Errors occurred during an activation check of BW objects. Several InfoObjects and their associated DDIC objects were found to be inactive and were automatically activated. Additionally, the structure/table for InfoSource 0PROFIT_CTR was inactive and needed to be activated, along with the transfer rules for that InfoSource.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as TXT, PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
121 views
Error Logs
Errors occurred during an activation check of BW objects. Several InfoObjects and their associated DDIC objects were found to be inactive and were automatically activated. Additionally, the structure/table for InfoSource 0PROFIT_CTR was inactive and needed to be activated, along with the transfer rules for that InfoSource.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as TXT, PDF, TXT or read online on Scribd
You are on page 1/ 1
ERROR: Errors occurred during ACTIVATION CHECK.
For more information, see the lo
g file of the background job RSUPGRCHECK.BIH. The following is the content of th e summery error log file: ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ACTIVATION CHECK ERRORS and RETURN CODE in RSUPGRCHECK.BIH ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ 4 ER7000 "Check for DDIC Consistency of BW Objects" " " " " " " 4 ER7000 "InfoObjects Check" " " " " " " 4 ER7000 "Activate all Dictionary objects ( 3028 ):" " " " " " " 4 ER7854 All DDIC objects have been activated / deleted 2EER7000 "InfoObject /CPMB/E9DGWRH is not" "consistent. Activate it." " " " " 3WER7030 InfoObject "/CPMB/E9DGWRH": "TABL" "/B28/PE9DGWRH" is not active - acti vating InfoObject now 3WER7030 InfoObject "/CPMB/E9DGWRH": "TTYP" "/B28/WPE9DGWRH" is not active - act ivating InfoObject now 3WER7030 InfoObject "/CPMB/E9DGWRH": "VIEW" "/B28/ME9DGWRH" is not active - acti vating InfoObject now 3WER7030 InfoObject "/CPMB/E9DGWRH": "TTYP" "/B28/WME9DGWRH" is not active - act ivating InfoObject now 2EER7000 "InfoObject Z_PROD is not" "consistent. Activate it." " " " " 3WER7030 InfoObject "Z_PROD": "TABL" "/BIC/SZ_PROD" is not active - activating I nfoObject now 4 ER7000 "End of Checks for InfoObjects" " " " " " " 4 ER7000 "InfoCubes Check" " " " " " " 4 ER7000 "End of Checks for InfoCubes" " " " " " " 4 ER7000 "Transfer Rules Check" " " " " " " 2EER7000 "Structure/table /BIC/CAAB0PROFIT_CTR_ATTR is not" "active" " " " " 2EER7000 "Activate Transfer Rules for InfoSource 0PROFIT_CTR" "Source System PC_ FILE" " " " "