0% found this document useful (0 votes)
43 views1 page

Spreadsheet For Sign Structure - Reinforcement

This document analyzes the steel reinforcement for a beam with a width of 12 inches, effective depth of 4 inches, and concrete compressive strength of 2,500 psi. It finds that the area of tension reinforcing is 0 square inches, resulting in an actual reinforcement ratio of 0 and nominal moment capacity of 0 foot-pounds. It therefore recommends using two mats of reinforcing bars on top and bottom with a specified size and spacing.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
43 views1 page

Spreadsheet For Sign Structure - Reinforcement

This document analyzes the steel reinforcement for a beam with a width of 12 inches, effective depth of 4 inches, and concrete compressive strength of 2,500 psi. It finds that the area of tension reinforcing is 0 square inches, resulting in an actual reinforcement ratio of 0 and nominal moment capacity of 0 foot-pounds. It therefore recommends using two mats of reinforcing bars on top and bottom with a specified size and spacing.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

6/9/2014

11:15 AM

STEEL REINFORCEMENT ANALYSIS


Project: FOR EDUCATION ONLY; NOT TO BE USED FOR COMMERCIAL WORK.
Descript: DESCRIPTION
Ref: Uniform Building Code 1994, ACI 318-89
Width of strip to analyze, b=
Effective depth of beam, d=
Compressive strength of concrete, f'c=

12.00
-4.00
2,500

in
in, providing 3"+ cover
psi
B1=

Area of tension reinforcing, As=


Yield strength of reinforcing, fy=

0.00
60,000

sq in, per 12" strip


psi, using Grade 60 deformed bar

Maximum reinforcement ration=


Actual reinf ratio, p= 2(As/(b x d))=
Minimum reinforcement ratio=

0.0134
0.0000
0.0014

as 75% of balanced ratio


counting top and bottom bars
temperature and shrinkage

Depth of Whitney rectangular stress block, a= (As x fy)/(0.85 x f'c x b)=


Depth of neutral axis, x= a/B1=

0.85

0.00
0.00

in
in

Nominal moment capacity of a 12" strip, Mn= (As x fy)(d-(a/2))= 0.00E+00 lb-ft
Design moment capacity of a 12" strip, [phi]Mn= 0.9 x Mn= 0.00E+00 lb-ft
Actual factored moment on a 12" strip of the footing= #DIV/0! lb-ft
#DIV/0!

Use two mats of reinforcing, top and bottom (3" cover) of:
#X bars at XX" OC perpendicular to sign face
# X bars at XX" OC parallel to sign face

Average Steel Area (per foot of width)

Bar
#3
#4
#5
#6
#7
#8
#9
#10
#11

4"oc
0.33
0.59
0.92
1.32
1.80
2.36
3.00
3.80
4.69

5"oc
0.26
0.47
0.74
1.06
1.44
1.88
2.40
3.04
3.75

Spacing of bars in inches


6"oc
7"oc
8"oc
0.22
0.19
0.17
0.39
0.34
0.29
0.61
0.53
0.46
0.88
0.76
0.66
1.20
1.03
0.90
1.57
1.35
1.18
2.00
1.71
1.50
2.53
2.17
1.89
3.12
2.68
2.34

9"oc
0.15
0.26
0.41
0.59
0.80
1.05
1.33
1.69
2.08

10"oc
0.13
0.24
0.37
0.53
0.72
0.94
1.20
1.52
1.87

12"oc
0.11
0.20
0.31
0.44
0.60
0.78
1.00
1.27
1.56

You might also like