Input Data For System

The document provides input data for the air system serving the second floor of a library project. Key details include: - The air system serves a single zone and includes a split air handling unit with a forward curved supply fan and air-cooled DX cooling. - It will provide approximately 13,000 CFM of supply air including 1,725 CFM of outdoor air to the second floor zone. - The second floor zone includes three spaces (computer section, general reading, and office room) and will be cooled to 75°F when occupied and 85°F when unoccupied.

Uploaded by

M Hamza Nadeem
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as RTF, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
28 views

Input Data For System

The document provides input data for the air system serving the second floor of a library project. Key details include: - The air system serves a single zone and includes a split air handling unit with a forward curved supply fan and air-cooled DX cooling. - It will provide approximately 13,000 CFM of supply air including 1,725 CFM of outdoor air to the second floor zone. - The second floor zone includes three spaces (computer section, general reading, and office room) and will be cooled to 75°F when occupied and 85°F when unoccupied.

Uploaded by

M Hamza Nadeem
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as RTF, PDF, TXT or read online on Scribd
You are on page 1/ 2

Floor 2 Input Data

Project Name: Floor 2 Library


Prepared by: uet

05/16/2014
06:08PM

1. General Details:
Air System Name .................................................................................... Floor 2
Equipment Type ................................................................................. Split AHU
Air System Type ..................................................................... Single Zone CAV
Number of zones ............................................................................................... 1
2. System Components:
Ventilation Air Data:
Airflow Control .................................................... Constant Ventilation Airflow
Ventilation Sizing Method ...................................... Sum of Space OA Airflows
Unocc. Damper Position ......................................................................... Closed
Damper Leak Rate ............................................................................................ 0 %
Outdoor Air CO2 Level .................................................................................. 400 ppm
Central Cooling Data:
Supply Air Temperature ............................................................................... 58.0 F
Coil Bypass Factor ..................................................................................... 0.150
Cooling Source ........................................................................... Air-Cooled DX
Schedule ................................................................................ * * * AMJJAS* * *
Capacity Control .............................. Cycled or Staged Compressor - Fan On
Supply Fan Data:
Fan Type ................................................................................. Forward Curved
Configuration ..................................................................................... Draw-thru
Fan Performance ......................................................................................... 0.00 in wg
Overall Efficiency ............................................................................................ 54 %
Duct System Data:
Supply Duct Data:
Duct Heat Gain ................................................................................................. 0 %
Duct Leakage .................................................................................................... 0 %
Return Duct or Plenum Data:
Return Air Via ............................................................................. Ducted Return
3. Zone Components:
Space Assignments:
Zone 1: Zone 1
Z1:F2:Computer Section
Z2:F2:General Reading
Z3:F2:Office Room

x1
x1
x1

Thermostats and Zone Data:


Zone ............................................................................................................... All
Cooling T-stat: Occ. ..................................................................................... 75.0
Cooling T-stat: Unocc. ................................................................................. 85.0
Heating T-stat: Occ. ..................................................................................... 70.0
Heating T-stat: Unocc. ................................................................................. 60.0
T-stat Throttling Range ................................................................................ 1.50
Diversity Factor ............................................................................................. 100
Direct Exhaust Airflow .................................................................................... 0.0
Direct Exhaust Fan kW .................................................................................. 0.0

F
F
F
F
F
%
CFM
kW

Thermostat Schedule ......................................................... Floor 2 Thermostat


Unoccupied Cooling is ........................................................................ Available
Supply Terminals Data:
Zone ............................................................................................................... All
Terminal Type ........................................................................................ Diffuser
Minimum Airflow ........................................................................................... 0.00 CFM/person

Zone Heating Units:


Zone ............................................................................................................... All
Hourly Analysis Program v.4.4

Page 1 of 2

Floor 2 Input Data


Project Name: Floor 2 Library
Prepared by: uet

05/16/2014
06:08PM

Zone Heating Unit Type ............................................................................. None


Zone Unit Heat Source ...................................................... Electric Resistance
Zone Heating Unit Schedule ................................................. JFMAMJJASOND
4. Sizing Data (Computer-Generated):
System Sizing Data:
Cooling Supply Temperature ....................................................................... 58.0 F
Supply Fan Airflow ................................................................................. 13035.8 CFM
Ventilation Airflow ..................................................................................... 1725.0 CFM
Hydronic Sizing Specifications:
Chilled Water Delta-T ................................................................................... 10.0 F
Hot Water Delta-T ........................................................................................ 20.0 F
Safety Factors:
Cooling Sensible ............................................................................................... 0 %
Cooling Latent ................................................................................................... 0 %
Heating .............................................................................................................. 0 %
Zone Sizing Data:
Zone Airflow Sizing Method .................................. Sum of space airflow rates
Space Airflow Sizing Method .............................. Individual peak space loads

Zone

Supply Airflow
(CFM)

13035.8

Zone Htg Unit


(MBH)

Reheat Coil
(MBH)

5. Equipment Data
Central Cooling Unit - Air-Cooled DX
Estimated Maximum Load ......................................................................... 520.9
Design OAT .................................................................................................. 95.0
Equipment Sizing ............................................................................. Auto-Sized
Capacity Oversizing Factor ............................................................................ 0.0
ARI Performance Rating ............................................................................ 10.10
Conventional Cutoff OAT ............................................................................. 55.0
Low Temperature Operation ................................................................ Not used

Hourly Analysis Program v.4.4

(CFM)

MBH
F
%
EER
F

Page 2 of 2