0% found this document useful (0 votes)
16 views12 pages

Load Subcell Handover: Confidential Information

This document discusses parameters related to load balancing and handover between cells. It describes evaluating cell load periodically, thresholds for when the load is considered overloaded, and parameters to configure the load handover step period and zone. The parameters control whether uplink to overlay handovers are allowed, cell load thresholds, load handover period duration, adjusting handover margins, and thresholds for handover to incoming overlay subcells.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
16 views12 pages

Load Subcell Handover: Confidential Information

This document discusses parameters related to load balancing and handover between cells. It describes evaluating cell load periodically, thresholds for when the load is considered overloaded, and parameters to configure the load handover step period and zone. The parameters control whether uplink to overlay handovers are allowed, cell load thresholds, load handover period duration, adjusting handover margins, and thresholds for handover to incoming overlay subcells.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
You are on page 1/ 12

Load Subcell

Handover

Confidential Information
Confidential Information 2
Evaluate Cell Load periodically.
Checks for cell load periodically every 1
sec.

Confidential Information 3
UL to OL HO Allowed
Parameter ID= UTOOTRAFHOALLO
Value Range: Yes or No



Confidential Information 4
Cell load > out cell overlaid general
threshold
Parameter ID= ENGOVERLDTHRSH
Value Range: 0 ~ 100
Recommended Value =70



Confidential Information 5
Cell load > out cell overlaid Serious
threshold
Parameter ID= ENSOVERLDTHRSH
Value Range: 0 ~ 100
Recommended Value =80



Confidential Information 6
Configure load handover step period
equal to step value
Parameter ID= UTRAFHOPERIOD
Value Range: 1~ 255
Recommended Value =5
Unit = sec



Confidential Information 7
For Adaption value of load handover
step period duration by MOD Step
LEN of UL Load HO Period
Parameter Name = load HO Step Period
Parameter ID= UTRAFHOPERIOD
Value Range: 1~ 255
Recommended Value =5
Unit = sec

Parameter Name = MOD Len Of UL LOAD HO
Period
Value Range: 1~ 255
Recommended Value =1
Unit = sec




Confidential Information 8
Adjust HO Margin
HO Zone depends upon HO step level
and HO step period.
Parameter Name = load HO Step Period
Parameter ID= UTRAFHOPERIOD
Value Range: 1~ 255
Recommended Value =5
Unit = sec

Parameter Name = Underlay HO Step Level
Value Range: 1~ 63
Unit = db

Parameter name: Incoming OL Subcell HO Level
Threshold
Value Range: 0 - 63
Unit DB
Recommended value : 30






Confidential Information 9
Confidential Information 10
Confidential Information 11
Confidential Information 12

You might also like