Input Data For System
Input Data For System
05/16/2014
06:08PM
1. General Details:
Air System Name .................................................................................... Floor 2
Equipment Type ................................................................................. Split AHU
Air System Type ..................................................................... Single Zone CAV
Number of zones ............................................................................................... 1
2. System Components:
Ventilation Air Data:
Airflow Control .................................................... Constant Ventilation Airflow
Ventilation Sizing Method ...................................... Sum of Space OA Airflows
Unocc. Damper Position ......................................................................... Closed
Damper Leak Rate ............................................................................................ 0 %
Outdoor Air CO2 Level .................................................................................. 400 ppm
Central Cooling Data:
Supply Air Temperature ............................................................................... 58.0 F
Coil Bypass Factor ..................................................................................... 0.150
Cooling Source ........................................................................... Air-Cooled DX
Schedule ................................................................................ * * * AMJJAS* * *
Capacity Control .............................. Cycled or Staged Compressor - Fan On
Supply Fan Data:
Fan Type ................................................................................. Forward Curved
Configuration ..................................................................................... Draw-thru
Fan Performance ......................................................................................... 0.00 in wg
Overall Efficiency ............................................................................................ 54 %
Duct System Data:
Supply Duct Data:
Duct Heat Gain ................................................................................................. 0 %
Duct Leakage .................................................................................................... 0 %
Return Duct or Plenum Data:
Return Air Via ............................................................................. Ducted Return
3. Zone Components:
Space Assignments:
Zone 1: Zone 1
Z1:F2:Computer Section
Z2:F2:General Reading
Z3:F2:Office Room
x1
x1
x1
F
F
F
F
F
%
CFM
kW
Page 1 of 2
05/16/2014
06:08PM
Zone
Supply Airflow
(CFM)
13035.8
Reheat Coil
(MBH)
5. Equipment Data
Central Cooling Unit - Air-Cooled DX
Estimated Maximum Load ......................................................................... 520.9
Design OAT .................................................................................................. 95.0
Equipment Sizing ............................................................................. Auto-Sized
Capacity Oversizing Factor ............................................................................ 0.0
ARI Performance Rating ............................................................................ 10.10
Conventional Cutoff OAT ............................................................................. 55.0
Low Temperature Operation ................................................................ Not used
(CFM)
MBH
F
%
EER
F
Page 2 of 2