0% found this document useful (0 votes)
142 views2 pages

Pengukuran New Coal Mill Tuban I (Atox)

The document summarizes measurements taken from a new coal mill (ATOX) at Tuban Power Plant on October 19, 2011 between 2-4pm. It records oxygen, carbon monoxide, carbon dioxide, temperature, pressure, flow rate and other metrics from the mill outlet, gas coming from two preheaters (TBN1 and TBN2), and the overall gas inlet. Gas was sampled from multiple locations and measurements were within normal ranges.

Uploaded by

TIRIANTO
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
142 views2 pages

Pengukuran New Coal Mill Tuban I (Atox)

The document summarizes measurements taken from a new coal mill (ATOX) at Tuban Power Plant on October 19, 2011 between 2-4pm. It records oxygen, carbon monoxide, carbon dioxide, temperature, pressure, flow rate and other metrics from the mill outlet, gas coming from two preheaters (TBN1 and TBN2), and the overall gas inlet. Gas was sampled from multiple locations and measurements were within normal ranges.

Uploaded by

TIRIANTO
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

PENGUKURAN NEW COAL MILL TUBAN I (ATOX)

Hari / Tanggal
Pukul

:
:

Selasa/ 19 Oktober 2011


14:00 - 16:00

Outlet Mill
O2 (%)

1262.00
12.31

Pressure(mmWg)
Temp (C)

-677.79
70.00

Area (m2)
Flow (m/s)
Flow (m3/h)
Flow (Nm3/h)

Gas From Preheater TBN 1


O2 (%)
3.86
CO (ppm)
4377.00
CO2 (%)
14.74
Velocity(m/s)
11.91
Pressure(mmWg)
-154.69
Temp (C)
395
Area (m2)
3.14
Flow (m3/h)
134,673
Flow (Nm3/h)
54,214
% GasTBN1
45.2

6.86

CO (ppm)
CO2 (%)
False Air

8.66%

4.37
196,009
145,774

Gas From Preheater TBN 2


O2 (%)
3.82
CO (ppm)
205.50
CO2 (%)
15.06
Velocity(m/s)
14.25
Pressure(mmWg)
-156.06
Temp (C)
385.00
Area (m2)
3.14
Flow (m3/h)
161,164
Flow (Nm3/h)
65,856
% GasTBN1
54.8

Gas Inlet
O2 (%)
CO (ppm)
CO2 (%)
False Air
Pressure(mmWg)
Temp (C)
Area (m2)
Flow False Air(Nm3/h)
Flow (Nm3/h)
Flow (m3/h)

5.64
705.00
13.42
11.73
-172.38
265.00
14,081
134,152
268,857

You might also like