0% found this document useful (0 votes)
164 views3 pages

Hust H4X: HMI Setting

This document provides instructions for connecting a HUST H4X PLC to various HMI models for data exchange. It includes settings for the PLC interface, device addressing formats and ranges, and wiring diagrams for connecting the PLC serial port to each HMI's COM port. Proper connection allows reading and writing of PLC registers mapped to addresses in the HMI's virtual memory.

Uploaded by

JavadSoltani
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
164 views3 pages

Hust H4X: HMI Setting

This document provides instructions for connecting a HUST H4X PLC to various HMI models for data exchange. It includes settings for the PLC interface, device addressing formats and ranges, and wiring diagrams for connecting the PLC serial port to each HMI's COM port. Proper connection allows reading and writing of PLC registers mapped to addresses in the HMI's virtual memory.

Uploaded by

JavadSoltani
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

PLC Connection Guide

HUST H4X
Supported Series: HUST CNC Controller H4 Series.
Website: http://www.hust.com.tw/
HMI Setting:
Parameters Recommended Options Notes
PLC type HUST H4X
PLC I/F RS-232 CPU port
Baud rate 38400 9600,19200,38400,57600
Data bits 7
Parity Even
Stop bits 2
Turn around delay 5
PLC sta. no. 1

Device Address:
Bit/Word Device type Format Range Memo
B I DDD 0 ~ 255
Mapping to VM 10800 ~ 10807 (read
only)
B O DDD 0 ~ 255
Mapping to VM 10808 ~ 10815 (read
only)
B C DDD 0 ~ 255
Mapping to VM 10816 ~ 10823 (read
only)
B S DDD 0 ~ 255
Mapping to VM 10824 ~ 10831 (read
only)
B A DDD 0 ~ 255
Mapping to VM 10832 ~ 10863 (read
only)
B VM_bit DDDDDdd 100 ~ 9999931 Bit address (dd): 00 ~ 31
DW VM DDDDD 1 ~ 99999
Please refer to the controller
specification for register range.
DW R DDD 0 ~ 255
Mapping to VM 10000 ~ 10255 (read
only)
DW Cn DDD 0 ~ 255
Mapping to VM 10256 ~ 10511 (read
only)
DW Tm DDD 0 ~ 255
Mapping to VM 10512 ~ 10767 (read
only)
PLC Connection Guide
Wiring Diagram:
The following is the view from the soldering point of a cable.
eMT3000 series
COM1 RS232 9P
D-Sub Female
COM3 RS232 9P
D-Sub Female
HUST CNC Controller
RS232 D-Sub Male
2 RX 8 RX 2 TXD
3 TX 7 TX 3 RXD
5 GND 5 GND 5 GND
7 RTS
8 CTS
circuit



cMT/mTV series
COM1 RS232 9P
D-Sub Female
HUST CNC Controller
RS232 D-Sub Male
2 RX 2 TXD
3 TX 3 RXD
5 GND 5 GND
7 RTS
8 CTS
circuit



MT8000iE series
COM1 RS232 9P
D-Sub Female
HUST CNC Controller
RS232 D-Sub Male
2 RX 2 TXD
3 TX 3 RXD
5 GND 5 GND
7 RTS
8 CTS
circuit




PLC Connection Guide
MT6000/8000 series except MT6050i/MT8050i
COM1 RS232 9P
D-Sub Female
COM2 RS232 9P
D-Sub Female
COM3 RS232 9P
D-Sub Male
HUST CNC Controller
RS232 D-Sub Male
2 RX 6 RX 8 RX 2 TXD
3 TX 4 TX 7 TX 3 RXD
5 GND 5 GND 5 GND 5 GND
7 RTS
8 CTS
circuit

MT6050i/MT8050i
COM1 RS232 9P
D-Sub Female
HUST CNC Controller
RS232 D-Sub Male
9 RX 2 TXD
6 TX 3 RXD
5 GND 5 GND
7 RTS
8 CTS
circuit




Driver Version: