Aeco Systems: Palo Alto, CA Studio 5 & Studio 6 - Wellesley Site

This document provides a parts list and device quantities for the fire alarm system of an E.V. Infill Graduate Student Housing project at Stanford University. It includes a table listing each fire alarm device type with the manufacturer, model number, quantity used, and applicable testing standards. It also provides notes on installation requirements for the fire alarm system wiring and devices.

Uploaded by

Lazado Bun
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
99 views1 page

Aeco Systems: Palo Alto, CA Studio 5 & Studio 6 - Wellesley Site

This document provides a parts list and device quantities for the fire alarm system of an E.V. Infill Graduate Student Housing project at Stanford University. It includes a table listing each fire alarm device type with the manufacturer, model number, quantity used, and applicable testing standards. It also provides notes on installation requirements for the fire alarm system wiring and devices.

Uploaded by

Lazado Bun
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Sheet Number

STANFORD UNIVERSITY
AECO
SYSTEMS
(510) 342-0008
Hayward, CA 94545
28302 Industrial Blvd - Suite A
FAX (510) 342-0013
FIRE ALARM
SYSTEM
Drawn By:
Date:
Scale:
Job No:
A. EBY REVISION DATE DESCRIPTION
STANFORD UNIVERSITY
11/07/01
50090
-
E.V. INFILL GRADUATE STUDENT HOUSING
Palo Alto, CA Studio 5 & Studio 6 - Wellesley Site
FA0.0-5
NONE
STUDIO 5 & 6
PROJECT INFORMATION
Studio 5 Commons Studio 6
Symbol Description Model Number Manufacturer G 2 3 4 A G 2 3 4 A Total CSFM Listing # Backbox
Fire Alarm Control Panel AFP-400 Notifier 1 0 0 0 0 0 1 0 0 0 0 2 7165-0028:181 custom
-- Relay Module ACM-8R Notifier 2 0 0 0 0 0 2 0 0 0 0 4 7120-0028:156 mounts in FACP cabinet
-- Battery, 25 AH PS12250 PowerSonic 2 0 0 0 0 0 2 0 0 0 0 4 -- --
Remote Annunciator LCD-80 Notifier 1 0 0 0 0 0 1 0 0 0 0 2 7120-0028:156 custom
Manual Pull Station NBG-12LX Notifier 8 4 4 4 1 6 8 4 4 4 1 4 8 7150-0028:199 4" sq x 1-1/2" deep with 1 gang ring
Stand Alone Smoke Detector 4120B BRK 30 36 38 39 0 0 30 36 38 39 0 286 -- --
Smoke Detector FSP-751 Notifier 23 22 21 21 2 6 23 22 21 21 2 184 7272-0028:206 B710LP Base
Smoke Detector w/sounder base FSP-751 Notifier 8 4 4 4 0 0 8 4 4 4 0 4 0 7272-0028:206 B501BH Sounder Base
Heat Detector FST-751R Notifier 1 0 0 0 1 1 1 0 0 0 1 5 7270-0028:196 B710LP Base
-- Detector Base B710LP Notifier 24 22 21 21 3 7 24 22 21 21 3 189 7300-0029:173 4" sq x 1-1/2" deep with 3/0 ring
-- Detector Sounder Base B501BH Notifier 8 4 4 4 0 0 8 4 4 4 0 4 0 7300-1209:128 4" sq x 2-1/8" deep box
Duct Smoke Detector FSD-751RP Notifier 0 0 0 0 4 0 0 0 0 0 4 8 3240-0218:205 --
Fire Smoke Damper F.B.O. -- 4 4 4 4 0 0 4 4 4 4 0 3 2 -- --
Waterflow Switch F.B.O. w/ FMM-101 -- 4 3 3 3 0 2 4 3 3 3 0 2 8 -- --
Valve Tamper Switch F.B.O. w/ FMM-101 -- 4 3 3 3 0 2 4 3 3 3 0 2 8 -- --
Sprinkler PIV Switch F.B.O. w/ FMM-101 -- 1 0 0 0 0 0 1 0 0 0 0 2 -- --
Monitor Module FMM-101 Notifier 16 8 7 7 0 4 16 8 7 7 0 8 0 7300-0028:202 mounts in box of device being monitored
Control Module FCM-1 Notifier 10 5 5 6 0 2 10 5 5 6 0 5 4 7300-0028:202 4" sq x 1-1/2" deep box
Control Relay FRM-1 Notifier 8 0 0 0 4 0 8 0 0 0 4 2 4 7300-0028:202 4" sq x 1-1/2" deep box
Control Relay MR-101/C Air Products 7 0 0 0 4 0 7 0 0 0 4 2 2 7300-1004:101 custom
End of Line Relay A77-716B System Sensor 4 1 1 1 0 0 4 1 1 1 0 1 4 7300-1209:161 mounts in box of device being monitored
Aux Power Supply FCPS-24 Notifier 2 2 2 3 0 1 2 2 2 3 0 1 9 7315-0028:178 custom
-- Battery, 7 AH PS1270 PowerSonic 4 4 4 6 0 2 4 4 4 6 0 3 8 -- --
Dual Sync Module DSM Wheelock 4 4 4 6 0 0 4 4 4 6 0 3 6 7300-0785:132 4-11/16" sq x 2-1/8" deep box
Horn Strobe, 15 candela NS4-24MCW-FW Wheelock 10 9 9 8 7 0 10 9 9 8 7 8 6 7125-0785:142 4" sq x 1-1/2" deep with 1 gang ring
Horn Strobe, 110 candela NS4-24MCW-FW Wheelock 11 6 6 6 1 4 11 6 6 6 1 6 4 7125-0785:142 4" sq x 1-1/2" deep with 1 gang ring
Horn NH-24 Wheelock 30 36 38 39 0 0 30 36 38 39 0 286 7125-0785:142 4" sq x 1-1/2" deep with 1 gang ring
Horn, Weather Proof AH-24WP-R Wheelock 5 0 0 0 0 3 5 0 0 0 0 1 3 7125-0785:131 4" sq x 1-1/2" deep with 1 gang ring
Strobe, 15 candela RSS-24MCW-FW Wheelock 8 4 4 4 0 2 8 4 4 4 0 4 2 7125-0785:141 4" sq x 1-1/2" deep with 1 gang ring
Strobe, Weatherproof WM3T-24-VFR Wheelock 4 0 0 0 0 3 4 0 0 0 0 1 1 7300-0785:011 WBB backbox
Door Holder Power Supply PS5-BFS-24-UL Alarm Saf 1 0 0 0 0 0 1 0 0 0 0 2 7315-1214:100 custom
Magnetic Door Holder FMM-998-24 Notifier 7 7 7 7 0 0 7 7 7 7 0 5 6 3550-0028:177 2" x 4" x 1-3/4" deep box
Constant Power Supply FCPS-24 Notifier 1 1 0 0 0 0 1 1 0 0 0 4 7315-0028:178 custom
-- Battery, 7 AH PS1270 PowerSonic 2 2 0 0 0 0 2 2 0 0 0 8 -- --
Junction Box -- -- 6 4 4 4 1 0 6 4 4 4 1 3 8 -- --
Stand Alone 120v Smoke Detector
(F.B.O., for reference only)
DD
Symbol & CSFM List
FACP
SD
F
DSM
FSD
ANN
Studio 5 - by Floor Studio 6 - by Floor
C
o
m
m
o
n
s
DEVICEQUANTITIES
MM
CR
WF
VT
H
110
PIV
HD
AB
SD
S
SD
CM
APS
H
WP
15
15
WP
DH
FCPS
R
DHPS
J
EOLR
A
la
rm
R= ALARMRECEIPT CAPABILITYDURINGABNORMAL CONDITIONSISREQUIRED.
X
X
R X
X
X
X
X
R X
X
X
X
XR
X X
R X
X
X
X
X
X
X
X
X
X
X
X
T
ro
u
b
le
A
n
n
u
n
c
ia
to
rs
S
u
p
e
rv
is
o
ry
X
F
A
C
P
A
la
rm
X
F
A
C
P
F
A
C
P
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
A
n
n
u
n
c
ia
to
rs
T
ro
u
b
le
A
n
n
u
n
c
ia
to
rs
S
u
p
e
rv
is
o
ry
A
c
tiv
a
te
H
o
rn
s
&
S
tro
b
e
s
X
X X X
X X
Fire Alarm System Operational Matrix
Loss Of Carrier
Open Wire
Shorted Supervisory Wires
Grounded Wire
Open Wire
Heat Detector @ Mach/Elev. Shaft
Elev. Lobby/Shaft/Mach Smoke
Valve Tamper
INITIATINGALARMCIRCUIT STYLE B (CLASS B)
Grounded Wire
Post Indicator Valve
Water Flow
Duct Smoke Detector
Open Wire
Open Wire
Wire To Wire Short & Ground
Wire To Wire Short & Open
Open & Ground
SIGNALINGLINE CIRCUIT STYLE 4 (CLASS B)
Grounded Wire
Shorted Wires
Grounded Wire
NOTIFICATION CIRCUIT STYLE Y (CLASS B)
Shorted Wires
Area Smoke Detector
Area Heat Detector
Handicap Room Smoke Detector
INITIATINGSUP. CIRCUIT STYLE B (CLASS B)
X X X Manual Pull Station
X
X
E
le
v
a
to
rs
R
e
c
a
ll
P
o
w
e
r
S
h
u
n
t
C
lo
s
e
A
s
s
o
c
ia
te
d
F
ire
/S
m
o
k
e
D
m
a
p
e
r
S
h
u
td
o
w
n
A
s
s
o
c
ia
te
d
F
a
n
s
X
X
X
X
X X
X
X
X
X
X
S
ta
n
fo
rd
U
n
iv
e
rs
ity
P
ro
p
rie
ta
ry
S
ta
tio
n
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X X
X
A
c
tiv
a
te
H
C
R
o
o
m
S
o
u
n
d
e
r &
S
tro
b
e
s
X
X
X
X
X
X
X
THE ELECTRICAL CONTRACTOR MUST PROVIDE THE FIRE ALARM CONTRACTOR WITH
ACCURATE MARKED UP DRAWINGS SHOWING ALL JUNCTION BOXES, TERMINAL
CABINETS, DEVICE LOCATIONS, ETC. FOR THE USE IN MAKING "RECORD DRAWINGS".
THE FIRE ALARM COMPANY WILL REVISE DRAWINGS ACCORDINGLY.
CONDUIT ROUTING AND CONDUIT SIZE SHALL BE DETERMINED BY THE
CONTRACTOR, IN CONJUNCTION WITH (NEC), AND INDICATED ON THE RECORD
DRAWINGS. CONDUIT FILL SHALL NOT EXCEED 40%.
FIRE ALARM WIRING SHALL BE INSTALLED PER (NEC) AND THE LOCAL AUTHORITY
HAVING JURISDICTION.
SMOKE DETECTORS SHALL BE MOUNTED IN ACCORDANCE WITH NFPA 72. DETECTORS
SHALL NOT BE LOCATED IN A DIRECT AIR-FLOW NOR CLOSER THAN 3 FEET OF ANY
AIR SUPPLY DIFFUSER.
ALL WORK SHALL BE DONE IN ACCORDANCE WITH CURRENT EDITION OF U.B.C.,
TITLE 19, TITLE 24, NFPA, AND AMERICANS WITH DISABILITIES ACT (ADA) AS
REQUIRED BY THE GOVERNING AGENCIES.
PRIMARY POWER SOURCE (120VAC) TO FACP AND POWER SUPPLIES MUST BE ON A
DEDICATED BRANCH CIRCUIT, FROM THE EMERGENCY GENERATOR (IF APPLICABLE),
WITH THE DISCONNECTING MEANS MARKED "FIRE ALARM CONTROL CIRCUIT". THE
LOCATION OF THE DISCONNECT MUST BE IDENTIFIED AT THE FACP AND POWER
SUPPLIES. ALL FIRE ALARM CIRCUIT BREAKERS MUST BE CLEARLY MARKED AND
MECHANICALLY SECURED TO PREVENT ANY UNAUTHORIZED TAMPERING.
WHEN POWERING UP THE FACP OR REMOTE POWER SUPPLIES BE SURE TO APPLY AC
VOLTAGE BEFORE DC VOLTAGE. WHEN POWERING DOWN REMOVE DC SUPPLY BEFORE
AC DISCONNECT.
DEVICE POLARITY MUST BE OBSERVED.
ALL INITIATING AND NOTIFICATION CIRCUIT WIRING MUST BE SUPERVISED.
ALL WIRING, INCLUDING SHIELDS, MUST BE DRY AND FREE OF SHORTS AND
GROUNDS.
STROBE DEVICES SHALL BE SYNCHRONIZED.
AUDIBLE DEVICES SHALL USE SYNCHRONIZED TEMPORAL (CODE 3) TONE.
ALL DEVICES SHALL BE LABELED WITH THEIR ADDRESS OR CIRCUIT NUMBER.
PROVIDE WEATHER PROOF NEMA ENCLOSURES TO ALL DEVICES THAT ARE EXPOSED
TO THE ENVIRONMENT.
DIFFERENTIAL PRESSURE TESTING FOR DUCT DETECTORS MUST BE PERFORMED BY
THE MECHANICAL CONTRACTOR AFTER AIR HANDLER SYSTEMS HAVE BEEN
BALANCED. A WRITTEN COPY OF THESE TESTS SHALL BE TURNED OVER TO THE
ENGINEER PRIOR TO SYSTEM FINAL.
ALL DUCT DETECTORS TO BE INSTALLED PER MANUFACTURER INSTALLATION
INSTRUCTION AND ALL APPLICABLE NFPA, UBC AND UMC STANDARDS.
ELECTRICAL CONTRACTOR TO PROVIDE ALL CONDUIT, WIRE, BACK BOX, TERMINAL
CABINETS, AS REQUIRED TO COMPLETE THE PROJECT.
ALL JUNCTION BOXES MUST HAVE RED COVERS, TERMINAL CABINETS MUST BE
MARKED "FATC".
ALL FIRE ALARM DEVICES MUST BE INSTALLED IN A PROPER BACK BOX. NO DEVICE
SHALL BE INSTALLED WITHOUT A BACK BOX.
PROVIDE GROUND ROD, OR COLD WATER COPPER PIPE OK IF WATER METER STRAPPED,
FOR PROPER GROUNDING OF THE FIRE ALARM PANEL AND REMOTE POWER SUPPLIES.
INITIATING DEVICE CIRCUITS (IDC) AND NOTIFICATION APPLIANCE CIRCUITS
(NAC), ARE TWO WIRE CLASS "B". NO T-TAPPING IS ALLOWED ON ANY OF THESE
CIRCUITS.
SIGNALING LINE CIRCUITS (SLC) ARE TWO WIRE DATA COMMUNICATIONS
CIRCUITS. T-TAPPING IS NOT ALLOWED.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
Notes:
Project Information
Detail Sheet
Elevation Details
Studio 5 System Calculations
Studio 5 System Calculations
Studio 5 System Calculations
Studio 5 System Calculations
Studio 6 System Calculations
Studio 6 System Calculations
Studio 6 System Calculations
Studio 6 System Calculations
Studio 5 Riser Diagram
Studio 5 Ground Floor Plan
Studio 5 Second Floor Plan
Studio 5 Third Floor Plan
Studio 5 Fourth Floor Plan
Studio 5 Attic Floor Plan
FA0.0-5
FA1.1-5
FA1.2-0
FA1.2-2
FA1.2-3
FA1.2-4
FA1.2-5
FA1.2-6
FA1.2-7
FA1.2-8
FA1.2-9
FA2.0-5
FA2.1-5
FA2.2-5
FA2.3-5
FA2.4-5
FA2.5-5
Drawing Schedule:
Commons Building Floor Plan
Studio 6 Riser Diagram
Studio 6 Ground Floor Plan
Studio 6 Second Floor Plan
Studio 6 Third Floor Plan
Studio 6 Fourth Floor Plan
Studio 6 Attic Floor Plan
Product Data Sheets
Product Data Sheets
Product Data Sheets
Product Data Sheets
Product Data Sheets
CSFM Listing Sheets
CSFM Listing Sheets
FA2.6-C
FA2.0-6
FA2.1-6
FA2.2-6
FA2.3-6
FA2.4-6
FA2.5-6
FA6.0
FA6.1
FA6.2
FA6.3
FA6.4
FA7.0
FA7.1
Building Information:
GENERAL DESCRIPTION:
SPRINKLERS:
OCCUPANCY TYPE:
OCCUPANCY SEPARATIONS:
CONSTRUCTION TYPE:
R-1
1-hour
Type V, 1hr Residential
Two 4 stories buildings housing 163 graduate student
apartments each plus one Commons building, 1 story in
height housing student services and support facilities.
Fully sprinkled, NFPA 13, 1996 Version, Light Hazard
RESIDENTIAL COMMONS
B
1-hour
Type V NR
Project Directory:
OWNER'S REPRESENTATIVE
Susan Rozakis
Stanford University
Capital Planning and Management
655 Serra Street
Stanford, CA 94305-6114
Tel: (650) 723-1813
Fax: (650) 723-7444
DESIGN ARCHITECTS
Solomon E.T.C.
246 First St. Suite 400
San Francisco, CA 94105
Tel: (415) 227-4081
Fax: (415) 777-5306
ARCHITECT OF RECORD
James Guthrie and Associates, Architects
1 Water Park Drive Suite 108
San Mateo, CA 94403
Tel: (650) 572-1911
Fax: (650) 572-0977
STRUCTURAL ENGINEER
Dominic Chu
3724 S. El Camino Real
San Mateo, CA 94403
Tel: (650) 578-9899
Fax: (650) 578-0240
CONCRETE ENGINEER
CEC Engineering International
100 Park Place Suite 1555
San Ramon, CA 94583
Tel: (925) 831-6155
Fax: (925) 831-6189
PLUMBING & H.V.A.C.
Design Engineering Services
82 Second St.
San Francisco, CA 94105
Tel: (415) 546-7905
Fax: (415) 495-6352
ELECTRICAL ENGINEER
1st Engineering
155 East Campbell, Suite 107
Campbell, CA 95008
Tel: (408) 370-3170
Fax: (408) 370-3172
CIVIL ENGINEER
Brian Kangas Foulk
4780 Chabot Drive Suite 104
Pleasanton, CA 94588-3323
Tel: (925) 396-7700
Fax: (925) 396-7799
LANDSCAPE ARCHITECT
SWA Group
2200 Bridgeway Boulevard
Sausalito, CA 94966-5906
Tel: (415) 332-5100
Fax: (415) 332-0719
ELEVATOR CONSULTANT
Hesselberg Keesee
221 Main St. Suite 1580
San Francisco, CA 94105
Tel: (415) 243-0313
Fax: (415) 243-0781
INITIATING DEVICE CIRCUITS (IDC) = CLASS "B", STYLE "B"
SIGNALLING LINE CIRCUITS (SLC) = CLASS "B", STYLE "4"
NOTIFICATION APPLIANCE CIRCUITS (NAC) = CLASS "B" STYLE "Y"
Style/Circuit Designations (per NFPA 72, 1996 edition):