0% found this document useful (0 votes)
1K views6 pages

Sudha House

This document summarizes a residential house in Delhi designed to be energy efficient. The duplex house uses passive solar design principles like south orientation and shading to minimize energy needs. It features a wind tower, solar chimneys, insulated walls and roof, and integrated solar water heating and cooking. Kitchen and garden waste are composted on site. Electrical loads are minimized through efficient lighting and appliances. The house requires no mechanical heating or cooling and gets emergency power from an inverter and batteries, with plans for future solar panels.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
1K views6 pages

Sudha House

This document summarizes a residential house in Delhi designed to be energy efficient. The duplex house uses passive solar design principles like south orientation and shading to minimize energy needs. It features a wind tower, solar chimneys, insulated walls and roof, and integrated solar water heating and cooking. Kitchen and garden waste are composted on site. Electrical loads are minimized through efficient lighting and appliances. The house requires no mechanical heating or cooling and gets emergency power from an inverter and batteries, with plans for future solar panels.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

Climatic Zone: Composite

1

Residence for Sudha and Atam Kumar, Delhi
Climatic Zone: Composite

Residence for Sudha and Atam Kumar, Delhi
A residenti al house i n a composite cli mate responding to varyi ng
seasonal needs and maintaining comfort levels without any energy-intensive
systems

General description

Thi s i s the i naugural project i n a seri es of EASE (envi ronmentall y
appeal i ng and savi ng energy) houses. EASE i s a concept promoted by Cdr.
C P Sharma (Retd.) as a commerci al l y viabl e method to propagate energy-
effi ci ent houses. Thi s parti cul ar project was sol d to a sol ar energy devi ce
manufacturer and consul tant, who, i nteresti ngl y, was al so the energy
consul tant for of the buil di ng.

The house i s a dupl ex structure wi th a l i vi ng room, ki tchen, three
bedrooms, and a study. There i s an outhouse wi th a servants uni t and
offi ce.
Design features
Envelope design
Site selection
From wi thi n the overal l devel opment, the si te sel ected had a road
to i ts south and west. The l onger si de of the pl ot faced south. The
road on the south was the wi der one, reduci ng possi bili ti es of
shadows from the south i n the future.
Planning of built volumes
The house was pl anned as a dupl ex to further reduce i ts footpri nt
on the pl ot and was shi fted as far north wi thi n the si te, to the
extent feasi bl e, to al l ow for a l arge south open area.
Climatic Zone: Composite

2

Residence for Sudha and Atam Kumar, Delhi
Materials and methods of construction
Reflective finish
The wal l s are cl ad i n whi te sandstone provi di ng a textured and
refl ecti ve fi ni sh.
The roofs are fi ni shed i n whi te terrazzo maki ng for good terraces to
si t out on as wel l as excel l ent refl ecti on characteri sti cs.
Recessed jambs
All wi ndows have an i ndented l i ntel , si ll , and jambs, creati ng space
for hangi ng the curtai ns whi l e at the same ti me ensuri ng that when
the curtai ns are drawn, they fal l i n a way that creates a reasonabl y
dead ai r gap between the curtai n and the gl ass, i mprovi ng the
i nsul ati on characteri sti cs.
Passive solar design
South orientation
The house was ori ented such that every habi tabl e room has a
li beral south exposure. Onl y entri es, toi lets, and stai rcases are
wi thout di rect south ori entati on.
The three bedrooms and the l i vi ng room al l have l arge south gl azi ng
for wi nter heat gai n wi th proper overhang protecti on for preventi on
of summer heat gai n.
The south overhang soffi t l evel i s hi gher than the wi ndow l i ntel
l evel so as to ensure that even a part of the wi ndows i s not shaded
i n wi nter. Al l wi nter heati ng needs can be met by the south
gl azi ng.
Solar chimneys
South-faci ng thi n-wall ed and dark-col oured shafts assi st ai r exhaust
i n the summer days.
The shafts are topped wi th fi bregl ass chi mneys. Internal shutters
cut out thi s exhaust when requi red (i n the wi nter).
Climatic Zone: Composite

3

Residence for Sudha and Atam Kumar, Delhi
Evaporative wind tower
A mul ti -di recti onal wi nd tower fi tted wi th evaporati ve cool i ng pads
tops the stai rwel l .
Outsi de ai r, cool ed by fl owi ng past the pads kept wet by ci rcul ati on
pump, fal l s down thi s wel l and enters the rooms through permanent
venti l ati on openi ngs above the doors. These openi ngs may be
cl osed wi th shutters i f requi red.
Energy-efficient systems
Insulation and mass
Expanded pol ystyrene (25-mm thi ck) i nsul ati on i s provi ded near the
outer surface of the walls so as to retain the mass of the wall acting in
tandem with the internal space.
Likewise, asbestos powder (40-80-mm thi ck) i nsul ati on i s provi ded over
the roof sl ab. Both these provi de for a hi ghly inert house with high
thermal mass and hi gh insul ati on.
Daylight
All spaces i n the house are properl y l i t by natural l i ght i n the day.
Low energy lights
All l amps and l umi nari es are based on warm col our CFLs (compact
fl uorescent l amps) so as to reduce el ectri cal l oads to the maxi mum.
Overall rationalization of loads
Incl udi ng fans, l i ghts, refri gerator, and a water ci rcul ati on pump for
the cool i ng tower, the runni ng l oads of the house work out to about
400 W. Addi ng a TV/computer or water boosti ng pump (not runni ng
si mul taneousl y), the running load of the house i s about 800 W. If
one heavy appl i ance (el ectri c i ron, washi ng machi ne, etc., not
runni ng si mul taneousl y) i s added, the house can be run at under
2000 W peak al l the ti me.
Climatic Zone: Composite

4

Residence for Sudha and Atam Kumar, Delhi
There i s no need to use el ectri ci ty for space heati ng and cool ing,
nor for water heati ng. Usi ng a careful sel ecti on of devi ces, 15 A
ci rcui ts can be el i mi nated from the house al together.
Inverter and future provision of photovoltaic charging
The house has a central i nverter and a battery bank that can
provi de for 8 hours of emergency usage.
It i s pl anned that as soon as affordabl e, the house shal l be put on
photovol tai c chargi ng and progressi vel y made l ess dependent on
the gri d.
Renewable energy systems
Architecturally integrated solar hot water
A 200 l i tre-per-day hot water system i s archi tectural l y i ntegrated
wi th the house.
A sol ar water heater panel i s mounted verti call y on the south wal l
above the ki tchen. Thi s non-standard mounti ng angl e reduces the
probl ems of dust accumul ati on, endemi c to Del hi . It reduces
chances of breakage due to hai l or cats, etc. It al so frees up
terrace space and i s a techni que that coul d be used i n mul ti -
storeyed bui l di ngs to provi de i ndi vi dual hot water systems wi thout
usi ng the roof.
A rooftop i nsul ated hot water tank col l ects the sol ar heated water,
whi ch i s then avai l abl e to al l the toi l ets and ki tchen. A sensi tive
thermostat acti vates the back-up l ow-wattage el ectri cal el ement on
the eveni ng of cl oudy days, but onl y i f manual l y acti vated by the
resi dents.
An i ndependent 100 l i tre-per-day verti cal ly mounted sol ar hot water
system i s provi ded for the outhouse.
Built-in solar cooking
A sl i di ng sol ar cooker i s bui l t i nto the south wal l of the ki tchen.
The pans can be accessed from i nsi de the ki tchen and come out at
counter l evel for ease of use.
Climatic Zone: Composite

5

Residence for Sudha and Atam Kumar, Delhi
Bal ance cooki ng i s done wi th conventi onal fuel .
Waste recycling and water conservation
Compost pit
Two pi ts i n the garden can ensure the composti ng of ki tchen
wastes. The ki tchen, i n turn, i s provi ded wi th ampl e space bel ow
the counters to ensure separati on of paper, organi cs, and other
waste and recycl i ng of the fi rst two types.
Low water flushes
The house i s fi tted wi th fl ush val ves and wi thout any ci sterns.
Performance
The thermal systems general l y worked very wel l i n wi nter,
el i mi nati ng the requi rement of heavy qui lts al together.
The dry summer season performance was good except for sl i ght
dropl ets of water spi lli ng over from the wet pads of the cool i ng
tower i nto the stai rcase area.
Monsoon comfort i s dependent on strategi cal l y cl osi ng or openi ng
the wi ndows.
Renewabl e energy systems have worked wel l .
El ectri cal systems are sati sfactory, but hi ghl y stressed due to
errati c power suppl y and extreme vol tage fl uctuati ons i n the area.

At a glance
Project details
Project description Plotted house for a couple
Architect Sanjay Prakash
Sanjay Prakash & Associ ates
F - 25 Basement
Lajpat Nagar III
New Del hi - 110 024
Climate Composite
Climatic Zone: Composite

6

Residence for Sudha and Atam Kumar, Delhi
Consultants Atam Kumar (energy) Sunil Arora (structure)
Project period 1995-1996
Size 160 m covered area in a plot of 450 m
Client/Owner Atam Kumar
Promoter Cdr. C P Sharma (Retd)
Builder/Contractor Asian Townsville Farms Ltd

Design features
o The house has been oriented to face south so that every habitable
room has a liberal solar exposure. Shading has been carefully designed
to prevent solar gains during summer and allow the same during
winter
o External wall and roof insulation help the thermal mass to act in
tandem with the inner space
o Reflective finishes of wall and roof for heat reflection
o Multi-directional evaporative wind tower atop stairwell, for cooling of
house during dry summer
o South-facing solar chimneys assist air exhaust during summer
o Architecturally integrated solar water heating system and solar cooker
o Compost pits in garden for composting of kitchen wastes
o Low water flush valves without cisterns
o All rooms adequately day lit and artificial lighting provided with low
energy lights
o Overall rationalization of loads done by careful device selection
o An inverter and battery bank back-up has been provided with provision for
photovoltaic charging in future