0% found this document useful (0 votes)
468 views

API Standard Storage Tank Data Sheet

This document is an API Standard 650 data sheet that provides specifications for a storage tank. It includes sections detailing the tank's nominal capacity, materials, dimensions, design standards, environmental considerations, and planned appurtenances. The data sheet is addressed to the purchaser/agent and specifies requirements to meet API Standard 650 for the safe design, fabrication, and erection of storage tanks.

Uploaded by

juanchocazon78
Copyright
© © All Rights Reserved
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
468 views

API Standard Storage Tank Data Sheet

This document is an API Standard 650 data sheet that provides specifications for a storage tank. It includes sections detailing the tank's nominal capacity, materials, dimensions, design standards, environmental considerations, and planned appurtenances. The data sheet is addressed to the purchaser/agent and specifies requirements to meet API Standard 650 for the safe design, fabrication, and erection of storage tanks.

Uploaded by

juanchocazon78
Copyright
© © All Rights Reserved
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 3

API STANDARD 650

STORAGE TANK
DATA SHEET
1 3
m
3
(bbl) m
3
(bbl)
m
3
/h (bbl/h) m
3
/h(bbl/h)
0
C (
0
F)
0
C (
0
F)
0
C (
0
F) kPa (in. water)
mm(in.) mm (in.)
mm(in.) mm (in.)
kPa (lbf/in.
2
)
kPa (lbf/in.
2
)
kPa (lbf/in.
2
)
kPa (lbf/in.
2
)
0
C (
0
F)
km/h (mph)
mm/h (in./h)
mm (in.)
m (ft) m (ft)
APPURTENANCES (TO BE COMPLETED BY MANUFACTURER AND/OR PURCHASER
June 18, 2014
DATE
BY
FILE NO.
PAGE O
1. PURCHASER/AGENT

CITY
PROV/STATE
PC/ZI PHONE
2. USER
3. ERECTION NAME OF PLANT
LOCATION
4. TANK
NOMINAL CAPACITY
NET WORKING CAPACITY
PUMPING RATES: I
OUT
6. MAXIMUM OPERATING TEMPERATURE
7. PRODUCT STORED:
DESIGN SPECIFIC GRAVITY A
DESIGN METAL TEMPERATURE
VAPOR PRESSURE
8. CORROSION ALLOWANCE: SHEL
ROOF
BOTTOM
STRUCTURALS
9. SHELL DESIGN:
BASIC STANDARD 650
APPENDIX A APPENDIX F
DESIGN PRESSURE
10. ROOF DESIGN:
BASIC STANDARD 650 APPENDIX C (EXTERNAL FLOATING)
APPENDIX G (ALUMINUM DOME) APPENDIX H (INTERNAL FLOATING)
FRANGIBLE ROOF JOINT?
YES NO NOTE FOR SHOP TANKS
11. ROOF DESIGN INFORMATION:
UNIFORM LIVE LOAD
SPECIAL LOADS (PROVIDE) SKETCH)
INSULATION
MAXIMUM DESIGN ROOF TEMPERATURE A
GASES IN THE VAPOR SPACE
12. EARTHQUAKE DESIGN?
YES NO (APPENDIX B)
ROOF TIE RODS (3,10,4,5)?
YES NO
SEISMIC ZONE IMPORTANCE FACTOR
ZONE FACTOR (TABLE E-2) SITE COEFFICIENT (TABLE E-3)
13. WIND LOAD: VELOCITY
PROVIDE INTERMEDIATE WIND GIRDER (3.9.7)?
YES NO
14. ENVIRONMENTAL EFFECTS: MAXIMUM RAINFALL
TOTAL SNOW ACCUMULATION
15. SIZE RESTRICTIONS
MAXIMUM DIAMETER
MAXIMUM HEIGHT
16. FOUNDATION TYPE:
EARTH CONCRETE RINGWALL OTHER
REMARKS
API STANDARD 650
STORAGE TANK
DATA SHEET
June 18, 2014
DATE
BY
FILE NO.
2 3

1.
2.
3.
mm(in.)
mm/m (in/ft)
CONSTRUCTION DETAILS (TO BE COMPLETED BY MANUFACTURER AND/OR PURCHASER

1. MANUFACTURER

CITY PROV/STATE PC/ZI PHONE
SERIAL NO.
2. FABRICATOR

CITY PROV/STATE PC/ZI PHONE
SERIAL
3. MATERIAL SPECIFICATIONS SHELL


STRUCTURALS
4. NO. OF SHELL COURSES
5. PLATE WIDTHS AND THICKNESSES (INCLUDING CORROSION ALLOWANCE), IN mm (in.)
4 7
5 8
6 9
6. TANK BOTTOM:
PLATE THICKNESS
LAP BUTT
SEAMS
SLOP
TO FROM
CENTE
7. MINIMUM WIDTH AND THICKNESS OF BOTTOM ANNULAR PLATES (3.5) IN mm (in.):
8. ROOF-TO-SHELL DETAIL (FIGURE F-1)
9. INTERMEDIATE WIND GIRDER?
YES NO
TOP WIND GIRDER FOR USE AS WALKWAY?
YES NO
10. ROOF TYPE:
SUPPORTED SELF-SUPPORTED FLOATING
SLOPE OR
mm
11. ROOF PLATE: THICKNES mm
LAP
BUTT JOINT
12.
SHELL-- EXTERIOR?
YES NO
INTERIOR?
YES
NO
SURFACE PREPARATION
BOTTOM-- UNDERSIDE?
YES NO
INTERIOR?
YES NO
SURFACE PREPARATION
STRUCTURAL STEEL-- EXTERIOR?
YES NO
INTERIOR?
YES NO
SPECIFICATION
13. TANK BOTTOM COATING: INTERIOR?
YES NO
MATERIAL
APPLICATION SPECIFICATION
14. INSPECTION SHOP FIEL
15. WELD EXAMINATION: RADIOGRAPH
SUPPLIEMENTARY LIQUID PENETRANT OR ULTRASONIC
16. PROPERTY OF
17. LEAK TESTING: BOTTOM ROO
SHEL
18. MILL TEST REPORTS: REQUIRED?
YES NO
PLAT STRUCTURAL SHAPES
19. PURCHASER'S REFERENCE DRAWING
20. TANK SIZE: DIAMETER m
HEIGH
m
21. DATE OF STANDARD 650
REMARKS
PAGE
O
API STANDARD 650
STORAGE TANK
DATA SHEET
June 18, 2014
DATE
BY
FILE NO.
3 3
m
2
(ft
2
)
ORIENTATION HEIGHT FROM
MARK SIZE SGL DBL SPL A B C D E N=0 BOTTOM SERVICE
11. ROOF NOZZLES, INCLUDING VENTING CONNECTION (SEE FIGURES 3-14 AND 3-15 AND TABLES 3-16 AND 3-17
ORIENTATION DISTANCE FROM
MARK SIZE N=0 CENTER SERVICE
NOTE: SKETCHES AND/OR SEPARATE SHEETS MAY BE ATTACHED TO COVER SPECIAL REQUIREMENTS.
FLANGED THREADED REINFORCEMENT
FLANGED THREADED
APPURTENANCES (TO BE COMPLETED BY MANUFACTURER AND/OR PURCHASER
1. STAIRWAY STYLE:
CIRCULAR STRAIGHT
ANGLE TO HORIZONTAL DEGREES
LADDER
2. WALKWAY: WIDT mm LENGTH m
3. DRAWOFF SUMP: STANDARD SPECIA
4. BOLTED DOOR SHEET?
YES NO (APPENDIS a TANKS ONLY) RAISED FLUSH
5. SCAFFOLD HITCH
6. INTERNAL SWING SUCTION
HEATING COIL SURFACE AREA
7. ROOF HOS JOINTED
SIPHO
8. NO. AND SIZE OF SHELL MANHOLES
9. NO. AND SIZE OF ROOF MANHOLES
10. SHELL NOZZLES (SEE FIGURES 3-4B, 3-5, AND 3-7 AND TABLES 3-8, 3-9, AND 3-10):
PAGE O