0% found this document useful (0 votes)
50 views1 page

3-Pole Contactors: AC / DC Control Voltage

This document provides information on 3-pole contactors from ABB, including their rated power, operational current, motor ratings, protection options, switching capabilities for resistive circuits, main accessories, and interlock options. It lists numerous contactor models ranging from 9A to 38A and their corresponding specifications.

Uploaded by

Diana Kennedy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
50 views1 page

3-Pole Contactors: AC / DC Control Voltage

This document provides information on 3-pole contactors from ABB, including their rated power, operational current, motor ratings, protection options, switching capabilities for resistive circuits, main accessories, and interlock options. It lists numerous contactor models ranging from 9A to 38A and their corresponding specifications.

Uploaded by

Diana Kennedy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

3-pole Contactors

AC / DC control voltage

AF09

AF12

AF16

AF26

AF09-30-10 AF12-30-10 AF16-30-10

AF30

AF38

AF26-30-00 AF30-30-00 AF38-30-00

AF09-30-01 AF12-30-01 AF16-30-01

Switching of 3-phase Cage Motors


Rated power
33

IEC

UL/CSA

AC-3

Rated
operational
current

400 V
60 C

400 V

60 C

415 V

60 C

690 V
480 V

Motor rating

NEMA size

4 kW
9A
9A
7A
5 hp
00

5.5 kW
12 A
12 A
9A
7.5 hp
0

7.5 kW
18 A
18 A
10.5 A
10 hp
-

11 kW
26 A
26 A
17 A
15 hp
1

15 kW
32 A
32 A
21 A
20 hp
-

18.5 kW
38 A
38 A
24 A
20 hp
-

Protection of 3-phase motors


TF42...
Thermal overload relays

setting range in A

0.10 ... 0.13 0.23 ... 0.31 0.55 ... 0.74 1.30 ... 1.70 3.10 ... 4.20 7.60 ... 10.0 16.0 ... 20.0 29.0 ... 35.0
0.13 ... 0.17 0.31 ... 0.41 0.74 ... 1.00 1.70 ... 2.30 4.20 ... 5.70 10.0 ... 13.0 20.0 ... 24.0 35.0 ... 38.0
0.17 ... 0.23 0.41 ... 0.55 1.00 ... 1.30 2.30 ... 3.10 5.70 ... 7.60 13.0 ... 16.0 24.0 ... 29.0

EF19...

Electronic overload relays

0.10 ... 0.32

EF45...

setting range in A

setting range in A

0.30 ... 1.00 0.80 ... 2.70 1.90 ... 6.30 5.70 ... 18.9
9.00 ... 30.0

15.0 ... 45.0

Switching of Resistive Circuits


33

IEC

AC-1

Rated
operational
current

40 C

690 V

60 C

690 V

70 C

690 V

With conductor cross-sectional area


R
R

UL/CSA

General use rating


With conductor cross-sectional area

600 V AC

25 A
25 A
22 A
4 mm2
25 A
AWG 10

28 A
28 A
24 A
6 mm2
28 A
AWG 10

30 A
30 A
26 A
6 mm2
30 A
AWG 10

45 A
40 A
32 A
10 mm2
45 A
AWG 8

50 A
42 A
37 A
10 mm2
50 A
AWG 8

50 A
42 A
37 A
10 mm2
50 A
AWG 8

Main Accessories
1-pole CA4-10 or CA4-01, CC4-10 or CC4-01
Auxiliary
contact
blocks

4-pole CA4

Front mounting

2-pole CAT4-11 (with coil front connection)


2-pole CAL4-11

Side mounting

Mechanical / electrical

VEM4
including VM4 mechanical interlock unit and VE4 electrical interlock block with A2-A2 connection

Interlocks
VM4

Mechanical

including 2 fixing clips

Reversing Starters

BER16-4

BER38-4

Star-Delta Starters

BEY16-4

BEY38-4

1SBC 101 090 S0201

Connection
sets

ABB | 3