, Odd, None
7 or 8
1 or 2
PLC Setting:
Communication mode
Device address:
Bit/Word
W
DW
W
W
Device Type
Register_32bit
Register_H
UDP
STOP
Format
hhh
hhh
hhh
hhh
Range
0~9999
0~9999
hhh:0
hhh:0
Memo
32bit signed
32bit Hex
Send UDP command
Send STOP command
Wiring diagram:
MT8000 RS232
9P D-SUB Female
COM1
3
2
5
COM2
TX
4 TX
RX
6 RX
GND 5 GND
Servo(RS232)
COM3
7 TX
8 RX
5 GND
3
2
5
RD
TD
GND
Driver Version:
Version
Date
Description of Changes
92
V1.00
Nov/06/2009
JUSTFI Controller
Justfi weighing instruments, Industrial Batching Controller supports XK31CB4, XK31CB6.
http://www.justfi.com
HMI Setting:
Parameters
PLC type
Com port
Baud rate
Parity bit
Data Bits
Stop Bits
HMI Station No.
PLC Station No.
Recommend
Justfi controller
RS232
9600
Even
7
1
0
1
Option
Notes
9600, 19200
Even, Odd, None
7 or 8
1 or 2
PLC Setting:
Communication mode
Device address:
Bit/Word
W
DW
W
W
Device Type
Func
Func_DW
RW
RF
Format
dd
dd
hhh
hhh
Range
dd:0~99
dd:0~99
hhh:0
hhh:0
Memo
Read/Write
Read/Write
Weight (Read only)
Read result (Read only)
RT
hhh
hhh:0
RG
hhh
hhh:0
RC
hhh
hhh:0
Circle
RB
hhh
hhh:0
MZ
hhh
hhh:0
MT
hhh
hhh:0
CT
hhh
hhh:0
DT
hhh
hhh:0
BB
hhh
hhh:0
HB
hhh
hhh:0
BD
hhh
hhh:0
WP1t
.
.
hhh
hhh:0
Read/Write Recipe
93
RP6F
Wiring diagram:
MT8000 RS232
9P D-SUB Female
COM1
3
2
5
COM2
TX
4 TX
RX
6 RX
GND 5 GND
CB4(RS232)
COM3
7 TX
8 RX
5 GND
RD
TD
GND
Driver Version:
Version
Date
V1.00
Nov/04/2009
Description of Changes
94
KERNEL SISTEMI
Kernel systemi DMX 30
http://www.kernel.modena.it/
HMI Setting:
Parameters
Recommend
Option
PLC type
Kernel sistemi
Com port
RS232
RS485
Baud rate
19200
9600
Parity bit
Data Bits
Stop Bits
Notes
Device address:
Bit/Word
W
Device Type
Format
hhhh
Range
Memo
0~ffff
Wiring diagram:
MT8000 RS232
9P D-SUB Female
COM1
COM2
COM3
Port2 RS232
9P D-SUB Female
TX
4 TX
7 TX
RX
RX
6 RX
8 RX
TX
5 GND
5 GND
GND
5 GND
Driver Version:
Version
Date
V1.0.0
Feb/04/2010
Description of Changes
95
KEYENCE KV series
KEYENCE KV series, KV10~80
http://www.keyence.com/
HMI Setting:
Parameters
Recommend
Option
PLC type
KEYENCE KV-16
Com port
RS232
Baud rate
9600
Parity bit
Even
Data Bits
Stop Bits
RS232
Notes
PLC Setting:
Communication mode
None
Device address:
Bit/Word
Device Type
Format
Range
RLY
ddd(h)0
0~19999
MR
ddd(h)
0~19999
LR
ddd(h)
0~19999
CR
ddd(h)
0~19999
DM_Bit
ddd(h)
0~19999
DM
ddd
0-1999
TM
ddd
0-99
CM
ddd
0~65535
EM
ddd
0~65535
ddd
0-999
Timer_Curr
ddd
0-999
Timer_Preset
ddd
0-999
ddd
0-999
Counter_Curr
ddd
0-999
Counter_Preset
ddd
0-999
Precaution:
96
Memo
Timer_Current
Counter_Current
If you use the Relay(bit) register, Please place zero behind address.For example, If you want to read Relay(bit)100,
you just set the address as 1000.
Wiring diagram:
RS232: CPU port
MT8000 RS-232 9P D-SUB
COM1
COM2
KEYENCE PLC
COM3
OP-26486
TX
TX
TX
RXD
RX
RX
RX
TXD
GND
GND
GND
GND
Driver Version:
Version
Date
V1.30
Apr/17/2009
Description of Changes
97
KEYENCE KV-1000
http://www.keyence.com/
HMI Setting:
Parameters
Recommend
Option
PLC type
KEYENCE KV-1000
Com port
RS232
Baud rate
9600
Parity bit
Even
Data Bits
Stop Bits
RS232
Notes
PLC Setting:
Communication mode
None
Device address:
Bit/Word
Device Type
Format
Range
RLY
ddd(h)0
0~19999
MR
ddd(h)
0~19999
LR
ddd(h)
0~19999
CR
ddd(h)
0~19999
DM_Bit
ddd(h)
0~19999
DM
ddd
0-1999
TM
ddd
0-99
CM
ddd
0~65535
EM
ddd
0~65535
ddd
0-999
Timer_Curr
ddd
0-999
Timer_Preset
ddd
0-999
ddd
0-999
Counter_Curr
ddd
0-999
Counter_Preset
ddd
0-999
98
Memo
Timer_Current
Counter_Current
Precaution:
If you use the Relay(bit) register, Please place zero behind address.For example, If you want to read Relay(bit)100,
you just set the address as 1000.
Wiring diagram:
RS232: CPU port
MT8000 RS-232 9P D-SUB
COM1
COM2
KEYENCE PLC
COM3
OP-26486
TX
TX
TX
RXD
RX
RX
RX
TXD
GND
GND
GND
GND
Driver Version:
Version
Date
V2.20
Jul/28/2009
Description of Changes
99
HMI Setting:
Parameters
Recommend
Option
Notes
PLC type
Com port
Ethernet
PLC IP
192.168.0.10
TCP port
8501
PLC Setting:
Communication
mode
None
Device address:
Bit/Word
Device Type
Format
Range
Memo
RLY
ddd(h)0
0-19999
MR
ddd(h)
0-19999
LR
ddd(h)
0-19999
CR
ddd(h)
0-19999
DM
ddd
0-1999
TM
ddd
0-99
CM
ddd
0- 65535
EM
ddd
0- 65535
ddd
0-999
Timer_Curr
ddd
0-999
Timer Current
Timer_Preset
ddd
0-999
Timer Preset
ddd
0-999
Counter_Current
ddd
0-999
Counter_Preset
ddd
0-999
Precaution:
If you use the RLY(bit) register, Please place zero behind address.
For example, If you want to read RLY 100, you just set the address as 1000.
100
Wiring diagram:
Ethernet:
MT8000 Ethernet
RJ45
Wire color
TX+
White/Orange
RX+
TX-
Orange
RX-
RX+
White/Green
TX+
BD4+
Blue
BD4+
BD4-
White/Blue
BD4-
RX-
Green
TX-
BD3+
White/Brown
BD3+
BD3-
Brown
BD3-
Wire color
KV-5000 Ethernet
RJ45
TX+
White/Orange
RX+
TX-
Orange
RX-
RX+
White/Green
TX+
BD4+
Blue
BD4+
BD4-
White/Blue
BD4-
RX-
Green
TX-
BD3+
White/Brown
BD3+
BD3-
Brown
BD3-
Driver Version:
Version
Date
V1.00
Dec/25/2009
Description of Changes
101
RJ45
connector
HMI Setting:
Parameters
Recommend
PLC type
COM port
Ethernet
Option
Notes
Modbus protocol
Port No.
502
Device address:
Bit/Word
Device type
Format
Range
3X
ddddd
1~65535
4X
ddddd
1~65535
5X
ddddd
1~65535
6X
ddddd
1~65535
0X
ddddd
1~65535
1X
ddddd
1~65535
3x_Bit
ddddd
1~65535
4x_Bit
ddddd
1~65535
6x_Bit
ddddd
1~65535
102
Memo
Wiring diagram:
Ethernet:
MT8000 Ethernet Wire color
RJ45
Ethernet Hub or
Switch RJ45
1
2
3
TX+
TXRX+
White/Orange
Orange
White/Green
1
2
3
RX+
RXTX+
4
5
6
7
8
BD4+
BD4RXBD3+
BD3-
Blue
White/Blue
Green
White/Brown
Brown
4
5
6
7
8
BD4+
BD4TXBD3+
BD3-
RJ45
RJ45
1
2
3
TX+
TXRX+
White/Orange
Orange
White/Green
3
6
1
RX+
RXTX+
4
5
6
7
8
BD4+
BD4RXBD3+
BD3-
Blue
White/Blue
Green
White/Brown
Brown
4
5
2
7
8
BD4+
BD4TXBD3+
BD3-
Driver Version:
Version
Date
V1.61
Apr/17/2009
Description of Changes
103
8
RJ45
HMI Setting:
Parameters
Recommend
Option
Notes
PLC type
CLICK
Com port
RS232
Baud rate
38400
Parity bit
Odd
Data Bits
Stop Bits
Device address:
Bit/Word
Device Type
Format
Range
d(dd)
001 ~ 816
d(dd)
001 ~ 816
Output Status
dddd
1 ~ 2000
Control Bit
ddd
1 ~ 500
CT
ddd
1 ~ 250
SC
dddd
1 ~ 1000
DS
dddd
1 ~ 4500
Data Registers
DD
dddd
1 ~ 1000
DH
dddd
1 ~ 500
Data Registers
DF
dddd
1 ~ 500
XD
0~8
YD
0~8
TD
ddd
1 ~ 500
CTD
ddd
1 ~ 250
SD
dddd
1 ~ 1000
TXT
dddd
1 ~ 1000
104
Memo
Wiring diagram:
KOYO CLICK PLC Com Port:
9P D-SUB
COM1[RS232]
COM2[RS232]
COM3[RS232]
TX
TX
TX
RXD
RX
RX
RX
TXD
GND
GND
GND
GND
Driver Version:
Version
Date
V1.20
Oct/20/2009
V1.10
Apr/17/2009
Description of Changes
Fixed the bit addresses X, Y and word addresses XD, YD are not
able to read/write correctly.
105
KOYO DirectLogic
KOYO DirectLogic series PLC DL05, DL06DL105, DL205, DL305 and DL405 series
http://www.automationdirect.com
HMI Setting:
Parameters
Recommend
Option
PLC type
KOYO DIRECT
Com port
RS232
RS232, RS485
Baud rate
9600
Parity bit
Odd
Data Bits
7, 8
Stop Bits
Notes
1-90
PLC Setting:
1.
2.
3.
4.
5.
6.
When using the D4-440 CPU, you must set the station number to 1.
Device address:
Bit/Word
Device Type
Format
Range
oooo
0 ~ 4000
Input Bits
oooo
0 ~ 4000
Output Bits
ooooo
0 ~ 10000
Control Relays
oooo
0 ~ 1000
CT
oooo
0 ~ 1000
oooo
0 ~ 2000
SP
oooo
0 ~ 2000
GX
ooooo
0 ~ 10000
106
Memo
GY
ooooo
0 ~ 10000
Timer
oooo
0 ~ 1000
Counter
oooo
0 ~ 1000
oooo
0 ~ 77777
V Memory
Wiring diagram:
1. CPU unit: DL05/DL06/DL105/DL230/DL240/DL250/DL350/DL450 RS232 port
MT8000 RS232
9P D-SUB
COM1
COM2
3 TX
4 TX
2 RX
6 RX
5 GND 5 GND
COM3
7 TX
8 RX
5 GND
3 RX
4 TX
1 GND
RJ12 6Pin
Female
9P D-SUB
COM1
COM2
COM3
3 TX
2 RX
5 GND
4 TX
6 RX
5 GND
7 TX
8 RX
5 GND
3
2
7
4
5
RX
TX
GND
RTC
CTS
COM1 [RS-485] 4w
9P D-SUB
1
2
5
3
4
RXRX+
GND
TXTX+
10
9
7
6
13
11
14
12
15
Note: DL06/DL250 CPU Port2 include RS232 and RS422
107
TXTX+
GND
RXRX+
RTS+
CTS+
RTSCTS-
108
9P D-SUB
COM1
COM2
COM3
3 TX
2 RX
5 GND
4 TX
6 RX
5 GND
7 TX
8 RX
5 GND
3
RX
2
TX
13 GND
1
YOP
7
CTS
2
YOM
4
ONLINE
14 GND
5. CPU unit: DL430/DL440/DL450 CPU unit Port1 & DL350 CPU unit Port2 RS232
MT8000 RS232
9P D-SUB
COM1
COM2
COM3
3 TX
2 RX
5 GND
4 TX
6 RX
5 GND
7 TX
8 RX
5 GND
3
2
7
4
5
RX
TX
GND
RTC
CTS
6. CPU unit: DL430/DL440/DL450 CPU unit Port1 & DL350 CPU unit Port2 RS422
MT8000
COM1[RS-485]4w
9P D-SUB
1
2
5
3
4
16
14
7
10
9
19
11
18
23
RXRX+
GND
TXTX+
109
TXTX+
GND
RXRX+
RTS+
CTS+
RTSCTS-
COM1[RS-485]4w
9P D-SUB
1
2
5
3
13
TX12
TX+
7
GND
25
RX24 RX+
RXRX+
GND
TX4 TX+
8. Communication unit: DL205 series D2-DCM and DL405 series D4-DCM RS232
KOYO DirectLogic PLC
MT8000 RS232
DL205/405 DCM RS232 Port
9P D-SUB
25P D-SUB Female
COM1
COM2
COM3
3 TX
2 RX
5 GND
4 TX
6 RX
5 GND
7 TX
8 RX
5 GND
3
2
7
4
5
RX
TX
GND
RTC
CTS
Driver Version:
Version
Date
V1.20
Dec/30/2008
Description of Changes
110
HMI Setting:
Parameters
Recommend
PLC type
KOYO ETHERNET
Com port
Ethernet, UDP/IP
TCP/IP port
28784
Option
Notes
Device address:
Bit/Word
Device Type
Format
Range
Memo
GX
oooo
0~3777
Global I/O
oooo
0~1777
SP
oooo
0~1777
GY
oooo
0-3777
oooo
0-1777
oooo
0-3777
Control Relays
ooo
0-1777
ooo
0-377
CT
ooo
0-377
ooooo
0-41237
V-memory
CMM_32
hhh
001-200
GX, X, SP
CCM_33
hhh
001-340
GY,Y,C,S,Y,CT,V
CCM_31
hhhh
1-42A0
EB8000 device addresses range may different with PLC extended mode, please refer EB8000s
addresses range as above.
ddd:Decimal, hhh:Hexadecimal, ooo:Octal
111
Wiring diagram:
Ethernet port
MT8000 Ethernet Wire color
RJ45
Ethernet Hub or
Switch RJ45
1
2
3
TX+
TXRX+
White/Orange
Orange
White/Green
1
2
3
RX+
RXTX+
4
5
6
7
8
BD4+
BD4RXBD3+
BD3-
Blue
White/Blue
Green
White/Brown
Brown
4
5
6
7
8
BD4+
BD4TXBD3+
BD3-
RJ45
RJ45
1
2
3
TX+
TXRX+
White/Orange
Orange
White/Green
3
6
1
RX+
RXTX+
4
5
6
7
8
BD4+
BD4RXBD3+
BD3-
Blue
White/Blue
Green
White/Brown
Brown
4
5
2
7
8
BD4+
BD4TXBD3+
BD3-
Driver Version:
Version
Date
V1.10
Jul/03/2009
Description of Changes
112
Lenze
PLC Model No. : 9300/8200 series
Pass-through 2102IB fieldbus module:RS485(LECOM B)
http://www.lenze.de
HMI Setting:
Parameters
Recommend
Option
Notes
PLC type
Lenze
Com port
RS485
RS485
Baud rate
9600
9600, 19200
Parity bit
Even
Data Bits
7,8
Stop Bits
1, 2
0-255
0-255
PLC Setting:
Communication mode
Device address:
Bit/Word
Device Type
Format
Range
B
W
W
W
W
W
W
CNB
CI
CD
CF
CNI
CND
CNF
ddd(dd)
ddd
ddd
ddd
0-999915
0-819200
0-819200
0-819200
0-9999
0-9999
0-9999
ddd
ddd
ddd
Memo
integer
DWord
DWord(float point)
Wiring diagram:
EasyView MT8000 HMI
COM1
COM3
1
2
6
9
RXRX+
DataData+
72
71
113
T/R(A)
T/R(B)
Driver Version:
Version
Date
V1.10
Apr/17/2009
Description of Changes
114
LS GLOFA Cnet
LS GLOFA GM6/GM7 CPU port. G7L-CUEB / G6L-CUEB / G4L-CUEA / G3L-CUEA Cnet
module.
http://www.lgis.com/
HMI Setting:
Parameters
Recommend
Option
Notes
PLC type
LS GLOFA Cnet
Com port
RS232
RS232/RS485 2W/4W
Baud rate
9600
9600~115200
Parity bit
None
Data Bits
7, 8
Stop Bits
0~31
PLC Setting:
Communication mode
Communication module
Device address:
Bit/Word
Device Type
Format
Range
Memo
IX
hhhh(dd)
0~270F15
Input
QX
hhhh(dd)
0~270F15
Output
MX
ddddd
0~32767
Internal relay
MW
ddddd
0~32767
Data register
DW
MD
ddddd
0~16383
Double word
d:(Decimal)
h:(Hexadecimal)
Wiring diagram:
RS-232:
MT8000 RS232
9P D-SUB
LG GLOFA GM
CPU port
RS232 9P D-SUB
COM1
COM2
COM3
TX
4 TX
7 TX
RXD
RX
6 RX
TXD
GND
5 GND
5 GND
GND
RX
115
LG GLOFA GM
RS232 9P D-SUB
COM1
COM2
COM3
TX
4 TX
7 TX
RXD
RX
6 RX
TXD
GND
5 GND
5 GND
GND
CD
RTS
CTS
DTR
DSR
RX
MT8000
COM1[RS-485]4w
9P D-SUB
1
RX-
SDA
RX+
SDB
TX-
RDA
TX+
RDB
GND
GND
Driver Version:
Version
Date
V1.60
Apr/16/2009
Description of Changes
116
HMI Setting:
Parameters
Recommend
PLC type
LS GLOFA GM3467(LOADER)
Com port
RS-232
Option
Notes
38400
Data bit
Parity bit
Stop bit
Device address:
Bit/Word
Device Type
Format
Range
MX
ddddd
IX
dd.D.dd
00000~63763
QX
dd.D.dd
00000~63763
MW
dddd
0~32767
MD
ddddd
0~16383
Memo
0~524272
00.0.0 ~63.7.63
(dd.D.dd)
00.0.0 ~63.7.63
(dd.D.dd)
Wiring diagram:
RS-232:
LS GLOFA series
RS-232
9P D-SUB Female
MT8000 RS232
9P D-SUB Female
COM1
COM2
COM3
TX
TX
TX
RD
RX
RX
RX
TD
GND
GND
GND
GND
117
Driver Version:
Version
Date
V1.20
Feb/11/2010
Description of Changes
Modify the addressing
118
LS MASTER-K Cnet
LS MASTER-K series: K80S, K200S, K300S, K1000S
http://www.lgis.com/
HMI Setting:
Parameters
Recommend
PLC type
LS MASTER-K Cnet
Com port
RS232
RS232/RS485
Baud rate
38400
Parity bit
None
Data Bits
Stop Bits
Online Simulator
Option
Notes
0-31
YES
PLC Setting:
Communication mode
38400, None, 8, 1
Device address:
Bit/Word
Device
Type
Format
Range
Memo
ddd(h)
0~255F
ddd(h)
0~255F
ddd(h)
0~255F
ddd(h)
0~255F
ddd(h)
0~255F
TV
ddd
0~255
CV
ddd
0~255
dddd
0~9999
d: Decimal h: Hexadecimal
119
Wiring diagram:
COM1
MT8000 RS232
9P D-SUB
RS232
9P D-SUB Female
COM2
COM3
4 RX
3 TX 4 TX 7 TX
7 TX
2 RX 6 RX 8 RX
5 GND
5 GND 5 GND 5 GND
If connect with Cnet module please refer Cnet modules document.
Driver Version:
Version
Date
V1.00
Dec/30/2008
Description of Changes
120
LS MASTER-K10S1
LS MASTER-K10S1
http://www.lgis.com/
HMI Setting:
Parameters
Recommend
Option
Notes
PLC type
LS MASTER-K10S1
Com port
RS232
RS232/RS485
Baud rate
9600
Parity bit
None
None
Data Bits
Stop Bits
PLC Setting:
Communication
mode
9600, None, 8, 1
Select
Device address:
Bit/Word
Device
Type
Format
Range
Memo
ddd(h)
0~255F
ddd(h)
0~255F
ddd(h)
0~255F
ddd(h)
0~255F
ddd(h)
0~255F
ddd
0~255
Timer (T)
ddd
0~255
Counter (C)
TV
ddd
0~255
CV
ddd
0~255
dddd
0~9999
d: Decimal h: Hexadecimal
Wiring diagram:
MT8000 RS232
9P D-SUB
9P D-SUB Female
COM1
3 TX
2 RX
5 GND
COM2
4 TX
6 RX
5 GND
COM3
7 TX
8 RX
5 GND
RX
TX
GND
Driver Version:
Version
Date
V1.00
Sep/08/2009
Description of Changes
122
LS MASTER-K300S CPU
LS MASTER-K series: K80S, K120S, K200S, K300S, K1000S
http://www.lgis.com/
HMI Setting:
Parameters
Recommend
PLC type
LG MASTER-K300S
Com port
RS232
RS232/RS485
Baud rate
38400
Parity bit
None
Data Bits
Stop Bits
Online Simulator
Option
Notes
0-31
YES
PLC Setting:
Communication
38400, None, 8, 1
mode
Device address:
Bit/Word
Device
Type
Format
Range
ddd(h)
0~255F
ddd(h)
0~255F
ddd(h)
0~255F
ddd(h)
0~255F
ddd(h)
0~255F
TV
ddd
0~255
CV
ddd
0~255
dddd
0~9999
123
Memo
d: Decimal h: Hexadecimal
Wiring diagram:
COM1
MT8000 RS232
9P D-SUB
9P D-SUB Female
COM2
3 TX
4 TX
2 RX
6 RX
5 GND 5 GND
COM3
7 TX
8 RX
5 GND
2 RX
3 TX
5 GND
Driver Version:
Version
Date
V1.10
Dec/30/2008
Description of Changes
124
LS XGB/XGT
LS XGB/XGT Series
http://www.lgis.com/
HMI Setting:
Parameters
Recommend
Option
Notes
PLC type
LS XGB/XGT
Com port
RS232
RS232/RS485
Baud rate
115200
9600~115200
Parity bit
None
Data Bits
7, 8
Stop Bits
0-31
Device address:
Bit/Word
Device Type
Format
Range
ddd(h)
0~127F
ddd(h)
0~255F
dddd(h)
0~1279F
dddd(h)
0~2559F
ddd(h)
0~255F
ddd
0~255
ddd
0~255
ddd(dd)
0~127(99)
D_Bit
dddd(h)
0~5120F
dh:0~3f
XGK-CPUE:hh(0~1f)
U_Bit
dh.dd(h)
Memo
dd:0~31
(h):0~f
dddd
0~5119
d(dd)
0~7(0~31)
dddd
0~3935
ddd
0~127
ddd
0~255
125
d:Decimal
ddd
0~255
h:Hexadecimal
Wiring diagram:
RS-232:
6pin female pinout
MT8000 RS232
9P D-SUB
COM1
3
2
5
COM2
TX
4 TX
RX
6 RX
GND 5 GND
COM3
7 TX
8 RX
5 GND
RXD
TXD
GND
Driver Version:
Version
Date
V1.30
Apr/17/2009
Description of Changes
126
HMI Setting:
Parameters
Recommend
PLC type
LS XBB/XGT FEnet
Com port
Ethernet
TCP/IP port
2004
Option
Notes
0~255
PLC Setting:
Communication mode
FEnet Potocol
Device address:
Bit/Word
Device Type
Format
Range
Memo
ddd(h)
0~127F
ddd(h)
0~255F
dddd(h)
0~1279F
dddd(h)
0~2559F
ddd(h)
0~255F
ddd
0~255
ddd
0~255
ddd(dd)
0~127(99)
D_Bit
dddd(h)
0~5120F
dh:0~3f
B
U_Bit
dh.dd(h)
dd:0~31
(h):0~f
dddd
0~5119
d(dd)
0~7(0~31)
dddd
0~3935
ddd
0~127
ddd
0~255
127
d:(Decimal)
ddd
0~255
h:(Hexadecimal)
Wiring diagram:
Ethernet:
MT8000 Ethernet
Wire color
RJ45
RJ45
TX+
White/Orange
RX+
TX-
Orange
RX-
RX+
White/Green
TX+
BD4+
Blue
BD4+
BD4-
White/Blue
BD4-
RX-
Green
TX-
BD3+
White/Brown
BD3+
BD3-
Brown
BD3-
MT8000
TCP Device
Ethernet RJ45
RJ45
TX+
White/Orange
RX+
TX-
Orange
RX-
RX+
White/Green
TX+
BD4+
Blue
BD4+
BD4-
White/Blue
BD4-
RX-
Green
TX-
BD3+
White/Brown
BD3+
BD3-
Brown
BD3-
Driver Version:
Version
Date
V1.20
Apr/17/2009
Description of Changes
128
8
RJ45
LS XGL-CH2A Cnet
LS XGT series communication module XGL-CH2A
http://www.lgis.com/
HMI Setting:
Parameters
Recommend
Option
PLC type
LS XGL-CH2A Cnet
Com port
RS232
RS232/RS485 2W/4W
Baud rate
19200
9600~115200
Parity bit
None
Data Bits
7, 8
Stop Bits
Notes
PLC Setting:
Communication mode
Device address:
Bit/Word
Device Type
Format
Range
Memo
dddd(h)
0~2047F
I/O device
dddd(h)
0~2047F
Internal device
dddd(h)
0~2047F
Communication device
dddd(h)
0~2047F
Preservation device
dddd(h)
0~2047F
dddd
0~2047
Timer device
dddd
0~2047
Counter device
ddd(dd)
0~127(99)
D_Bit
dddd(h)
U_Bit
dh.dd(h)
0~19999F
hh:0~3f, dd:0~31
(h):0~f
dddd
0~19999
Data register
hh(dd)
0~3f(0~31)
dddd
0~21503
ddd
0~127
dddd
0~2047
dddd
0~2047
ddddd
0~32767
ZR
ddddd
0~32767
129
XGK-CPUE : hh(0~1f)
Bit/Word
Device Type
Format
Range
Memo
TS
dddd
0~2047
Setup value
CS
dddd
0~2047
Setup value
d:(Decimal)
h:(Hexadecimal)
Wiring diagram:
RS-232:
MT8000 RS232
9P D-SUB
XGL-CH2A
CH1
RS232 9P D-SUB
COM1
COM2
COM3
TX
4 TX
7 TX
RXD
RX
6 RX
TXD
GND
5 GND
GND
GND
RX
RS485 4wire:
XGL-CH2A
MT8000
CH2
COM1[RS-485]4w
5P terminal.
9P D-SUB
1
RX-
TX-
RX+
TX+
TX-
RX-
TX+
RX+
GND
GND
Driver Version:
Version
Date
V1.20
Nov/30/2009
Description of Changes
130
HMI Setting:
Parameters
Recommend
Option
PLC type
Com port
Ethernet
Port no.
2004
Notes
PLC Setting:
Communication mode
Device address:
Bit/Word
Device Type
Format
Range
Memo
dddd(h)
0~2047F
I/O device
dddd(h)
0~2047F
Internal device
dddd(h)
0~2047F
Communication device
dddd(h)
0~2047F
Preservation device
dddd(h)
0~2047F
dddd
0~2047
Timer device
dddd
0~2047
Counter device
ddd(dd)
0~127(99)
D_BIT
dddd(h)
U_BIT
dh.dd(h)
dddd
0~32767F
dh:0~3f, dd:0~31
(h):0~f
0~19999
hh(dd)
0~3f(0~31)
dddd
0~21503
ddd
0~127
dddd
0~2047
131
XGK-CPUE : hh(0~1f)
Data register
Bit/Word
Device Type
Format
Range
Memo
dddd
0~2047
ddddd
0~32767
ZR
ddddd
0~32767
d:(Decimal)
h:(Hexadecimal)
Wiring diagram:
Ethernet:
MT8000 Ethernet Wire color
RJ45
1
TX+
White/Orange
Ethernet Hub or
Switch RJ45
RX+
1
TX-
Orange
RX+
White/Green
TX+
BD4+
Blue
BD4+
BD4-
White/Blue
BD4-
RX-
Green
TX-
BD3+
White/Brown
BD3+
BD3-
Brown
BD3-
RXRJ45
XGL-EFMT
RJ45
TX+
White/Orange
RX+
TX-
Orange
RX-
RX+
White/Green
TX+
BD4+
Blue
BD4+
BD4-
White/Blue
BD4-
RX-
Green
TX-
132
BD3+
White/Brown
BD3+
BD3-
Brown
BD3-
Driver Version:
Version
Date
V1.20
Nov/30/2009
Description of Changes
133
HMI Setting:
Parameters
Recommend
Option
PLC type
Com port
RS232
RS232/RS485
Baud rate
19200
9600~115200
Parity bit
None
Data Bits
7, 8
Stop Bits
Notes
PLC Setting:
Communication mode
Device address:
Bit/Word
Device Type
Format
Range
Memo
dddd(h)
0~2047F
I/O device
dddd(h)
0~2047F
Internal device
dddd(h)
0~2047F
Communication device
dddd(h)
0~2047F
Preservation device
dddd(h)
0~2047F
dddd
0~2047
Timer device
dddd
0~2047
Counter device
ddd(dd)
0~127(99)
D_Bit
dddd(h)
U_Bit
hhdd(h)
0~19999F
hh:0~3f, dd:0~31
(h):0~f
dddd
0~19999
Data register
hh(dd)
0~3f(0~31)
dddd
0~21503
ddd
0~127
dddd
0~2047
dddd
0~2047
ddddd
0~32767
134
XGK-CPUE : hh(0~1f)
ZR
ddddd
0~32767
TS
dddd
0~2047
Setup value
CS
dddd
0~2047
Setup value
d:(Decimal)
h:(Hexadecimal)
Wiring diagram:
RS-232:
MT8000 RS232
9P D-SUB
COM1
COM2
COM3
TX
TX
TX
RXD
RX
RX
RX
TXD
GND
GND
GND
GND
Driver Version:
Version
Date
V1.00
Nov/30/2009
Description of Changes
135
LIYAN EX series
LIYAN PLC Ex/Ex1s/Ex1n/Ex2n series
http://www.liyanplc.com/
HMI Setting:
Parameters
PLC type
Com port
Baud rate
Parity bit
Data Bits
Stop Bits
HMI Station No.
PLC Station No.
Recommend
Mitsubishi FX0n/FX2
RS232
9600
Even
7
1
0
0
Option
RS232
9600~115200
Even, Odd, None
7,8
1,2
0-255
0-255
Notes
Must match the PLCs port setting.
Must match the PLCs port setting.
Must match the PLCs port setting.
Must match the PLCs port setting.
Must match the PLCs port setting.
Does not apply to this protocol.
Must match the PLCs port setting.
PLC Setting:
Communication mode
9600,7,1,Even
Device address:
Bit/Word
B
B
B
B
B
W
W
W
W
W
Device
Type
X
Y
M
T
C
TV
CV
D
CV2
SD
Format
Range
ooo
ooo
ddd
ddd
ddd
ddd
ddd
ddd
ddd
ddd
0-377
0-377
0-9999
0-255
0-255
0-255
0~199
0-9999
200-255
8000-9999
136
Memo
Input relay
Output relay
Internal bit memory
Timer bit memory
Counter bit memory
Timer register
Counter Register
data Register
Counter Register(Double word)
Special data register
Wiring diagram:
Ex,Ex1s,Ex1n,Ex2n series RS232
LIYAN Ex series
CPU RS232 Port
8P miniDin Female
MT8000 RS232
9P D-SUB
COM1
COM2
COM3
TX
4 TX
7 TX
RXD
RX
6 RX
8 RX
TXD
5 GND
5 GND
GND
5 GND
Driver Version:
Version
Date
V1.10
Aug/12/2009
Description of Changes
137
8Pin miniDin
Female
HMI Setting:
Parameters
Recommend
PLC type
Master (Master-Slave
Option
Notes
Protocol)
Com port
RS232
Baud rate
115200
Parity bit
Even
Data Bits
Stop Bits
Parameter 1
MT500 PLC ID
38400, 115200
PLC Setting:
Communication mode
138
Device address:
Bit/Word
MT500
MT8000
Range
Ms_RB
RW_Bit
Ms_LB
LB
dddd:0~9999
Ms_RW
RW
ddd:0~65535
Ms_LW
LW
ddd:0~9999
ddd:0~4095
139
Memo
(h): 0~f
Driver Version:
Version
Date
V1.00
Dec/30/2008
Description of Changes
140
http://www.yaskawa.com/
HMI Setting:
Parameters
Recommend
Option
Notes
PLC type
Memobus
Com port
RS485/Ethernet
Baud rate
19200
9600~57600
Parity bit
Even
Data Bits
Stop Bits
1-31
502
default
PLC Setting:
Communication mode
Select
Device address:
Bit/Word
B
Device Type
Format
Range
MB_1
ddddh
dddd:0~9999,
Memo
MB 0~9999
h: 0~f
MB_2
ddddh
dddd:10000~65535,
MB 10000~65535
h: 0~f
IB
hhhh
hhhh : 0~A7FF
Read only
IW
hhhh
hhhh : 0~A7FF(8FFF)*
Read only
DW
IL
hhhh
hhhh : 0~A7FE(8FFE)*
Read only
IF
hhhh
hhhh : 0~A7FE(8FFE)*
Read only
MW
ddddd
ddddd:0~65534
Holding Register
Double word
Floating point
DW
ML
ddddd
ddddd:0~65533
MF
ddddd
ddddd:0~65533
*: When connect via Ethernet interface the max range of IW, IL and IF would be restricted.
141
Wiring diagram:
1. RS-232: 217IF-01, 218IF-01
217IF-01 RS232
9P D-SUB Female
MT8000 RS232
COM1
COM2
COM3
TX
TX
TX
RX
RX
RX
RX
TX
GND
GND
GND
7 GND
217IF-01 RS422/485
14P connector
COM3
RX-
Data-
2, 4
D-
RX+
Data+
1, 3
D+
GND
GND
14
217IF-01 RS422/485
COM1
14P connector
RX-
2 TX-
RX+
1 TX+
TX-
4 RX-
TX+
3 RX+
GND
14 GND
4. Ethernet:
MT8000
Wire color
Ethernet Hub or
Ethernet RJ45
1
2
3
4
5
6
7
8
Switch RJ45
TX+
White/Orange
RX+
TX-
Orange
RX-
RX+
White/Green
TX+
BD4+
Blue
BD4+
BD4-
White/Blue
BD4-
RX-
Green
TX-
BD3+
White/Brown
BD3+
BD3-
Brown
BD3-
142
GND
Wire color
TX+
White/Orange
RX+
TX-
Orange
RX-
RX+
White/Green
TX+
BD4+
Blue
BD4+
BD4-
White/Blue
BD4-
RX-
Green
TX-
BD3+
White/Brown
BD3+
BD3-
Brown
BD3-
Ethernet RJ45
1
2
3
4
5
6
7
8
143
Driver Version:
Version
Date
V1.40
Apr/21/2009
Description of Changes
144
HMI Setting:
Parameters
Recommend
Option
Notes
PLC type
Memory Map
Com port
RS232
Baud rate
115200
9600~115200
Parity bit
Even
Data Bits
Stop Bits
RS232 default
Device address:
Bit/Word
B
W
Device Type
MB
MW
Format
ddd(h)
ddd
Range
ddd:0~9999 (h): 0~F
ddd:0~9999
Wiring diagram:
RS-232:
MT8000 RS232
9P D-SUB
MT8000 RS232
9P D-SUB
2 RX
3 TX
5 GND
3 TX
2 RX
5 GND
RS-485 2W:
MT8000 RS485
9P D-SUB
MT8000 RS485
9P D-SUB
1 RX2 RX+
5 GND
1 RX2 RX+
5 GND
145
Memo
RS-485 4W:
MT8000 RS485
9P D-SUB
1
2
3
4
5
MT8000 RS485
9P D-SUB
RX-
3 TX-
RX+
4 TX+
TX-
1 RX-
TX+
2 RX+
GND
5 GND
NOTE :
For Memory map information, please refer user manual [chapter 31 Memory Map
communication].
Driver Version:
Version
Date
V1.00
Mar/19/2009
Description of Changes
146
MITSUBISHI A1S
MITSUBISHI A1S
http://www.mitsubishi-automation.com/
HMI Setting:
Parameters
Recommend
PLC type
MITSUBISHI A1S
Com port
RS232
Baud rate
9600
Parity bit
Odd
Data Bits
Stop Bits
Option
Notes
PLC Setting:
Communication
mode
9600, Odd, 8, 1
Device address:
Bit/Word
Device
Type
Format
hhhh
0-ffff
Input Relay
hhhh
0-ffff
Output Relay
ddddd
0-65535
Auxiliary Relay
hhhh
0-ffff
ddddd
0-65535
TV
ddddd
0-65535
Timer Memory
CV
ddddd
0-65535
Counter Memory
ddddd
0-65535
Data Register
hhhh
0-ffff
ddddd
0-65535
Range
d: Decimal h: Hexadecimal
147
Memo
Wiring diagram:
Use the RS422 to RS232 PLC programming cable (show as follows)
Mitsubishi
PLC
MT8000
programming
RS-422
COM1 RS232
Cable
9P D-SUB Female
DB25 Male
2
RX+
RD
TD
TX+
TD
RD
DSR+
GND
GND
GND
RTS
CTS
15
RX-
CTS
RTS
16
TX-
17
DSR148
Driver Version:
Version
Date
V1.00
Sep/18/2009
Description of Changes
149
MITSUBISHI A2A
MITSUBISHI A2A
http://www.mitsubishi-automation.com/
HMI Setting:
Parameters
Recommend
PLC type
MITSUBISHI A2A
Com port
RS232
Baud rate
9600
Parity bit
Odd
Data Bits
Stop Bits
Option
Notes
PLC Setting:
Communication
mode
9600, Odd, 8, 1
Device address:
Bit/Word
Device
Type
Format
hhhh
0-270f
Input Relay
hhhh
0-270f
Output Relay
dddd
0-9999
Auxiliary Relay
hhhh
0-ffff
ddddd
0-65535
TV
ddd
0-255
Timer Memory
CV
ddd
0-255
Counter Memory
dddd
0-9999
Data Register
hhhh
0-ffff
ddddd
0-65535
Range
d: Decimal h: Hexadecimal
150
Memo
Wiring diagram:
Use the RS422 to RS232 PLC programming cable (show as follows)
Mitsubishi
PLC
MT8000
programming
RS-422
COM1 RS232
Cable
9P D-SUB Female
DB25 Male
2
RX+
RD
TD
TX+
TD
RD
DSR+
GND
GND
GND
RTS
CTS
15
RX-
CTS
RTS
16
TX-
17
DSR-
151
Driver Version:
Version
Date
V1.00
Aug/12/2009
Description of Changes
152
MITSUBISHI A2US
MITSUBISHI A2US
http://www.mitsubishi-automation.com/
HMI Setting:
Parameters
Recommend
Option
PLC type
MITSUBISHI A2US
Com port
RS232
Baud rate
9600
Parity bit
Odd
Data Bits
Stop Bits
Notes
PLC Setting:
Communication
mode
9600, Odd, 8, 1
Device address:
Bit/Word
Device
Type
Format
hhhh
0-270f
Input Relay
hhhh
0-270f
Output Relay
dddd
0-9999
Auxiliary Relay
TV
ddd
0-255
Timer Memory
CV
ddd
0-255
Counter Memory
dddd
0~9999
Data Register
Range
Memo
d: Decimal h: Hexadecimal
Wiring diagram:
Use the RS422 to RS232 PLC programming cable (show as follows)
153
PLC
Mitsubishi
MT8000
programming
RS-422
COM1 RS232
Cable
9P D-SUB Female
DB25 Male
2
RX+
RD
TD
TX+
TD
RD
DSR+
GND
GND
GND
RTS
CTS
15
RX-
CTS
RTS
16
TX-
17
DSR-
Driver Version:
Version
Date
V1.00
Mar/20/2009
Description of Changes
154
MITSUBISHI A3N/A1SH
MITSUBISHI A3N/A3A/A1SH/A2SH
http://www.mitsubishi-automation.com/
HMI Setting:
Parameters
Recommend
Option
PLC type
MITSUBISHI A3N/A1SH
Com port
RS232
Baud rate
9600
Parity bit
Odd
Data Bits
Stop Bits
Notes
PLC Setting:
Communication
mode
9600, Odd, 8, 1
Device address:
Bit/Word
Device
Type
Format
hhhh
0-ffff
Input Relay
hhhh
0-ffff
Output Relay
ddddd
0-65535
Auxiliary Relay
hhhh
0-ffff
ddddd
0-65535
TV
ddddd
0-65535
Timer Memory
CV
ddddd
0-65535
Counter Memory
ddddd
0-65535
Data Register
hhhh
0-ffff
ddddd
0-65535
Range
d: Decimal h: Hexadecimal
155
Memo
Wiring diagram:
Use the RS422 to RS232 PLC programming cable (show as follows)
Mitsubishi
PLC
MT8000
programming
RS-422
COM1 RS232
Cable
9P D-SUB Female
DB25 Male
2
RX+
RD
TD
TX+
TD
RD
DSR+
GND
GND
GND
RTS
CTS
15
RX-
CTS
RTS
16
TX-
17
DSR-
Driver Version:
156
Version
Date
V1.00
Oct/20/2009
Description of Changes
157
MITSUBISHI AJ71
Mitsubishi A series PLC with AJ71C24 communication module using the Computer Link protocol.
http://www.mitsubishi-automation.com
HMI Setting:
Parameters
Recommend
Option
Notes
PLC type
MITSUBISHI AJ71
Com port
RS485 4W
Baud rate
19200
9600, 19200
Parity bit
Even
Data Bits
Stop Bits
PLC Setting:
Communication mode
Format 1
Parity Check
Enable
Sum Check
Enable
Device address:
Bit/Word
B
Device Type
Format
Range
hhh
hhh: 0~270F
Memo
Input Bits
(hex-decimal)
Y
hhh
hhh: 0~270F
Output Bits
(hex-decimal)
dddd
dddd:0~9999
TV
ddd
ddd:0~255
CV
ddd
ddd:0~255
dddd
ddd:0~9999
Data Registers
158
Internal Relays
Wiring diagram:
RS-485 4W:
AJ71C24
RS-422
9P D-SUB
1
RX-
SDB
RX+
SDA
TX-
RDB
TX+
RDA
GND
GND
RS-232: A1SJ71UC24-R2
RS232 port
9P D-SUB Female
MT8000 RS232
9P D-SUB
COM1
COM2
COM3
TX
TX
TX
RXD
RX
RX
RX
TXD
GND
GND
DCD
DTR
DSR
RTS
CTS
GND
GND
Driver Version:
Version
Date
V1.40
Feb/09/2009
Description of Changes
159
HMI Setting:
Parameters
Recommend
PLC type
MITSUBISHI MELSEC-Q
Com port
Ethernet
Parameter1
Option
Notes
0~255
0~255
as PLC setting)
TCP/IP port
Device address:
Bit/Word
Device Type
Format
Range
SM
dddd
0 ~ 2047
Special Relay
hhhh
0 ~ 1FFF
Input Relay
hhhh
0 ~ 1FFF
Output Relay
dddd
0 ~ 8191
Internal Relay
dddd
0 ~ 8191
Latch Relay
dddd
0 ~ 2047
Annunciator
dddd
0 ~ 2047
Edge Relay
hhhh
0 ~ 1FFF
Link Relay
TS
dddd
0 ~ 2047
Timer Contact
TC
dddd
0 ~ 2047
Timer Coil
SS
dddd
0 ~ 2047
SC
dddd
0 ~ 2047
CS
dddd
0 ~ 1023
Counter Contact
CC
dddd
0 ~ 1023
Counter Coil
SB
hhh
0 ~ 7FF
dddd
0 ~ 8191
Step relay
DX
hhhh
0 ~ 1FFF
Direct Input
DY
hhhh
0 ~ 1FFF
Direct Output
SD
dddd
0 ~ 2047
Special register
160
Memo
ddddd
0 ~ 12287
Data Register
hhhh
0 ~ 1FFF
Link Register
TN
dddd
0 ~ 2047
SN
dddd
0 ~ 2047
CN
dddd
0 ~ 1023
SW
hhh
0 ~ 7FF
dd
0 ~ 15
Index Register
ddddd
0 ~ 32767
File Register
ZR
hhhhh
0 ~ FE7FF
File Register
Wiring diagram:
Ethernet:
MT8000 Ethernet Wire color
Ethernet Hub or
RJ45
Switch RJ45
1
2
3
4
5
6
7
8
TX+
TXRX+
BD4+
BD4RXBD3+
BD3-
White/Orange
Orange
White/Green
Blue
White/Blue
Green
White/Brown
Brown
1
2
3
4
5
6
7
8
RX+
RXTX+
BD4+
BD4TXBD3+
BD3-
RJ45
1
2
3
TX+
TXRX+
White/Orange
Orange
White/Green
3
6
1
RX+
RXTX+
4
5
6
7
8
BD4+
BD4RXBD3+
BD3-
Blue
White/Blue
Green
White/Brown
Brown
4
5
2
7
8
BD4+
BD4TXBD3+
BD3-
161
162
163
Driver Version:
Version
Date
1.00
Jun/16/2009
Description of Changes
Add address type [S], [SM], [D_bit]
164
MITSUBISHI FX0n/FX2
Mitsubishi FX0s/FX0n/FX1s/FX2 PLC
http://www.mitsubishi-automation.com
HMI Setting:
Parameters
Recommend
Option
Notes
PLC type
Mitsubishi FX0n/FX2
Mitsubishi FX0n/FX2
Com port
RS485
RS232/RS485
Baud rate
9600
9600/19200/38400/57600/
115200
Parity bit
Even
Data Bits
7,8
Stop Bits
1,2
0-255
0-255
PLC Setting:
Communication mode
9600,Even,7,1
Device address:
Bit/Word
Device
Type
Format
Range
Memo
ooo
0-377
Input Relay
ooo
0-377
Output Relay
ddd
0-9999
Auxiliary Relay
ddd
0-255
Timer Relay
ddd
0-255
Counter Relay
D_Bit
dddd(dd)
0-9999(0~15)
dddd
0-4095
SM
dddd
8000-9999
TV
ddd
0-255
Timer Memory
CV
ddd
0-199
Counter Memory
ddd
0-9999
Data Register
DW
CV2
ddd
200-255
165
SD
ddd
8000-9999
Wiring diagram:
MT8000
COM1 [RS-485] 4w
RS422 Port
9P D-SUB
8P MiniDin Female
RX-
TX-
RX+
TX+
GND
GND
TX-
RX-
TX+
RX+
Driver Version:
Version
Date
1.10
August 27.2009
Description of Changes
Add address type [S], [SM], [D_bit]
166
8Pin miniDin
Female
MITSUBISHI FX2n
Mitsubishi FX1n/FX2n series PLC
http://www.mitsubishi-automation.com
HMI Setting:
Parameters
Recommend
Option
Notes
PLC type
Mitsubishi FX2n
Mitsubishi FX2n
Com port
RS485
RS232/RS485
Baud rate
9600
9600/19200/38400/5760
0/115200
Parity bit
Even
Data Bits
Stop Bits
Online Simulator
YES
Broadcast command
NO
NO
PLC Setting:
Communication mode
9600,Even,7,1
Device address:
Bit/Word
Device
Type
Format
Range
Memo
ooo
0-377
Input Relay
ooo
0-377
Output Relay
dddd
0-7999
Auxiliary Relay
ddd
0-255
Timer Relay
ddd
0-255
Counter Relay
SM
dddd
8000-9999
D_Bit
dddd(dd)
0~7999(0~15)
dddd
0~4095
TV
ddd
0-255
Timer Memory
167
Bit/Word
Device
Type
Format
Range
Memo
CV
ddd
0-199
Counter Memory
ddd
0-7999
Data Register
DW
CV2
ddd
200-255
SD
ddd
8000-9999
Wiring diagram:
MT8000
COM1 [RS-485]4w
9P D-SUB
1
2
3
4
5
4
7
1
2
3
RXRX+
TXTX+
GND
TXTX+
RXRX+
GND
Driver Version:
Version
Date
V1.60
Sep/10/2009
Description of Changes
168
8Pin miniDin
Female
MITSUBISHI FX232/485BD
Mitsubishi FX0n/FX2/FX2n COM For Communication Module BD
FX2N-485-BD, FX2N-232-BD, FX1N-485-BD and FX1N-232-BD
http://www.mitsubishi-automation.com
HMI Setting:
Parameters
Recommend
PLC type
MITSUBISHI
Option
Notes
FX232/485BD
Com port
RS232/RS485
RS232/RS485 2w/4w
Baud rate
19200
9600/19200
Parity bit
Even
Data Bits
7,8
Stop Bits
1,2
YES
YES
Broadcast command
PLC Setting:
Communication mode
FX2N-485-BD, FX1N-485-BD
FX2N-232-BD, FX1N-232-BD
169
Device address:
Bit/Word
Device
Type
Format
Range
Memo
ooo
0-377
Input Relay
ooo
0-377
Output Relay
ddd
0-9999
Auxiliary Relay
ddd
0-255
Timer Relay
ddd
0-255
Counter Relay
TV
ddd
0-255
Timer Memory
CV
ddd
0-199
Counter Memory
ddd
0-9999
Data Register
CV2
ddd
200-255
Wiring diagram:
Communication Module RS232BD:
MT8000 RS232
9P D-SUB
COM1
COM2
232BD Module
9P D-SUB Female
COM3
3 TX
4 TX
7 TX
2 RX
6 RX
8 RX
5 GND 5 GND 5 GND
2 RXD
3 TXD
5 GND
485BD Module
RS-485 4w
5P terminal
9P D-SUB Male
1
RX-
SDB
RX+
SDA
TX-
RDB
TX+
RDA
GND
SG
170
RS485BD Module
9P D-SUB
5P terminal
COM1
COM3
RX-
Data-
SDB
RX+
Data+
SDA
TX-
RDB
TX+
RDA
GND
GND
SG
Driver Version:
Version
Date
V1.00
Dec/30/2008
Description of Changes
171
MITSUBISHI FX3U/FX3G
Mitsubishi FX3U/FX3UC/FX3G
http://www.mitsubishi-automation.com
HMI Setting:
Parameters
Recommend
PLC type
MITSUBISHI FX3u
Com port
RS485 4w
RS232/RS485 2w/4w
Baud rate
9600
9600/19200
Parity bit
Even
Data Bits
Stop Bits
Online Simulator
YES
Option
Notes
NO
PLC Setting:
Communication mode
9600,Even,7,1
Device address:
Bit/Word
Device
Type
Format
Range
Memo
ooo
0~377
Input Relay
ooo
0~377
Output Relay
dddd
0~7679
Auxiliary Relay
SM
dddd
8000~9999
dddd
0~4095
ddd
0~511
ddd
0~199
D_Bit
dddd(dd)
dddd=0~7999 (dd)=0~15
172
Bit/Word
Device
Type
Format
Range
Memo
TV
ddd
0~511
CV
ddd
0~199
DW
CV2
ddd
200~255
dddd
0~7999
SD
dddd
8000~9999
ddddd
0~32767
Wiring diagram:
MT8000
COM1[RS-485]4w
9P D-SUB
RX-
TX-
RX+
TX+
TX-
RX-
TX+
RX+
GND
GND
Driver Version:
Version
Date
V1.40
Apr/15/2009
Description of Changes
173
8Pin miniDin
Female
MITSUBISHI FX3U-ETHERNET
MITSUBISHI FX SERIES, Module: FX3U-ENET
http://www.mitsubishi-automation.com
HMI Setting:
Parameters
Recommend
PLC type
MITSUBISHI FX3u
Option
Notes
(Ethernet)
Com port
Ethernet
0 (default)
TCP/IP port
5001(default)
Device address:
Bit/Word
Device type
Format
Range
Memo
ooo
0 ~ 377
Input
ooo
0 ~ 377
Output Relay
dddd
0 ~ 7679
Internal Relay
dddd
0 ~ 4095
Step Relays
ddd
0 ~ 511
Timer Contacts
ddd
0 ~ 255
Counter Contacts
SM
dddd
8000 ~ 8511
D_Bit
dddd(dd)
0-799915
TV
ddd
0 ~ 511
Timer Value
ddddd
0 ~ 32767
File Register
CV
ddd
0 ~ 199
Counter Value
dddd
0 ~ 7999
Data Registers
CV2
ddd
200 ~255
Counter Value
SD
dddd
8000 ~ 8511
174
Wiring diagram:
Ethernet:
MT8000
Ethernet RJ45
Wire color
Ethernet Hub or
Switch RJ45
TX+
White/Orange
RX+
TX-
Orange
RX-
RX+
White/Green
TX+
BD4+
Blue
BD4+
BD4-
White/Blue
BD4-
RX-
Green
TX-
BD3+
White/Brown
BD3+
BD3-
Brown
BD3-
TX+
White/Orange
RX+
TX-
Orange
RX-
RX+
White/Green
TX+
BD4+
Blue
BD4+
BD4-
White/Blue
BD4-
RX-
Green
TX-
BD3+
White/Brown
BD3+
BD3-
Brown
BD3-
175
3. Users have to connect PLC via series port for setting IP address at first time.
176
4. After finishing the PLC settings, select Tools/FX special function utility/FX Configurator-EN
6. In Ethernet operational settings, select the related parameters and IP address and then
press End to finish the settings.
7. In Ethernet open settings, press End after setting the below parameters.
178
(The first Protocol means using GX Developer to communicate with module, The max. Fixed
buffer communication preocedure is 4 units.)
8. After setting the parameters to PLC, restart for using Ethernet communication.
179
Driver Version:
Version
Date
V1.00
Feb/12/2009
Description of Changes
180
HMI Setting:
Parameters
Recommend
Option
Notes
PLC type
MITSUBISHI Q00J
Com port
RS-232
CPU port
Baud rate
115200
9600,19200,38400,57600,115200
Data bit
Parity bit
Odd
Stop bit
Device address:
Bit/Word
Device Type
Format
Range
SM
dddd
0~1023
hhh
0 ~ 7FF
hhh
0 ~ 7FF
dddd
0 ~ 8191
dddd
0 ~ 2047
dddd
0 ~ 1023
dddd
0 ~ 1023
hhh
0 ~ 7FF
SB
hhh
0 ~ 3FF
SD
ddd
0~1023
hhh
0 ~ 7FF
dddd
0 ~ 511
SW
hhh
0 ~ 3FF
dddd
0~9
dddd
0 ~ 511
dddd
0 ~ 11135
181
Memo
Wiring diagram:
RS-232:
MT8000 RS232
Q00
9P D-SUB
CPU port
Mini-DIN 6pin
COM1
COM2
COM3
3 TX
4 TX
7 TX
2 RX
6 RX
8 RX
5 GND 5 GND 5 GND
3
4
5
RXD
TXD
GND
MINI-DIN 6Pin
Female
Driver Version:
Version
Date
V1.10
Sep/18/2009
Description of Changes
182
MITSUBISHI Q02H
Mitsubishi Q02H CPU port.
http://www.mitsubishi-automation.com
HMI Setting:
Parameters
Recommend
PLC type
MITSUBISHI Q02H
Com port
RS232
Baud rate
115200
115200 only
Parity bit
Odd
Data Bits
Stop Bits
Online Simulator
YES
Broadcast command
NO
Option
Notes
NO
PLC Setting:
Communication mode
Device address:
Bit/Word
Device Type
Format
Range
hhh
0~1FFF
Input Relay
hhh
0~1FFF
Output Relay
dddd
0~8191
Internal Relay
dddd
0~8191
Latch Relay
dddd
0~2047
Annunciator
dddd
0~2047
Edge Relay
hhh
0~1FFF
Link Relay
TC
ddd
0~2047
Timer Coil
SS
ddd
0~2047
SC
ddd
0~2047
CS
ddd
0~1023
Counter Contact
183
Memo
Bit/Word
Device Type
Format
Range
Memo
CC
ddd
0~1023
Counter Coil
SB
hhh
0~7FF
dddd
0~8191
Step Relay
DX
hhh
0~1FFF
Direct Input
DY
hhh
0~1FFF
Direct Output
TS
ddd
0~2047
Timer Contact
hhh
0~1FFF
Link Register
TN
ddd
0~2047
SN
ddd
0~2047
CN
ddd
0~1023
ddddd
0~32767
File Register
SW
hhh
0~7FF
0~9
ZR
hhhh
0~FFFF
File Register
ddddd
0~12287
Data Register
Wiring diagram:
RS-232:
MT8000 RS232
9P D-SUB
COM1
COM2
COM3
TX
TX
TX
RXD
RX
RX
RX
TXD
MINI-DIN 6Pin
GND
GND
GND
GND
Female
CTS
RTS
Q02
CPU port
Mini-DIN 6pin
Driver Version:
Version
Date
V1.40
Aug/19/2009
V1.50
Jan/05/2010
Description of Changes
184
HMI Setting:
Parameters
Recommend
Option
PLC type
MITSUBISHI Q02U
Com port
RS232
Baud rate
115200
115200 only
Notes
Parity bit
Odd
Data Bits
Stop Bits
No
Device address:
Bit/Word
Device Type
Format
Range
Memo
hhhh
0~1FFF
Input Relay
hhhh
0~1FFF
Output Relay
dddd
0~8191
Internal Relay
dddd
0~8191
Latch Relay
dddd
0~2047
Annunciator
dddd
0~2047
Edge Relay
hhhh
0~1FFF
Link Relay
SB
hhh
0~7FF
hhhh
0~1FFF
Link Register
dddd
0~0247
SW
hhh
0~7FF
dd
0~19
dddd
0~1023
ddddd
0~12287
Data Register
Index Register
the wiring diagram or the data are incorrect, it could cause PLC locked. If the PLC locked, users
have to restart PLC or reinstall PLC module.
Wiring diagram:
RS-232:
MT8000 RS232
9P D-SUB
COM1
COM2
COM3
TX
TX
TX
RXD
RX
RX
RX
TXD
MINI-DIN 6Pin
GND
GND
GND
GND
Female
CTS
RTS
Q02
CPU port
Mini-DIN 6pin
Driver Version:
Version
Date
V1.40
Jul/08/2009
Description of Changes
186
HMI Setting:
Parameters
Recommend
Option
PLC type
MITSUBISHI Q02U
Com port
RS232
Baud rate
115200
115200 only
Parity bit
Odd
Data Bits
Stop Bits
No
Notes
Device address:
Bit/Word
Device Type
Format
Range
Memo
hhhh
0~1FFF
Input Relay
hhhh
0~1FFF
Output Relay
dddd
0~8191
Internal Relay
dddd
0~8191
Latch Relay
dddd
0~2047
Annunciator
dddd
0~2047
Edge Relay
hhhh
0~1FFF
Link Relay
SB
hhh
0~7FF
hhhh
0~1FFF
Link Register
dddd
0~0247
SW
hhh
0~7FF
dd
0~19
dddd
0~1023
ddddd
0~12287
Data Register
Index Register
Driver Version:
Version
Date
V1.00
Feb/09/2010
Description of Changes
188
MITSUBISHI Q06H
Mitsubishi Q06H CPU port.
http://www.mitsubishi-automation.com
HMI Setting:
Parameters
Recommend
PLC type
MITSUBISHI Q06H
Com port
RS232
Baud rate
115200
115200 only
Parity bit
Odd
Data Bits
Stop Bits
Online Simulator
YES
Broadcast command
NO
Option
Notes
NO
PLC Setting:
Communication mode
Device address:
Bit/Word
Device Type
Format
Range
hhh
0~1FFF
Input Relay
hhh
0~1FFF
Output Relay
dddd
0~8191
Internal Relay
dddd
0~8191
Latch Relay
dddd
0~2047
Annunciator
dddd
0~2047
Edge Relay
hhh
0~1FFF
Link Relay
TC
ddd
0~2047
Timer Coil
SS
ddd
0~2047
SC
ddd
0~2047
189
Memo
Bit/Word
Device Type
Format
Range
Memo
CS
ddd
0~1023
Counter Contact
CC
ddd
0~1023
Counter Coil
SB
hhh
0~7FF
dddd
0~8191
Step Relay
DX
hhh
0~1FFF
Direct Input
DY
hhh
0~1FFF
Direct Output
TS
ddd
0~2047
Timer Contact
hhh
0~1FFF
Link Register
TN
ddd
0~2047
SN
ddd
0~2047
CN
ddd
0~1023
ddddd
0~32767
File Register
SW
hhh
0~7FF
0~9
ZR
hhhh
0~FFFF
File Register
ddddd
0~12287
Data Register
Wiring diagram:
RS-232:
MT8000 RS232
9P D-SUB
COM1
COM2
COM3
TX
TX
TX
RXD
RX
RX
RX
TXD
MINI-DIN 6Pin
GND
GND
GND
GND
Female
CTS
RTS
Q02
CPU port
Mini-DIN 6pin
Driver Version:
Version
Date
V1.40
Jun/03/2009
Description of Changes
190
MITSUBISHI Q00/Q00UJ/Q01/QJ71
Mitsubishi Q series PLC with QJ71C24 communication module, Q00, Q00UJ, Q01 CPU port.
http://www.mitsubishi-automation.com
HMI Setting:
Parameters
Recommend
PLC type
MITSUBISHI
Option
Notes
Melsec_QJ71
Com port
RS232
Baud rate
9600
9600~115200
Parity bit
Odd
Data Bits
Stop Bits
Online Simulator
YES
NO
PLC Setting:
Communication mode
Device address:
Bit/Word
Device Type
Format
Range
hhh
0~1FFF
Input Relay
hhh
0~1FFF
Output Relay
dddd
0~8191
Internal Relay
dddd
0~8191
Latch Relay
dddd
0~2047
Annunciator
dddd
0~2047
Edge Relay
hhh
0~1FFF
Link Relay
TC
ddd
0~2047
Timer Coil
SS
ddd
0~2047
SC
ddd
0~2047
CS
ddd
0~1023
Counter Contact
CC
ddd
0~1023
Counter Coil
SB
hhh
0~7FF
dddd
0~8191
Step Relay
DX
hhh
0~1FFF
Direct Input
DY
hhh
0~1FFF
Direct Output
TS
ddd
0~2047
Timer Contact
hhh
0~1FFF
Link Register
TN
ddd
0~2047
SN
ddd
0~2047
CN
ddd
0~1023
192
Memo
Bit/Word
Device Type
Format
Range
Memo
ddddd
0~32767
SW
hhh
0~7FF
0~9
ZR
hhhh
0~FFFF
File Register
ddddd
0~12287
Data Register
File Register
Special Link Register
Index Register
Wiring diagram:
RS-485 4W:
MT8000 COM1
QJ71C24 CH.2
RS-485 4w
RS-422
9P D-SUB Male
1
RX-
SDB
RX+
SDA
TX-
RDB
TX+
RDA
GND
GND
RS-232:
QJ71C24 CH.1
RS232 port
9P D-SUB Male
MT8000 RS232
9P D-SUB
COM1
COM2
COM3
TX
TX
TX
RXD
RX
RX
RX
TXD
GND
GND
DCD
DTR
DSR
RTS
CTS
GND
GND
Q00, Q01
CPU port
Mini-DIN 6pin
MT8000 RS232
9P D-SUB
COM1
COM2
COM3
TX
TX
TX
RXD
RX
RX
RX
TXD
MINI-DIN 6Pin
GND
GND
Female
GND
GND
COM3
TX
TX
TX
RXD
RX
RX
RX
TXD
MINI-DIN 6Pin
GND
GND
GND
GND
Female
CTS
RTS
Q00UJ
CPU port
Mini-DIN 6pin
Driver Version:
Version
Date
V1.20
Dec/30/2008
Description of Changes
194
MITSUBISHI QJ71E71
Mitsubishi Q type, QJ71E71-100 Ethernet module.
http://www.mitsubishi-automation.com
HMI Setting:
Parameters
Recommend
PLC type
MITSUBISHI QJ71E71
Option
Notes
[V1.00]
Com port
Ethernet
TCP/IP port
5002
1~99
Device address:
Bit/Word
Device Type
Format
Range
hhhh
0~1FFF
Input Relay
hhhh
0~1FFF
Output Relay
dddd
0~8191
Internal Relay
dddd
0~8191
Latch Relay
dddd
0~2047
Annunciator
dddd
0~2047
Edge Relay
hhhh
0~1FFF
Link Relay
SB
hhhh
0~2047
DX
hhhh
0~1FFF
Direct Input
DY
hhhh
0~1FFF
Direct Output
hhhh
0~2FFF
Link Register
dddd
0~32767
File Register
SW
hhh
0~7FF
dd
0~15
ZR
hhhh
0~FFFF
File Register
ddddd
0~12287
Data Register
195
Memo
Wiring diagram:
Ethernet:
MT8000 Ethernet Wire color
Ethernet Hub or
RJ45
Switch RJ45
1
2
3
TX+
TXRX+
White/Orange
Orange
White/Green
1
2
3
RX+
RXTX+
4
5
6
7
8
BD4+
BD4RXBD3+
BD3-
Blue
White/Blue
Green
White/Brown
Brown
4
5
6
7
8
BD4+
BD4TXBD3+
BD3-
RJ45
1
2
3
4
5
6
7
8
TX+
TXRX+
BD4+
BD4RXBD3+
BD3-
White/Orange
Orange
White/Green
Blue
White/Blue
Green
White/Brown
Brown
3
6
1
4
5
2
7
8
RX+
RXTX+
BD4+
BD4TXBD3+
BD3-
1.
2.
197
3.
4.
198
5.
199
6.
Restart PLC software and select [READ FROM PLC], click QCPU(Qmode) and
press OK.
7.
Select Ethernet board in PC Side I/F to set Network and Station no..(the Station
no.1 is PCs station no. not Ethernet modules, range from 2~64, the Network no.
can not the same as PCs number)
8.
Select Ethernet module in PLC Side I/F to set QJ71E71s IP address.(IP address
= Network Parameters IP address)
9.
After finishing settings as above, click Connection test for testing the
communication and sending the PLCs program.
Driver Version:
Version
Date
V2.10
Feb/05/2009
Description of Changes
201
MODBUS ASCII
MODBUS ASCII CONTROLLER
http://www.modbus.org
HMI Setting:
Parameters
Recommend
Option
PLC type
Modbus ASCII
Com port
RS485
RS232/RS485
Baud rate
9600
9600/19200/38400/57600/
Notes
115200
Parity bit
Even
Data Bits
7,8
Stop Bits
1,2
0-255
Online Simulator
YES
YES
Broadcast command
YES
PLC Setting:
Communication mode
Device address:
Bit/Word
Device Type
Format
Range
Memo
0x
ddddd
1-65535
Output bit
1x
ddddd
1-65535
3x_Bit
ddddd(dd)
100-6553515
4x_Bit
ddddd(dd)
100-6553515
3x
ddddd
1-65535
4x
ddddd
1-65535
Output Register
202
3x
0x04 Read input register
4x
0x03 Read holding register
3xbit is equivalent to 3x
4xbit is equivalent to 4x
Wiring diagram:
MODBUS RS232 PORT
MT8000 RS-232
Modbus ASCII
9P D-SUB
Controller RS232
COM1
COM2
COM3
Port
TX
TX
TX
RXD
RX
RX
RX
TXD
GND
GND
GND
GND
RTS
CTS
COM1 RS-485 4w
RS422 Port
RX-
TX-
RX+
TX+
TX-
RX-
TX+
RX+
GND
GND
Modbus ASCII
9P D-SUB
Controller RS485
COM1
COM3
RX-
Data-
D-
RX+
Data+
D+
GND
GND
GND
203
Driver Version:
Version
Date
V1.40
Apr/17/2009
Description of Changes
204
MODBUS RTU
MODBUS RTU CONTROLLER
http://www.modbus.org
HMI Setting:
Parameters
Recommend
Option
PLC type
Modbus RTU
Com port
RS485
RS232/RS485
Baud rate
9600
9600~115200
Parity bit
Even
Data Bits
7,8
Stop Bits
1,2
Notes
0-255
Online Simulator
YES
YES
Broadcast command
YES
PLC Setting:
Communication mode
Device address:
Bit/Word
Device Type
Format
Range
0x
ddddd
1-65535
Output bit
0x_multi_coils
ddddd
1-65535
1x
ddddd
1-65535
3x_Bit
ddddd(dd)
100-6553515
4x_Bit
ddddd(dd)
100-6553515
6x_Bit
ddddd(dd)
100-6553515
3x
ddddd
1-65535
4x
ddddd
1-65535
Output Register
DW
5x
ddddd
1-65535
6x
ddddd
1-65535
4x_32Bit
ddddd
1-65535
205
Memo
NOTE:
Address type 5x are mapping to Hold Reg. The communication protocol of 5x is almost same as
4x except 5xmaking double word swap.
If 4x has following information
Address
Data in word
0x1
0x2
0x3
0x4
0x5
0x6
Data
0x20001
0x40003
0x60005
Address
Data in word
0x2
0x1
0x4
0x3
0x6
0x5
...
Data
0x10002
0x30004
...
0x50006
3x
4x
5x
0x03 Read holding register
0x10 write multiple register
( note: reverse word order in double word format)
3xbit is equivalent to 3x
4xbit is equivalent to 4x
6x
0x03 Read holding register
Wiring diagram:
MODBUS RS232 PORT
MT8000 RS-232
Modbus RTU
9P D-SUB
Controller RS232
COM1
COM2
COM3
Port
TX
TX
TX
RXD
RX
RX
RX
TXD
GND
GND
GND
GND
RTS
CTS
206
COM1 RS-485 4w
RS422 Port
RX-
TX-
RX+
TX+
TX-
RX-
TX+
RX+
GND
GND
Modbus RTU
9P D-SUB
Controller RS485
COM1
COM3
RX-
Data-
D-
RX+
Data+
D+
GND
GND
GND
Driver Version:
Version
Date
V1.70
Aug/26/2009
V1.80
V1.90
Description of Changes
Fixed when receiving data from modbus rtu over 8 bytes, LW9570
can not calculate correctly.
207
HMI Setting:
Parameters
Recommend
Option
PLC type
Modbus RTU
Com port
RS485
RS232/RS485
Baud rate
9600
9600~115200
Parity bit
Even
Data Bits
7,8
Stop Bits
1,2
Notes
0-255
Online Simulator
YES
YES
Broadcast command
YES
PLC Setting:
Communication mode
Device address:
Bit/Word
Device Type
Format
Range
0x
ddddd
0-65535
Output bit
1x
ddddd
0-65535
0x_multi_coils
ddddd
1-65535
3x_Bit
ddddd(dd)
0-6553515
4x_Bit
ddddd(dd)
0-6553515
3x
ddddd
0-65535
4x
ddddd
0-65535
Output Register
DW
5x
ddddd
0-65535
6x
ddddd
0-65535
208
Memo
NOTE:
Address type 5x are mapping to Hold Reg. The communication protocol of 5x almost same as
4x except 5xmaking double word swap.
If 4x have following information
Address
Data in word
0x1
0x2
0x3
0x4
0x5
0x6
Data
0x20001
0x40003
0x60005
Address
Data in word
0x2
0x1
0x4
0x3
0x6
0x5
...
Data
0x10002
0x30004
...
0x50006
3x
4x
5x
0x03 Read holding register
0x10 write multiple register
(Note: reverse word order in double word format)
3xbit is equivalent to 3x
4xbit is equivalent to 4x
6x
0x03 Read holding register
Wiring diagram:
MODBUS RS232 PORT
MT8000 RS-232
Modbus RTU
9P D-SUB
Controller RS232
COM1
COM2
COM3
Port
TX
TX
TX
RXD
RX
RX
RX
TXD
GND
GND
GND
GND
RTS
CTS
209
COM1 RS-485 4w
RS422 Port
RX-
TX-
RX+
TX+
TX-
RX-
TX+
RX+
GND
GND
Modbus RTU
9P D-SUB
Controller RS485
COM1
COM3
RX-
Data-
D-
RX+
Data+
D+
GND
GND
GND
210
Driver Version:
Version
Date
V1.30
Aug/26/2009
Description of Changes
211
Recommend
Option
Option
PLC type
Modbus Server
Com port
RS232
RS232, RS485
Ethernet
Baud rate
9600
9600~115200
Parity bit
Even
Data Bits
Stop Bits
Notes
0
1-31
Port no.
502
Online Simulator
YES
Broadcast command
NO
NO
PLC Setting:
Communication mode
Device address:
Bit/Word
Device Type
Format
Range
Memo
LB
dddd
0~9998
LW
dddd
0~9998
RW
ddddd
0~55536
212
Wiring diagram:
RS-232:
Modbus RTU RS232
9P D-SUB
MT8000 RS232
9P D-SUB
COM1
COM2
COM3
3 TX
2 RX
5 GND
4 TX
6 RX
5 GND
7 TX
8 RX
5 GND
RX
TX
GND
RS-485:
MT8000 RS485 2w
9P D-SUB
9P D-SUB
COM1
COM3
RX-
Data-
Data-
RX+
Data+
Data+
GND
GND
GND
Precaution: Setting more than one Modbus server in HMI device list is useless.
Driver Version:
Version
Date
V1.00
Dec/30/2008
Description of Changes
213
MODBUS TCP/IP
Modbus RTU TCP/IP device.
http://www.modbus.org
HMI Setting:
Parameters
Recommend
Option
PLC type
MODBUS TCP/IP
Com port
Ethernet
0~255
TCP/IP port
502
Notes
PLC Setting:
Communication mode
Device address:
Bit/Word
Device Type
Format
Range
0x
ddddd
1-65535
Output bit
0x_multi_coils
ddddd
1-65535
1x
ddddd dd
1-65535
3x_bit
ddddd dd
100-6553515
4x_bit
ddddd dd
100-6553515
6x_bit
ddddd dd
100-6553515
3x
Ddddd
1-65535
4x
Ddddd
1-65535
Output Register
DW
5x
Ddddd
1-65535
6x
Ddddd
1-65535
214
Memo
Wiring diagram:
Ethernet::
Wire color
MT8000 Ethernet
RJ45
RJ45
TX+
White/Orange
RX+
TX-
Orange
RX-
RX+
White/Green
TX+
BD4+
Blue
BD4+
BD4-
White/Blue
BD4-
RX-
Green
TX-
BD3+
White/Brown
BD3+
BD3-
Brown
BD3-
MT8000 Ethernet
RJ45
RJ45
TX+
White/Orange
RX+
TX-
Orange
RX-
RX+
White/Green
TX+
BD4+
Blue
BD4+
BD4-
White/Blue
BD4-
RX-
Green
TX-
BD3+
White/Brown
BD3+
BD3-
Brown
BD3-
Driver Version:
Version
Date
V1.50
Aug/26/2009
Description of Changes
215
8
RJ45
connector
MODBUS TCP/IP
Modbus RTU TCP/IP device.
http://www.modbus.org
HMI Setting:
Parameters
Recommend
Option
PLC type
MODBUS TCP/IP
Com port
Ethernet
0~255
TCP/IP port
502
Notes
PLC Setting:
Communication mode
Device address:
Bit/Word
B
B
B
B
B
B
W
W
DW
W
Device Type
1x
0x
0x_multi_coils
3x_bit
4x_bit
6x_bit
3x
4x
5x
6x
Format
ddddd
ddddd dd
ddddd
ddddd dd
ddddd dd
Ddddd dd
ddddd
ddddd
ddddd
ddddd
Range
1-65535
1-65535
1-65535
100-6553515
100-6553515
100-6553515
1-65535
1-65535
1-65535
1-65535
216
Memo
Output bit
Input bit
Write Multiple Coils
Input Register bit (read only)
Output Register bit
Output Register bit
Input Register
Output Register
4x double word swap
4x single word write
Wiring diagram:
Ethernet:
MT8000 Ethernet
RJ45
Wire color
TX+
White/Orange
RX+
TX-
Orange
RX-
RX+
White/Green
TX+
BD4+
Blue
BD4+
BD4-
White/Blue
BD4-
RX-
Green
TX-
BD3+
White/Brown
BD3+
BD3-
Brown
BD3-
Wire color
TX+
White/Orange
RX+
TX-
Orange
RX-
RX+
White/Green
TX+
BD4+
Blue
BD4+
BD4-
White/Blue
BD4-
RX-
Green
TX-
BD3+
White/Brown
BD3+
BD3-
Brown
BD3-
217
RJ45
connector
HMI Setting:
Parameters
Recommend
Option
PLC type
MODBUS TCP/IP
Com port
Ethernet
0~255
TCP/IP port
502
Notes
PLC Setting:
Communication mode
Device address:
Bit/Word
B
B
B
B
B
B
W
W
DW
W
W
Device Type
1x
0x
0x_multi_coils
3x_bit
4x_bit
6x_bit
3x
4x
5x
6x
4x_32Bit
Format
ddddd
ddddd dd
ddddd
ddddd dd
ddddd dd
ddddd dd
ddddd
ddddd
ddddd
ddddd
ddddd
Range
1-65535
1-65535
1-65535
100-6553515
100-6553515
100-6553515
1-65535
1-65535
1-65535
1-65535
1-65535
218
Memo
Output bit
Input bit
Write Multiple Coils
Input Register bit (read only)
Output Register bit
Output Register bit
Input Register
Output Register
4x double word swap
4x single word write
4x High/low byte swap
Wiring diagram:
Ethernet:
MT8000 Ethernet Wire color
RJ45
TX+
White/Orange
RX+
TX-
Orange
RX-
RX+
White/Green
TX+
BD4+
Blue
BD4+
BD4-
White/Blue
BD4-
RX-
Green
TX-
BD3+
White/Brown
BD3+
BD3-
Brown
BD3-
TX+
White/Orange
RX+
TX-
Orange
RX-
RX+
White/Green
TX+
BD4+
Blue
BD4+
BD4-
White/Blue
BD4-
RX-
Green
TX-
BD3+
White/Brown
BD3+
BD3-
Brown
BD3-
219
RJ45
connector
HMI Setting:
Parameters
Recommend
Option
PLC type
MODBUS TCP/IP
Com port
Ethernet
0~255
TCP/IP port
502
Notes
PLC Setting:
Communication mode
Device address:
Bit/Word
Device Type
Format
Range
Memo
0x
ddddd
0-65535
Output bit
1x
ddddd dd
0-65535
3x_bit
ddddd dd
0-6553515
4x_bit
ddddd
0-6553515
3x
ddddd
0-65535
4x
ddddd
0-65535
Output Register
DW
5x
ddddd
0-65535
Wiring diagram:
Ethernet::
MT8000 Ethernet
Wire color
RJ45
RJ45
TX+
White/Orange
RX+
TX-
Orange
RX-
RX+
White/Green
TX+
BD4+
Blue
BD4+
BD4-
White/Blue
BD4-
RX-
Green
TX-
BD3+
White/Brown
BD3+
220
RJ45
connector
BD3-
Brown
BD3-
MT8000 Ethernet
RJ45
RJ45
TX+
White/Orange
RX+
TX-
Orange
RX-
RX+
White/Green
TX+
BD4+
Blue
BD4+
BD4-
White/Blue
BD4-
RX-
Green
TX-
BD3+
White/Brown
BD3+
BD3-
Brown
BD3-
Driver Version:
Version
Date
V1.40
Aug/27/2009
Description of Changes
221
Moeller XC-CPU101
MOELLER XC100/200 series
http://www.moeller.net
HMI Setting:
Parameters
Recommend
Option
PLC type
Moeller XC-CPU101
Com port
RS232
Baud rate
38400
Parity bit
None
Data Bits
Stop Bits
Notes
4800~57600
PLC Setting:
Communication mode
Device address:
Bit/Word
B
B
W
W
W
Device Type
QX
IX
MW
QW
IW
Format
ddo
ddo
dddd
dd
dd
Range
dd:0~15, o:0~7
dd:0~15, o:0~7
1~4095
0~15
0~15
Wiring diagram:
RS-232:
CPU RS-232
8P RJ45
MT8000 RS232
9P D-SUB
COM1
COM2
COM3
3 TX
2 RX
5 GND
4 TX
6 RX
5 GND
7 TX
8 RX
5 GND
8
5
4
222
RD
TD
GND
RJ45
connector
Driver Version:
Version
Date
1.00
Apr/01/2010
Description of Changes
223
Modicon Twido
http://www.modicon.com/
HMI Setting:
Parameters
PLC type
Com port
Baud rate
Parity bit
Data Bits
Stop Bits
HMI Station No.
PLC Station No.
Recommend
Modbus RTU
RS485
19200
None
8
1
0
1
Option
RS232/RS485
19200
Even, Odd, None
8
1
0-247
Notes
Support Extended Address mode.
Must match the PLCs port setting.
Must match the PLCs port setting.
Must match the PLCs port setting.
Must set 8 for RTU mode
Must set 8 for RTU mode
Does not apply to this protocol.
Must match the PLCs port setting.
PLC Setting:
Communication mode
19200, None, 8, 1
Modbus RTU Slave
Select
Device address:
Bit/Word
B
W
Device
Type
0x or 1x
3x or 4x
Format
Range
Memo
dddd
dddd
0~9999
0~9999
%Mi
%MWi
224
Wiring diagram:
MT8000 RS-485
9P D-SUB
COM1
COM3
RX-
Data-
B(-)
RX+
Data+
A(+)
GND
GND
DTP
7 GND
MT8000 RS-485
9P D-SUB
COM1
COM3
RX-
RX+
GND
Data-
Data+
GND
B(-)
A(+)
GND
MT8000 RS232
9P D-SUB Female
COM1
COM2
COM3
Port2 RS232
9P D-SUB Female
TX
4 TX
7 TX
RX
RX
6 RX
8 RX
TX
5 GND
5 GND
GND
5 GND
225
HMI Setting:
Parameters
Recommend
PLC type
OMRON C/CQM1
Option
Notes
Series
Com port
RS232
Baud rate
9600
9600, 19200
Parity bit
Even
Data Bits
7 or 8
Stop Bits
1 or 2
0-31
Online Simulator
YES
YES
Broadcast command
YES
PLC Setting:
Communication mode
Device address:
Bit/Word
Device
Type
Format
Range
IR
ddd(dd)
0-409515
HR
ddd(dd)
0-409515
Hold Relay
AR
ddd(dd)
0-409515
Auxiliary Relay
LR
ddd(dd)
0-409515
Link Relay
TC
ddd
0-519
Timer/Counter Register
DM
dddd
0-6659
Data register
226
Memo
Wiring diagram:
CPU Port(CPM2A,CQM1/1H,C200H/HS/ALPHA series)
Communication Module:
CPM1-CIF01 adapter(for CPM1/CPM1A/CPM2A series,CQM1/CQM1H series)
CPM1H-SCB41 communication module(for CQM1H-CPU51/61)
OMRON
CPU RS-232 9P
D-SUB Female
MT8000 RS232
9P D-SUB Female
COM1
COM2
COM3
3 TX
2 RX
5 GND
4 TX
6 RX
5 GND
7 TX
8 RX
5 GND
RD
SD
GND
RS
CS
MT8000 RS232
9P D-SUB Female
COM1
COM2
COM3
3 TX
2 RX
5 GND
4 TX
6 RX
5 GND
7 TX
8 RX
5 GND
Driver Version:
Version
Date
V1.60
Sep/25/2009
Description of Changes
227
RD
SD
GND
RS
CS
OMRON CJ1/CS1
OMRON CP1L, CP1H, CJ1M, CJ1H, CJ1G, CS1H and CS1G. (Host Link Protocol FINS
command), this driver supports Extend Addressing mode.
http://oeiweb.omron.com/oei/Products-PLC.htm
HMI Setting:
Parameters
Recommend
Option
PLC type
OMRON CJ1/CS1
Com port
RS232
Baud rate
9600
9600~115200
Parity bit
Even
Data Bits
7 or 8
Stop Bits
1 or 2
Notes
0-31
Online Simulator
YES
Broadcast command
NO
YES
PLC Setting:
Communication mode
Device address:
Bit/Word
Device Type
Format
Range
Bit
D_bit
ddd(dd)
Bit
H_bit
ddd(dd)
Bit
W_bit
ddd(dd)
Bit
CIO_bit
ddd(dd)
Bit
A_bit
ddd(dd)
Bit
T_bit
ddd
ddd:0~4095
Timer (TIM)
Bit
C_bit
ddd
ddd:0~4095
Counter (CNT)
Word
ddd
ddd:0~32767
Word
ddd
ddd:0~511
228
Memo
Bit/Word
Device Type
Format
Range
Memo
Word
ddd
ddd:0~511
Word
CIO
ddd
ddd:0~6143
Word
ddd
ddd:0~959
Word
ddd
ddd:0~4095
Timer (TIM)
Word
ddd
ddd:0~4095
Counter (CNT)
Word
EM0~EMC
dddd
dddd:0-6149
Extend Memory
Wiring diagram:
RS-232:
OMRON
CPU RS-232 9P
D-SUB Female
MT8000 RS232
9P D-SUB Female
COM1
COM2
COM3
TX
TX
TX
RD
RX
RX
RX
SD
GND
GND
RS
CS
GND
GND
CP1W-CIF11
COM1 [RS-485] 4w
RS422 Port
9P D-SUB Male
1
RX-
SDA
RX+
SDB
TX-
RDA
TX+
RDB
GND
FG
Driver Version:
Version
Date
V1.40
Arp/17/2009
Description of Changes
229
CP1W-CIF11
SW1 ON
OFF
OFF
OFF
OFF
OFF
HMI Setting:
Parameters
Recommend
PLC type
OMRON CJ1/CS1
Option
Notes
(Ethernet)
Com port
Ethernet
TCP port
9600
PLC Setting:
Communication mode
Device address:
Bit/Word
Device Type
Format
Range
Memo
D_bit
ddddd(dd)
H_bit
ddd(dd)
W_bit
ddd(dd)
CIO_bit
dddd(dd)
A_bit
ddd(dd)
T_bit
dddd
ddd:0~4095
Timer (TIM)
C_bit
dddd
ddd:0~4095
Counter (CNT)
ddddd
ddd:0~32767
ddd
ddd:0~511
ddd
ddd:0~511
CIO
dddd
ddd:0~6143
ddd
ddd:0~959
dddd
ddd:0~4095
Timer (TIM)
dddd
ddd:0~4095
Counter (CNT)
230
Wiring diagram:
Ethernet:
MT8000 Ethernet
Wire color
RJ45
RJ45
TX+
White/Orange
RX+
TX-
Orange
RX-
RX+
White/Green
TX+
BD4+
Blue
BD4+
BD4-
White/Blue
BD4-
RX-
Green
TX-
BD3+
White/Brown
BD3+
BD3-
Brown
BD3-
Wire color
OMRON Ethernet
RJ45
RJ45
TX+
White/Orange
RX+
TX-
Orange
RX-
RX+
White/Green
TX+
BD4+
Blue
BD4+
BD4-
White/Blue
BD4-
RX-
Green
TX-
231
RJ45
connector
BD3+
White/Brown
BD3+
BD3-
Brown
BD3-
Driver Version:
Version
Date
V1.00
Dec/30/2008
Description of Changes
232
OMRON E5CN
OMRON E5CN series Temperature controller with communication option.
E5EN/CN/GN series
http://oeiweb.omron.com
HMI Setting:
Parameters
Recommend
PLC type
OMRON E5CN
Com port
RS485 2W
Baud rate
9600
Option
Notes
9600/19200/38400/57600
/115200
Parity bit
Even
Data Bits
7,8
Stop Bits
1,2
0-99
Online Simulator
YES
YES
Broadcast command
YES
PLC Setting:
Communication mode
Device address:
Bit/Word
Device Type
Format
Range
Status
dd
0-31
Page40
DW
C0
hhhh
0-5
DW
C1
hhhh
0-1C
DW
C3
hhhh
0-1D
Operation00_00
hh
Operation00_01
hh
Operation01_00
hh
Run
Operation01_01
hh
Stop
Operation02_00
hh
233
Memo
Bit/Word
Device Type
Format
Range
Memo
Operation02_01
hh
Operation02_02
hh
Operation02_03
hh
Operation03_00
hh
AT cancel
Operation03_01
hh
AT execute
Operation04_00
hh
Operation04_01
hh
Operation05_00
hh
Operation06_00
hh
Software reset
Operation07_00
hh
Operation08_00
hh
Wiring diagram:
MT8000 RS-485 2Wire
OMRON E5CN
9P D-SUB
COM1
COM3
RX-
Data-
12
RX+
Data+
11
GND
GND
GND
Driver Version:
Version
Date
V1.20
Sep/16/2009
Description of Changes
234
Panasonic FP
NAIS(Matsushita) FP series include FP-X, FP-, FP0, FP1, FP2, FP2SH, FP10SH and FP3
Ethernet support FP-X with AFPX-COM5.
http://pewa.panasonic.com/
HMI Setting:
Parameters
Recommend
Option
Notes
PLC type
Panasonic FP
Com port
RS232
RS232/RS485 Ethernet
Baud rate
9600
115200
Parity bit
Odd
Data Bits
7 or 8
Stop Bits
1 or 2
0-255
0-255
PLC Setting:
Communication
mode
9600,O,8,1(default)
Device address:
Bit/Word
Device
Type
Format
dddd(h)
0~9999F
Input(X)
dddd(h)
0~9999F
Output(Y)
dddd(h)
0~9999F
Internal Relay(R)
dddd
0~9999
Link Relay(L)
L_Bit
dddd(h)
0~9999F
dddd
0~9999
Timer(T)
dddd
0~9999
Counter(C)
SV
dddd
0~9999
EV
ddddd
0~65535
Timer/Counter elapse
DT
ddddd
0~99999
Data Register(DT)
LD
dddd
0~8447
Link Register(LD)
Range
Memo
value(EV)
235
WX
dddd
0~9999
WY
dddd
0~9999
Output(WY)
WR
dddd
0~9999
Internal Relay(WR)
WL
dddd
0~9999
Link Relay(WL)
FL
ddddd
0~99999
File register(FL)
Wiring diagram:
MT8000 RS232
9P D-SUB
COM1
COM2
COM3
TX
TX
TX
RXD
RX
RX
RX
TXD
GND
GND
Female
GND
GND
MT8000 RS232
9P D-SUB
3P terminal
COM1
COM2
COM3
TX
TX
TX
RX
RX
RX
GND
GND
GND
MT8000 RS232
9P D-SUB
COM1
COM2
COM3
TX
TX
TX
RXD
RX
RX
RX
TXD
GND
GND
RTS
CTS
CD
ER
GND
GND
236
MT8000
COM1[RS-485]4w 9P
D-SUB
1 RX-
TXDA
2 RX+
TXDB
3 TX-
RXDA
4 TX+
RXDB
5 GND
GND
MT8000
COM1[RS-485]4w 9P
D-SUB
1 RX-
TXDA
2 RX+
TXDB
3 TX-
10
RXDA
4 TX+
RXDB
5 GND
GND
RTS+
CTS+
11
RTS12
CTS-
Driver Version:
Version
Date
V1.40
Jul/23/2009
V1.80
Apr/12/2010
Description of Changes
237
Panasonic FP Ethernet
NAIS(Matsushita) FP series include FP-X, FP-, FP0, FP1, FP2, FP2SH, FP10SH and FP3
Ethernet support FP-X with AFPX-COM5.
http://pewa.panasonic.com/
HMI Setting:
Parameters
Recommend
PLC type
Panasonic FP
Com port
Ethernet
Port no.
Option
Notes
9094
0~255
PLC Setting:
Communication mode
Device address:
Bit/Word
Device
Type
Format
dddd(h)
0~9999F
Input(X)
dddd(h)
0~9999F
Output(Y)
dddd(h)
0~9999F
Internal Relay(R)
dddd
0~9999
Link Relay(L)
L_Bit
dddd(h)
0~9999F
dddd
0~9999
Timer(T)
dddd
0~9999
Counter(C)
SV
dddd
0~9999
EV
ddddd
0~65535
DT
ddddd
0~99999
Data Register(DT)
LD
dddd
0~8447
Link Register(LD)
WX
dddd
0~9999
WY
dddd
0~9999
Output(WY)
WR
dddd
0~9999
Internal Relay(WR)
WL
dddd
0~9999
Link Relay(WL)
FL
ddddd
0~99999
File register(FL)
Range
238
Memo
Wiring diagram:
Ethernet:
MT8000 Ethernet Wire color
RJ45
1
TX+
White/Orange
Ethernet Hub or
Switch RJ45
RX+
1
TX-
Orange
RX+
White/Green
TX+
BD4+
Blue
BD4+
BD4-
White/Blue
BD4-
RX-
Green
TX-
BD3+
White/Brown
BD3+
BD3-
Brown
BD3-
RXRJ45
XGL-EFMT
RJ45
TX+
White/Orange
RX+
TX-
Orange
RX-
RX+
White/Green
TX+
BD4+
Blue
BD4+
BD4-
White/Blue
BD4-
RX-
Green
TX-
BD3+
White/Brown
BD3+
BD3-
Brown
BD3-
239
Ethernet connect
TCP port: 9094
Ethern
et
MT8000
RS232
AFPX-COM5
Driver Version:
Version
Date
1.80
April. 12.2010
Description of Changes
240
FP-X
HMI Setting:
Parameters
Recommend
PLC type
Panasonic FP
Com port
Ethernet
Port no.
Option
Notes
8500
0~255
PLC Setting:
Communication mode
Device address:
Bit/Word
Device
Type
Format
Range
Memo
dddd(h)
0~9999F
Input(X)
dddd(h)
0~9999F
Output(Y)
dddd(h)
0~9999F
Internal Relay(R)
dddd
0~9999
Link Relay(L)
L_Bit
dddd(h)
0~9999F
dddd
0~9999
Timer(T)
dddd
0~9999
Counter(C)
SV
dddd
0~9999
EV
ddddd
0~65535
DT
ddddd
0~99999
Data Register(DT)
LD
dddd
0~8447
Link Register(LD)
WX
dddd
0~9999
WY
dddd
0~9999
Output(WY)
WR
dddd
0~9999
Internal Relay(WR)
WL
dddd
0~9999
Link Relay(WL)
241
Wiring diagram:
Ethernet:
MT8000 Ethernet Wire color
RJ45
1
TX+
White/Orange
Ethernet Hub or
Switch RJ45
RX+
1
TX-
Orange
RX+
White/Green
TX+
BD4+
Blue
BD4+
BD4-
White/Blue
BD4-
RX-
Green
TX-
BD3+
White/Brown
BD3+
BD3-
Brown
BD3-
RXRJ45
XGL-EFMT
RJ45
TX+
White/Orange
RX+
TX-
Orange
RX-
RX+
White/Green
TX+
BD4+
Blue
BD4+
BD4-
White/Blue
BD4-
RX-
Green
TX-
BD3+
White/Brown
BD3+
BD3-
Brown
BD3-
242
Driver Version:
Version
Date
1.00
March. 15.2010
Description of Changes
243
HMI Setting:
Parameters
Recommend
PLC type
PANASONIC MINAS A4
Com port
RS232
Axis no.
Baud rate
9600
Parity bit
None
Data Bits
Stop bit
Option
Notes
0 ~ F (slave)
Device address:
Bit/Word
Device Type
Format
Range
Memo
Command 01
0~0
Command 05
0~0
Command 06
0~0
Command 20
0~7
States (Note 3)
Command 21
0~0
Command 22
0~0
Command 24
0~0
Command 25
0~0
Command 26
0~0
Command 27
0 ~ 31
Command 28
0 ~ 31
Command 84
0~0
Command 90
0~0
Command 91
1 ~ 14
Command 92
1 ~ 14
Command 93
0~0
Command 94
0~0
Command 9B
0~0
Parameter
hh
0 ~ 7F
Note:
1.
Command 84,Command 93,Command 94 and Command 9B are write only.(These commands are able to use Set
Bit Object and execute the write command after trigger Set Bit Object.). Except these four commands, others are
read only.
2.
Parameter read/write: Use Device type to define address control from 00~7F
For example: address_00 is mapping to Parameter_00. (Please refer detail with Panasonic
MINAS A4 series user manual.)
3.
4.
Command 91 and Command 92 are word type, use Operating range to map the record of 14 alarms.
For example: Command 91_1 means Read alarm data_First alarm.
Wiring diagram:
MT8000 RS232
9P D-SUB
MINAS A4 Driver
8p Mini-DIN Male CNX4
Port / RS232
COM1
COM2
COM3
3 TX
4 TX
7 TX
RXD
2 RX RRX 6 RX
8 RX
TXD
5 GND
5 GND
GND
5 GND
MT8000 RS485 2w
9P D-SUB
MINAS A4 Driver
8p Mini-DIN Male
MINAS A4 Driver
8p Mini-DIN Male
COM1
COM3
CNX3 Port/RS485 2w
CNX4 Port/RS485 2w
RX-
Data-
D-
D-
RX+
Data+
D+
D+
245
MINAS A4 Driver
CNX3 Port
8P Mini-Din Female
MINAS A4 Driver
CNX3 / CNX4 Port
D-
3 TX
D+
RX
GND
GND
D-
D+
MINAS A4 Driver
8p Mini-DIN Male
DD+
MINAS A4 Driver
CNX4 Port
7
8
GND
DD+
4
GND
MINAS A4 Driver
8p Mini-DIN Male
RXD
RXD
TXD
TXD
GND
GND
246
Driver Version:
Version
Date
V0.01
Jul/23/2009
Description of Changes
247
Parker Compax3
Parker Compax3 Servo Drive
http://www.parker.com
HMI Setting:
RS232
Parameters
Recommend
Option
Notes
PLC type
Com port
RS-232
Baud rate
115200
Parity bit
None
Data Bits
7 or 8
Stop Bits
1 or 2
Parameters
Recommend
Option
PLC type
Com port
RS-485 2W
Baud rate
9600
Parity bit
None
Data Bits
7 or 8
Stop Bits
1 or 2
1-99
RS485
Notes
Device address:
Bit/Word
B
B
DW
DW
W
Device Type
R_Low16bit
R_High16bit
Register_Int
Register_float
Register_Short
Format
dddddddd(h)
dddddddd(h)
dddddd
dddddd
dddddd
248
Range
0~99999999(f)
0~99999999(f)
0~999999
0~999999
0~999999
Memo
Wiring diagram:
RS232:
EasyView MT8000
RS232 9P D-SUB
COM1 [RS232]
COM2 [RS232]
COM3 [RS232]
X10
9P D-SUB
TX
TX
TX
RXD
RX
RX
RX
TXD
GND
GND
GND
GND
RS485:
EasyView MT8000
RS-485 2w D-SUB
Parkar Compax3 PLC
COM1[485]
COM3[485]
X10
9P D-SUB
RX-
Data-
RXD
RX+
Data+
TXD
GND
GND
GND
Enable RS485
+5V
249
Driver Version:
Version
Date
Description of Changes
V1.70
250
HMI Setting:
Parameters
Recommend
Option
Notes
PLC type
Com port
RS485 4w
Baud rate
9600
9600/19200
Parity bit
Even
Data Bits
7,8
Stop Bits
1,2
0-31
Online Simulator
YES
PLC Setting:
Communication mode
9600,Even,8,1
Device address:
Bit/Word
Device Type
Format
Par_Binary
DDD(DD)
Par_One_Word
Par_One_Byte
Range
Memo
0~4999(15)
DDD
0~4999
DDD
0~4999
251
Bit/Word
Device Type
Format
DW
Par_Two_Word
DDD
Range
Memo
0~4999
Wiring diagram:
Parker SLVD Servo
MT8000
COM1[RS-485]4w
Serial LINK X1
15P D-Sub
9P D-SUB
1
RX-
RX+
12
GND
GND
TX-
RX-
TX+
RX+
TER
TXTX+
Driver Version:
Version
Date
V1.00
Jan/28/2010
Description of Changes
252
HMI Setting:
Parameters
Recommend
Option
PLC type
Com port
RS232
RS232, RS485
Baud rate
9600
9600, 19200
Parity bit
Even
Data Bits
7,8
Stop Bits
Notes
PDS driver
0-255
PLC Setting:
Communication mode
9600,E,7,1(default)
Device address:
Bit/Word
Device Type
Format
Range
Flag
ddd
ddd=0~8191
Input
ddd
ddd=0~511
Output
ddd
ddd=0~511
Register
ddd
ddd=0~4095
Counter
ddd
ddd=0~1599
Timer
ddd
ddd=0~450
Reg_Float
ddd
ddd=0~4095
253
Memo
Wiring diagram:
RS232:
COM1
3
2
5
7
MT8000 RS232
9P D-SUB Male
9P D-SUB Female
COM2
COM3
TX
RX
GND
RTS
Driver Version:
Version
Date
V1.02
Dec/30/2008
Description of Changes
254
RXD
TXD
GND
DSR
RTS
CTS
HMI Setting:
Parameters
Recommend
PLC type
Option
SAIA PCD PGU mode
Notes
PDS driver
mode
Com port
RS232
RS232, RS485
Baud rate
9600
Parity bit
None
Data Bits
7,8
Stop Bits
0-255
PLC Setting:
Communication mode
9600,N,8,1(default)
RS232
Port 0-Type:RS232
RS485 2W
Device address:
Bit/Word
Device Type
Format
Range
Flag
ddd
ddd=0~8191
Input
ddd
ddd=0~511
Output
ddd
ddd=0~511
Register
ddd
ddd=0~4095
Counter
ddd
ddd=0~1599
Timer
ddd
ddd=0~450
Reg_Float
ddd
ddd=0~4095
255
Memo
Wiring diagram:
RS232:
MT8000 RS232
9P D-SUB Male
9P D-SUB Female
COM1
COM2
COM3
3 TX
2 RX
5 GND
4 TX
6 RX
5 GND
7 TX
8 RX
5 GND
RXD
TXD
GND
RTS
CTS
RS485:
MT8000 RS-485
SAIA PCD1
9P D-SUB Female
Port# 1
COM1
COM3
RX-
Data-
11
RX+
Data+
12
GND
GND
MT8000 RS-485
SAIA PCD1
9P D-SUB Female
Port# 0
COM1
COM3
RX-
Data-
29
RX+
Data+
28
GND
GND
Driver Version:
Version
Date
V1.10
Dec/30/2009
Description of Changes
256
Schleicher XCX20C
Schleicher XCx-Systems Ethernet port.
Schleicher XCS series, 20C model
http://www.schleicher-electronic.com
HMI Setting:
Parameters
Recommend
PLC type
Schleicher XCS20
Com port
RS232
Baud rate
38400
Parity bit
Data Bits
Stop Bits
Option
Notes
Device address:
Bit/Word
B
B
B
W
W
W
DW
DW
DW
Device
Type
IX
QX
MX
IW
QW
MW
Format
Range
Memo
ddddd(o)
ddddd(o)
ddddd(o)
ddddd
ddddd
ddddd
ID
QD
ddddd
ddddd
MD
ddddd
Input %IX
Output %QX
%MX
%IW
%QW
%MW
%ID
%QD
%WD
257
Wiring diagram:
Schleicher XCS20
RS-232 X1
9P D-SUB Male
MT8000 RS232
9P D-SUB Female
COM1
COM2
COM3
TX
TX
TX
RD
RX
RX
RX
TD
GND
GND
GND
GND
Driver Version:
Version
Date
V1.00
Nov/30/2009
Description of Changes
258
HMI Setting:
Parameters
Recommend
PLC type
Com port
Ethernet
Option
Notes
RS232,
RS422,
Ethernet
20547
PLC Setting:
Must create variable for HMI access.
Device address:
Bit/Word
B
B
B
W
W
W
DW
DW
DW
Device
Type
IX
QX
MX
IW
QW
MW
Format
Range
Memo
ddddd(o)
ddddd(o)
ddddd(o)
ddddd
ddddd
ddddd
ID
QD
ddddd
ddddd
MD
ddddd
Input %IX
Output %QX
%MX
%IW
%QW
%MW
%ID
%QD
%MD
Wiring diagram:
Ethernet: Direct connect (crossover cable)
MT8000 Ethernet
RJ45
Wire color
PLC
RJ45
TX+
White/Orange
RX+
TX-
Orange
RX-
RX+
White/Green
TX+
BD4+
Blue
BD4+
BD4-
White/Blue
BD4-
RX-
Green
TX-
BD3+
White/Brown
BD3+
BD3-
Brown
BD3-
Ethernet Hub:
MT8000 Ethernet
RJ45
Wire color
TX+
White/Orange
RX+
TX-
Orange
RX-
RX+
White/Green
TX+
BD4+
Blue
BD4+
BD4-
White/Blue
BD4-
RX-
Green
TX-
BD3+
White/Brown
BD3+
BD3-
Brown
BD3-
RS232 port
MT8000 RS-232
Schleicher xcx300
9P D-SUB
RS232 Port
COM1
COM2
COM3
TX
TX
TX
RXD
RX
RX
RX
TXD
GND
GND
GND
GND
260
8
RJ45
connector
RS422 port
MT8000
Schleicher xcx300
COM1 RS-485 4w
RS422 Port
RX-
TX-
RX+
TX+
TX-
RX-
TX+
RX+
GND
GND
Driver Version:
Version
Date
V1.00
Nov/30/2009
V1.10
Jul/1/2010
Description of Changes
261
HMI Setting:
Parameters
Recommend
Option
PLC type
Com port
RS-485
PLC Station
Notes
0~255
No.
Baud rate
9600
Data bit
Parity bit
Even
Stop bit
Device address:
Bit/Word
Device Type
Format
INDEX
DDDddddd
INDEX_Bit
DDDddddd(h)
Range
Memo
DDD(000~255)
D: Sub Index
ddddd(08000~25000)
d: Index
DDD(000~255)
D: Sub Index
ddddd(08000~25000)
h(0~f)
d: Index
h: Index_bit
The MOVITRAC-07 doesnt support Sub indexother series maybe support, please fixed to
input 000.
When input D and d, the correct format example as followSub index 15, Index 8359, Format
is 01508359
Wiring diagram:
EasyView MT8000
RS-485 2W (COM 1)
MOVITRAC-07
RS-485
262
Pin 1 ( )
Green
Pin 2 (D)
Red
Driver Version:
Version
Date
V1.20
Dec/30/2008
Description of Changes
263
HMI Setting:
1.
Parameters
Recommend
Option
PLC type
Com port
Ethernet
TCP port
102
Notes
2.
In S7-1200 program software creates PLC program and tag and then download to PLC.
Select Go offline, EB8000 will connect to PLC and get tag data.
In PLC type selectSIEMENS S7/1200 (Ethernet). Set Interval of block pack (words) to 0.
3.
264
4.
Check the PLC has not any PC connected. Click Get tag info, it will show a successful
message.
5.
265
266
EB8000
Data format
Memo
bit
16-bit BCD, Hex, Binary, Unsigned
16-bit BCD, Hex, Binary, Signed
32-bit BCD, Hex, Binary, Unsigned
32-bit BCD, Hex, Binary, Signed
32-bit Float
Word array for ASCII input and ASCII
display
Length=word
Wiring diagram:
Ethernet:
MT8000 Ethernet
RJ45
1
TX+
Wire color
Ethernet Hub or
Switch RJ45
1
White/Orange
RX+
RJ45 connector
2
TX-
Orange
RX-
RX+
White/Green
TX+
BD4+
Blue
BD4+
BD4-
White/Blue
BD4-
RX-
Green
TX-
BD3+
White/Brown
BD3+
BD3-
Brown
BD3-
Wire color
S7-1200 Ethernet
RJ45
TX+
White/Orange
RX+
TX-
Orange
RX-
RX+
White/Green
TX+
BD4+
Blue
BD4+
BD4-
White/Blue
BD4-
RX-
Green
TX-
BD3+
White/Brown
BD3+
BD3-
Brown
BD3-
267
Notification:
On-line Simulation
OK
Multi-PLC connect
OK
Driver Version:
Version
Date
Description of Changes
V1.00
268
SIEMENS S7/200
Siemens S7/200 series PLC (CPU212/214/215/216/221/222/224/226/226XM)
http://www.ad.siemens.com
HMI Setting:
Parameters
Recommend
PLC type
SIEMENS S7/200
Com port
RS485 2w
Option
Notes
RS485 2w
Must same as the PLC setting
The
Baud rate
9600
HMIs
which
has
sticker
Parity bit
Even
Data Bits
7,8
Stop Bits
1, 2
(ms)
Reserved 1
30
Online Simulator
YES
Broadcast command
NO
NO
PLC Setting:
Communication mode
Device address:
Bit/Word
Device Type
Format
Range
dddd(o)
0-40957
Input (I)
dddd(o)
0-40957
Output (O)
dddd(o)
0-40957
Bit Memory
VW.Bit
ddddd(o)
0-102397
VB
ddddd
0-10239
VW
ddddd
0-10239
269
Memo
V memory
VW_Odd
ddddd
0-10239
V memory
DW
VD
ddddd
0-10239
DW
VD_Odd
ddddd
0-10239
VD_String
ddddd
0-10239
String
VD_String_Odd
ddddd
0-10239
String
VW_String
ddddd
0-10239
String
VW_String_Odd
ddddd
0-10239
String
MB
ddddd
0-10239
byte memory
MW
ddddd
0-10239
Word memory
MW_Odd
ddddd
0-10239
Word memory
ddd
0-127
Timer
ddd
0-127
Counter
* Double word and Floating point value must use VD device type.
Wiring diagram:
MT8000 RS-485
9P D-SUB Female
SIEMENS S7/200
CPU Port
9P D-SUB Female
COM1
COM3
RX-
Data-
8 D-
RX+
Data+
3 D+
GND
GND
Driver Version:
Version
Date
V2.30
Aug/17/2009
Description of Changes
270
GND
HMI Setting:
Parameters
Recommend
PLC type
Siemens S7/200
Option
Notes
(Ethernet)
Com port
Ethernet
Port no.
102
0-31
Device address:
Bit/Word
Device Type
Format
Range
Memo
dddd(o)
0-40957
Input (I)
dddd(o)
0-40957
Output (O)
dddd(o)
0-40957
Bit Memory
VW.Bit
ddddd(o)
0-102397
VW
ddddd
0-10239
V memory
VW_String
ddddd
0-10239
String
DW
VD
ddddd
0-10239
DW
VD_String
ddddd
0-10239
String
Double word and Floating point value must use VD device type.
Wiring diagram:
MT8000 Ethernet
Wire color
White/Orang
Orange
White/Green
Blue
White/Blue
Green
White/Brow
Brown
1
2
3
4
5
6
7
8
RJ45
1 TX+
2 TX3 RX+
4 BD4+
5 BD46 RX7 BD3+
8 BD3-
271
RX+
RXTX+
BD4+
BD4TXBD3+
BD3-
RJ45 connector
Ethernet: Direct connect (crossover cable)
MT8000 Ethernet Wire color
Ethernet Device
RJ45
RJ45
1
2
3
TX+
TXRX+
White/Orange
Orange
White/Green
3
6
1
RX+
RXTX+
4
5
6
7
8
BD4+
BD4RXBD3+
BD3-
Blue
White/Blue
Green
White/Brown
Brown
4
5
2
7
8
BD4+
BD4TXBD3+
BD3-
Driver Version:
Version
Date
V1.20
Dec/30/2008
Description of Changes
272
SIEMENS S7/300
Siemens S7/300 series PLC
http://www.ad.siemens.com
HMI Setting:
Parameters
Recommend
PLC type
SIEMENS S7/300
Com port
RS232
Option
Notes
19200, 38400,
Baud rate
187.5K
9600~187.5K
on the rear panel, support 187.5 baud
rate.
Parity bit
Odd
Data Bits
Stop Bits
PLC Setting:
Communication mode
Device address:
Bit/Word
Device Type
Format
Range
dddd(o)
0-40957
Input (I)
dddd(o)
0-40957
Output (O)
dddd(o)
0-40957
Bit Memory
DB0Bit-DB99Bit
dddd(o)
0-81927
DB0-DB99
dddd
0-8192
IW
dddd
0-4095
Input (I)
QW
dddd
0-4095
Output (O)
MW
dddd
0-4095
Bit Memory
DBn
dddddd
000000-998192
DBDn
fffdddd
ff:0-255, dddd:0-8192
DW
Memo
* Double word and Floating point value must use DBDn device type.
273
Wiring diagram:
MT8000 RS232
SIEMENS S7/300 PC
9P D-SUB Male
COM1
COM2
COM3
3 TX
2 RX
5 GND
4 TX
6 RX
5 GND
7 TX
8 RX
5 GND
9P D-SUB Male
2
RXD
TXD
GND
RTS
CTS
MT8000 RS232
Systeme Helmholz
9P D-SUB Male
SSW7-TS
COM1
COM2
COM3
3 TX
2 RX
5 GND
4 TX
6 RX
5 GND
7 TX
8 RX
5 GND
9P D-SUB Male
Driver Version:
Version
Date
V2.60
Jul/08/2009
V2.70
Nov/16/2009
Description of Changes
274
RXD
TXD
GND
RTS
CTS
DTR
DSR
HMI Setting:
Parameters
Recommend
PLC type
Siemens S7/300
Option
Notes
(Ethernet)
Com port
Ethernet
Port no.
102
0-31
Device address:
Bit/Word
Device Type
Format
Range
dddd(o)
0-40957
Input (I)
dddd(o)
0-40957
Output (O)
dddd(o)
0-40957
Bit Memory
DB0Bit-DB99Bit
dddd(o)
0-81927
DB0-DB99
dddd
0-8192
IW
dddd
0-4095
Input (I)
QW
dddd
0-4095
Output (O)
MW
dddd
0-4095
Bit Memory
DBn
dddddd
000000-998192
DBDn
fffdddd
fff:0-250, dddd:0-8192
DW
Memo
* Double word and Floating point value must use DBDn device type.
275
Wiring diagram:
MT8000 Ethernet
Wire color
White/Orang
Orange
White/Green
Blue
White/Blue
Green
White/Brow
Brown
1
2
3
4
5
6
7
8
RJ45
1
2
3
4
5
6
7
8
TX+
TXRX+
BD4+
BD4RXBD3+
BD3-
RX+
RXTX+
BD4+
BD4TXBD3+
BD3-
RJ45 connector
Wire color
Ethernet Device
RJ45
RJ45
1
2
3
TX+
TXRX+
White/Orange
Orange
White/Green
3
6
1
RX+
RXTX+
4
5
6
7
8
BD4+
BD4RXBD3+
BD3-
Blue
White/Blue
Green
White/Brown
Brown
4
5
2
7
8
BD4+
BD4TXBD3+
BD3-
Driver Version:
Version
Date
Description of Changes
V1.60
Jul/09/2009
V1.70
Nov/16/2009
276
HMI Setting:
Parameters
Recommend
Option
PLC type
Com port
RS485 2w
Baud rate
187.5K
Parity bit
Even
Data Bits
Stop Bits
Notes
Device address:
Bit/Word
Device Type
Format
Range
dddd(o)
0-40957
Input (I)
dddd(o)
0-40957
Output (O)
dddd(o)
0-40957
Bit Memory
DB0Bit-DB99Bit
dddd(o)
0-81927
DB0-DB99
dddd
0-8192
IW
dddd
0-4095
Input (I)
QW
dddd
0-4095
Output (O)
MW
dddd
0-4095
Bit Memory
DBn
dddddd
000000-998192
DW
DBDn
ffdddd
ff:0-99, dddd:0-8192
* Double word and Floating point value must use DBDn PLC device type.
277
Memo
Wiring diagram:
MT8000iV series HMI
COM1
COM3
RX-
Data-
RX+
Data+
3 D+
GND
GND
Driver Version:
Version
Date
V1.10
Jul/09/2009
V1.20
Nov/16/2009
Description of Changes
278
D-
GND
SIMATIC TI505
SIMATIC TI505 Series PLCs: TI520, TI525, TI530, TI535, TI545, TI555, TI560, TI565, TI575
Using the NITP protocol in a point-to-point single master, single slave format.
http://www.ad.siemens.de/simatic/controller/index_76.htm
HMI Setting:
Parameters
Recommend
Option
PLC type
SIMATIC TI505
Com port
RS232
RS232, RS485(4W)
Baud rate
19200
19200
Parity bit
Odd
Odd
Data Bits
Stop Bits
Notes
PLC Setting:
Communication mode
NITP protocol
Device address:
Bit/Word
Device Type
Format
Range
CR
ddddd
ddddd:1~65535
Internal Relay
ddddd
ddddd:1~65535
ddddd
ddddd:1~65535
ddddd
ddddd:1~65535
STW
ddddd
ddddd:1~65535
TCP
ddddd
ddddd:1~65535
TCC
ddddd
ddddd:1~65535
WX
ddddd
ddddd:1~65535
WY
ddddd
ddddd:1~65535
279
Memo
Wiring diagram:
RS-232:
MT8000 HMI
9P D-SUB
SIMATIC TI505
25Pin D-SUB
TX
RX
GND
4 TX
6 RX
5 GND
7 TX
8 RX
5 GND
3 RXD
2 TXD
7 GND
4 RTS
5 CTS
6 DSR
8 DCD
20 DTR
RS-232:
MT8000 HMI
SIMATIC TI505
9Pin D-SUB
9P D-SUB
COM1 [RS232] COM2 [RS232] COM3 [RS232]
3
2
5
TX
RX
GND
4 TX
6 RX
5 GND
7 TX
8 RX
5 GND
2 RXD
3 TXD
5 GND
7 RTS
8 CTS
1 DCD
4 DTR
6 DSR
RS485 4W:
MT8000HMI
SIMATIC TI505
9Pin D-SUB
COM1 RS-485/4w
9P D-SUB
1
RX-
DO(-)
RX+
DO(+)
TX-
DI(-)
TX+
DI(+)
GND
GND
280
Driver Version:
Version
Date
V1.10
Apr/22/2009
Description of Changes
281
HMI Setting:
Parameters
Recommend
Option
PLC type
Taian TP02
Com port
RS485 4W/2W
RS485 4W/2W
Notes
Baud rate
19200
Parity bit
Even
Data Bits
7, 8
Stop Bits
1, 2
0-255
PLC Setting:
RS422 port:WS041=120,WS042=1;
RS485 terminals:WS044=120,WS045=1.
Device address:
Bit/Word
Device Type
Format
Range
Memo
ddd
1~384
Input relay
ddd
1~384
Output relay
dddd
1~2048
Auxiliary relay
ddd
ddd
dddd
1~1024
Auxiliary register
dddd
1~2048
Auxiliary register
WS
ddd
1~128
System register
dddd
WC
ddd
1-369 (must be 1 or a
multiple of plus 1)
1-369 (must be 1 or a
multiple of plus 1)
1-2033 (must be 1 or a
multiple of plus 1)
1~912
282
Input register
Output register
Auxiliary relay
register
Constant register
Wiring diagram:
TP02 Series MMI RS422 port
MT8000 RS-485 4w
9P D-SUB
1
2
3
4
RXRX+
TXTX+
TXTX+
RXRX+
9P D-SUB
RS485 Terminals
1
2
RXRX+
T/RT/R+
Driver Version:
Version
Date
V1.10
Jan/25/2010
Description of Changes
283
HMI Setting:
Parameters
Recommend
Option
PLC type
Com port
RS485 4w
Baud rate
19200
9600, 19200
Parity bit
None
Data Bits
Stop Bits
1-31
Notes
Device address:
Bit/Word
Device Type
Format
Range
B
B
C
M
dddd
dddd
0 ~ 9999
0 ~ 9999
dddd
0 ~ 9999
dddd
ooo
0 ~ 9999
0 ~ 377
B
W
ooo
0 ~ 377
dddd
0 ~ 9999
dddd
0 ~ 9999
dddd
0 ~ 9999
T_Curent
dddd
0 ~ 9999
C_Curent
dddd
0 ~ 9999
T_Preset
dddd
0 ~ 9999
C_Preset
dddd
0 ~ 9999
284
Memo
Wiring diagram:
MT8000 RS-485 4w
9P D-SUB
1
2
5
3
4
RXRX+
GND
TXTX+
4
7
3
1
2
TXTX+
GND
RXRX+
Driver Version:
Version
Date
V1.00
Apr/22/2009
Description of Changes
285
8 Pin mini
DIN Female
Telemecanique UniTelWay
Modicon TSX Micro&Nano&Neza series PLC
http://www.modicon.com
HMI Setting:
Parameters
Recommend
PLC type
Telemecanique
Option
Notes
UniTelWay
Com port
RS485
RS232/RS485
Baud rate
9600
9600~115200
Parity bit
Odd
Data Bits
7,8
Stop Bits
1, 2
4-7
0-3
Online Simulator
YES
Broadcast command
NO
YES
PLC Setting:
Communication mode
Device address:
Bit/Word
Device Type
Format
Range
ddd
0-32767
Internal relay
ddd
0-32767
Auxiliary relay
MW.B
ddd(dd)
0-999915
MW
ddd
0-9999
286
Memo
Data register
Wiring diagram:
TSX37-XX/TSX07-XX CPU
MT8000 RS-485
9P D-SUB
8P mini-din Female
COM1
COM3
RX-
Data-
2 D-
RX+
Data+
1 D+
GND
GND
7 GND
Driver Version:
Version
Date
V1.20
Sep/24/2009
Description of Changes
287
TECO Inverter
TECO Inverter series, 7300CV model
HMI Setting:
Parameters
Recommend
PLC type
TECO Inverter
Com port
RS232
Baud rate
38400
Parity bit
None
Data Bits
Stop Bits
Option
Notes
RS232/RS485
Device address:
Bit/Word
B
B
B
Device Type
0x
1x
3x_Bit
Format
ddddd
ddddd
ddddd(dd)
4x_Bit
ddddd(dd)
B
W
W
DW
W
0x (0x0f)
3x
4x
5x
6x
ddddd
ddddd
ddddd
ddddd
ddddd
Range
1-65535
1-65535
100-6553515
100-6553515
Memo
Output bit
Input bit (read only)
Input Register bit (read only)
1-65535
1-65535
1-65535
1-65535
1-65535
288
Wiring diagram:
MT8000 RS-232
TECO Inverter
9P D-SUB
RS232
COM1
3
TX
RX
RX
AX
GND
GND
RTS
VCC
Driver Version:
Version
Date
V1.00
Jul/27/2009
Description of Changes
289
TOSHIBA T series
Toshiba T series, S2E
http://www.tic.toshiba.com
HMI Setting:
Parameters
Recommend
PLC type
Toshiba T Serial
Com port
RS232
RS232/RS485
Baud rate
9600
9600, 19200,38400,57600,115200
Parity bit
Odd
Data Bits
7,8
Stop Bits
1, 2
0-255
0-255
Online Simulator
Option
YES
Notes
YES
Broadcast command
PLC Setting:
Communication mode
Device address:
Bit/Word
Device Type
Format
Range
ddd(h)
0-9999f
Input Bit
ddd(h)
0-9999f
Output Bit
ddd(h)
0-9999f
Auxiliary Bit
ddd(h)
0-9999f
Special Bit
ddd
0-9999
Timer Register
ddd
0-9999
Counter Register
ddd
0-9999
Data Memory
SW
ddd
0-9999
Special Register
XW
ddd
0-9999
Input Register
YW
ddd
0-9999
Output Register
RW
ddd
0-9999
Auxiliary Register
290
Memo
Wiring diagram:
RS232
MT8000 RS232
9P D-SUB
8P mini-D
COM1
3
2
5
COM2
TX
RX
GND
4 TX
6 RX
5 GND
RXD
TXD
GND
RTS
CTS
9P D-SUB
9P D-SUB Female
4 TX
6 RX
5 GND
COM3
7 TX
8 RX
5 GND
RS485
MT8000 COM1
RS485
9P D-SUB
1
RX-
11
TXB
RX+
TXA
TX-
10
RXB
TX+
RXA
GND
SG
RTSA
CTSA
13
RTSB
12
CTSB
Driver Version:
Version
COM2
TX
RX
GND
7 TX
8 RX
5 GND
MT8000 RS232
COM1
3
2
5
COM3
Date
Description of Changes
291
RXD
TXD
GND
RTS
CTS
V1.00
Sep/15/2009
HMI Setting:
Parameters
Recommend
Option
Notes
PLC type
Provisor TC200
Provisor TC200
Com port
RS232
RS232
Baud rate
9600
9600, 19200
Parity bit
None
Data Bits
7,8
Stop Bits
1, 2
Device address:
Bit/Word
Device Type
Format
Range
Memo
X_Bit
hhh(h)
0-fff(f)
Y_Bit
hhh(h)
0-fff(f)
R_Bit
hhh(h)
0-fff(f)
L_Bit
hhh(h)
0-fff(f)
hhh
0-fff
hhh
0-fff
hhh
0-fff
hhh
0-fff
hhh
0-fff
292
Wiring diagram:
RS232
MT8000 HMI
RS232 9P D-SUB
COM1
TC mini series
9P D-SUB
COM2
COM3
TX
TX
TX
RXD
RX
RX
RX
TXD
5 GND
GND
RTS
CTS
5 GND
5 GND
Driver Version:
Version
Date
Description of Changes
293
TOSHIBA VF-S11
Toshiba Invertor Protocol(ASCII code)
HMI Setting:
Parameters
Recommend
PLC type
Toshiba VF-S11
Com port
RS485(2 wire)
RS422, RS485
Baud rate
9600
9600, 19200
Parity bit
Even
Data Bits
7 or 8
Stop Bits
1 or 2
Online Simulator
YES
Broadcast command
YES
Option
Notes
0-99
YES
PLC Setting:
Communication mode
Device address:
Bit/Word
Device Type
Format
Range
Memo
Word
Communication No.
HHH
HHH:0~ 0FFF
Bit
Comm.No.Bit
HHH(DD)
HHH(DD):0-FFF(15)
294
Wiring diagram:
Pay Attention:
Before you connect the VF-S11, make sure you to put both switches of SW1 to the related position. (SW1:
Wiring method selector switch)
RS-485
MT8000 RS-485
TOSHIBA
9P D-SUB
VFFS1-VFPS1
COM1
RJ45
COM3
RX-
Data-
RX+
Data+
GND
GND
295
Driver Version:
Version
Date
V1.20
Aug/31/2009
Description of Changes
296
VIGOR
VIGOR M Series
http://www.vigorplc.com.tw/
HMI Setting:
Parameters
Recommend
PLC type
VIGOR
Com port
RS232
Baud rate
19200
Parity bit
Even
Data Bits
Stop Bits
Option
Notes
PLC Setting:
Communication mode
None
Device address:
Bit/Word
Device Type
Format
Range
ooo
0~177
ooo
0~177
dddd
0~4095
ddd
0~999
ddd
0~255
ddd
0~255
TV
ddd
0~255
CV
ddd
0~255
dddd
0~4095
DL
dddd
0~4095
297
Memo
Double word
Wiring diagram:
RS-485 4wire:
MT8000
VIGOR M series
COM1 RS485 4w
6pin terminal
9P D-SUB Male
1
RX-
TX-
RX+
TX+
TX-
RX-
TX+
RX+
GND
SG
24V
RS-232:
VIGOR M series
COM Port
MT8000 RS232
9P D-SUB
COM1
3
2
5
TX
RX
GND
COM2
4 TX
6 RX
5 GND
COM3
7 TX
8 RX
5 GND
Driver Version:
Version
Date
V1.00
Dec/30/2008
Description of Changes
298
RXD
TXD
GND
YASGAWA SMC3010
YASKAWA SMC Series Servo Motor Controller
HMI Setting:
Parameters
Recommend
Device type
Com port
RS232
Baud rate
19200
Parity bit
None
Data Bits
Stop Bits
Option
Notes
9600, 19200
Device address:
Bit/Word
Device Type
Format
Range
Memo
AF
0~1
BN
0~1
Write only
BP
0~1
Write only
BV
0~1
Write only
CB
dddd
0 ~ 9999
Write only
CM
0~1
Read only
DV
0~1
EB
0~1
OE
0~1
RS
0~1
Write only
ST
0~1
Write only
TB
0~1
Read only
V_bit
DDDdd
DDD:0~999, dd:0~31
*2
DW
AC
0~4
DW
DC
0~4
DW
BL
0~4
CD
0~2
CE
0~2
DW
DE
0~4
DW
DP
0~4
DT
0~2
Write only
299
Bit/Word
Device Type
Format
Range
Memo
EC
0~2
DW
EM
0~4
ER
0~2
FA
0~2
DW
FL
0~4
FV
0~2
DW
GR
0~4
DW
JG
0~4
DW
MM
0~4
MT
0~2
NA
0~2
OP
0~2
DW
PA
0~4
DW
PR
0~4
DW
SP
0~4
TC
0~2
TM
0~2
TW
0~2
DW
VA
0~4
DW
VD
0~4
DW
VS
0~4
DW
IL
0~4
DW
IT
0~4
DW
KD
0~4
DW
KI
0~4
DW
KP
0~4
DW
OF
0~4
DW
TL
0~4
DW
VR
0~4
DW
VT
0~4
DW
PF
0~4
DW
VF
0~4
DW
DDD
0 ~ 999
*2
DDD
0 ~ 999
*2
Write only
Read only
*1
Note:
*1 PF is the communication parameter of SMC_3010, default is 10.4, if the value is not 10.4, all
values will be displayed incorrect.
300
Wiring diagram:
MT8000 RS232
9P D-SUB
COM1
COM2
COM3
TX
TX
TX
RXD
RX
RX
RX
TXD
GND
GND
GND
GND
RTS
CTS
Driver Version:
Version
Date
V1.2.0
Feb/10/2010
Description of Changes
301
HMI Setting:
Parameters
Recommend
Option
Device type
Com port
Ethernet
Notes
Port:23
Baud rate
Parity bit
Data Bits
Stop Bits
Device address:
Bit/Word
Device Type
Format
Range
Memo
AF
0~1
BN
0~1
Write only
BP
0~1
Write only
BV
0~1
Write only
CB
dddd
0 ~ 9999
Write only
CM
0~1
Read only
DV
0~1
EB
0~1
OE
0~1
RS
0~1
Write only
ST
0~1
Write only
TB
0~1
Read only
V_bit
DDDdd
DDD:0~999, dd:0~31
DW
AC
0~4
DW
DC
0~4
DW
BL
0~4
CD
0~2
CE
0~2
DW
DE
0~4
DW
DP
0~4
DT
0~2
302
*2
Write only
Bit/Word
Device Type
Format
EC
Range
Memo
0~2
DW
EM
0~4
ER
0~2
FA
0~2
DW
FL
0~4
FV
0~2
DW
GR
0~4
DW
JG
0~4
DW
MM
0~4
MT
0~2
NA
0~2
OP
0~2
DW
PA
0~4
DW
PR
0~4
DW
SP
0~4
TC
0~2
TM
0~2
TW
0~2
DW
VA
0~4
DW
VD
0~4
DW
VS
0~4
DW
IL
0~4
DW
IT
0~4
DW
KD
0~4
DW
KI
0~4
DW
KP
0~4
DW
OF
0~4
DW
TL
0~4
DW
VR
0~4
DW
VT
0~4
DW
PF
0~4
DW
VF
0~4
DW
DDD
0 ~ 999
*2
DDD
0 ~ 999
*2
Write only
Read only
*1
Note:
*1 PF is the communication parameter of SMC_3010, default is 10.4, if the value is not 10.4, all
values will be displayed incorrect.
303
Wiring diagram:
Ethernet:
MT8000 Ethernet
RJ45
Wire color
1
2
3
TX+
TXRX+
White/Orange
Orange
White/Green
1
2
3
RX+
RXTX+
4
5
6
7
8
BD4+
BD4RXBD3+
BD3-
Blue
White/Blue
Green
White/Brown
Brown
4
5
6
7
8
BD4+
BD4TXBD3+
BD3-
Wire color
1
2
3
TX+
TXRX+
White/Orange
Orange
White/Green
3
6
1
RX+
RXTX+
4
5
6
7
8
BD4+
BD4RXBD3+
BD3-
Blue
White/Blue
Green
White/Brown
Brown
4
5
2
7
8
BD4+
BD4TXBD3+
BD3-
Driver Version:
Version
Date
V1.0.0
Feb/22/2010
Description of Changes
304
8
RJ45
connector
YAMAHA ERCD
HMI Setting:
Parameters
Recommend
Option
Notes
PLC type
YAMAHA ERCD
Com port
RS232
Data Bits
7 or 8
Stop Bits
1 or 2
Baud rate
9600
1200-19200
Parity bit
Odd
None/Even/Odd
PLC station
No.
Device address:
Bit/Word
Device type
Range
Format
Memo
Word
ddd
0-999
Word
SWI
ddd
Switches program
number to be run
Word
ORG
ddd
Word
Reset
ddd
Word
RUN
ddd
Word
MOVD
ddd
specified position
RW1=X-axis position(mm),
RW2=speed
Word
X_ADD
ddd
Word
X_SUB
ddd
Write only X
305
command
Wiring diagram:
MT8000 RS232
PB
9P D-SUB
RS232
COM1
3 TX
2 RX
5 GND
3 TX
2 RX
5 GND
7 RTS
8 CTS
Driver Version:
Version
Date
V1.10
Aug/08/2009
Description of Changes
306
Yokogawa FA-M3
FA-M3 CPU SP35-5N, SP55-5N CPU port, F3LC11 Computer Link module.
http://www.yokogawa.com/itc/itc-index-en.htm
HMI Setting:
Parameters
Recommend
Option
PLC type
Yokogawa FA-M3
Com port
RS232
Baud rate
19200
9600, 19200
Parity Bit
Even
Data Bits
Stop Bits
Notes
1-31
PLC Setting:
Communication mode
Device address:
Bit/Word
Device Type
Format
Range
ddd
201-71664(discontinuous)
ddd
201-71664(discontinuous)
ddd
1-16384
ddd
1-71024(discontinuous)
ddd
1-9984
ddd
1-8192
ddd
1-32768
ddd
1-64
ddd
1-71024(discontinuous)
ddd
1-512
307
Memo
Wiring diagram:
RS-232: CPU port
MT8000 RS232
9P D-SUB
KM11 RS-232
MT8000 RS232
9P D-SUB
COM1
3
2
5
TX
RX
GND
COM2
4 TX
6 RX
5 GND
COM3
7 TX
8 RX
5 GND
RXD
TXD
GND
RS-232: LC11
MT8000 RS232
LC11 Computer
9P D-SUB Female
COM1
3
2
5
TX
RX
GND
COM2
4 TX
6 RX
5 GND
COM3
7 TX
8 RX
5 GND
RXD
TXD
GND
RTS
CTS
308
P.S Because use Personal computer link, when you connecting to PLC it will delay about 20sec for
test communication.
309
310
311
Driver Version:
Version
Date
V1.10
Jan/01/2009
Description of Changes
312
HMI Setting:
Parameters
PLC type
Com port
TCP port no.
HMI Station No.
PLC Station No.
Recommend
Yokogawa FA-M3
(Ethernet)
Ethernet
12289
0
1
Option
PLC Setting:
Communication mode
Set IP Address
Set all condition setup switch OFF.
313
Notes
Device address:
Bit/Word
Device Type
Format
Range
Memo
ddd
201-71664(discontinuous)
ddd
201-71664(discontinuous)
ddd
1-16384
ddd
1-71024(discontinuous)
ddd
1-9984
ddd
1-8192
ddd
1-32768
ddd
1-64
ddd
1-71024(discontinuous)
ddd
1-512
Wiring diagram:
Ethernet:
MT8000 Ethernet
Wire color
RJ45
RJ45
TX+
White/Orange
RX+
TX-
Orange
RX-
RX+
White/Green
TX+
BD4+
Blue
BD4+
BD4-
White/Blue
BD4-
RX-
Green
TX-
BD3+
White/Brown
BD3+
BD3-
Brown
BD3-
Wire color
RJ45
RJ45
TX+
White/Orange
RX+
TX-
Orange
RX-
RX+
White/Green
TX+
BD4+
Blue
BD4+
BD4-
White/Blue
BD4-
RX-
Green
TX-
BD3+
White/Brown
BD3+
BD3-
Brown
BD3-
314
RJ45
connector
Driver Version:
Version
Date
V1.00
Dec/30/2008
Description of Changes
315
Bottom View
MT6050i
Pin assignment of the 9 Pin, Male,
Pin assignment of the 9 Pin, Male, SUB-D, COM1 [RS-232]/ [RS-485], COM3 [RS-485] Port. Only
Com1[RS485 2W] support MPI 187.5K.
Pin#
Symbol
Com1[RS485]
4 wire
2 wire
Com1[RS232]
Com3[RS485]
Rx-
Rx-
Data-
Rx+
Rx+
Data+
Tx-
Tx-
Tx+
Tx+
GND
GND
TxD
Transmit
Data-
Data-
Data+
Data+
RxD
Receive
316
Wiring diagram:
MT6050i COM1 [RS-232]
PLC RS-232
9P D-SUB Female
RXD
TXD
TXD
RXD
GND
GND
PLC RS-485 2w
9P D-SUB Female
Data-
Data-
Data+
Data+
PLC RS-485 2w
9P D-SUB Female
Data-
Data-
Data+
Data+
PLC RS-485 2w
9P D-SUB Female
RX-
TX-
RX
TX+
TX-
RX-
TX+
RX+
317