Base Plate DesignMS601a

Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 3

DESIGN OF BASE PLATE FOR PIPE Column Pipe Section Height of Stanchion h = Ph1 = Ph2 = N = Dimension of Base Plate

D = Dia. Of anchor Bolt = Anchor Bolt capacity Tension = Grade of Concrete = Steel yield Strength = dt = dt /3 = d = M = e = Tension Force Effects :D/6 = = 0.108 m 0.128 m P406.00mm 6.20m 10.00 KN 10.00 KN 56 KN 0.650 m 0.030 m 65 KN 21 N/mm2 235 N/mm2 0.060 m 0.020 m 0.590 m 62.00 KN-m 1.107 m (pipe dia)

Inputs

(Friction force) (Wind force against Friction and structure) b = 0.650 m No of Anchor bolt in either dir. = Shear = 30 KN

(D/6 + dt/3)

3- Tension force affects (Anchor Bolts) c = 2N(e+D/2-dt) / (b.Xn(d-dt-Xn/3)), Z = N(e-D/2+Xn/3) x/d = x/d = r = r = Xn/d = Xn = So c1 = Z1 = (e-D/2) / d 1.326 at / (b.d) 0.006 0.4 (From Graph) 0.24 m 1.82 N/mm2 87.43 KN (Per 3 Anchor Bolts)

For

Ph2 = 10.00 KN M = 62.00 KN-m e = 1.107 m 3- Tension force affects (Anchor Bolts) c = 2N(e+D/2-dt) / (b.Xn(d-dt-Xn/3)), Z = N(e-D/2+Xn/3) x/d = Xn/d = Xn = c2 = Z2 = 1.326 0.45 (From Graph) 0.27 m 1.62 N/mm2 88.43 KN (Per 3 Anchor Bolts)

CHECKS 1- Compression Check of Concrete

(c1 + c2) / fc' = 2- Anchor Bolt Check

0.163

OK

i) Tension (Z1+Z2) /no. of bolt = 58.62 KN (Z1+Z2) /no. of bolt /(Anchor Bolt Tension Capacity) =

0.90

OK

ii) Shear ((Ph12 +Ph22) ^0.5 /8) /Anchor Bolt Shear Capacity 0.167 OK Combination of Anchor Bolt Shear force shall be checked 1.069 OK 3- Check Of Base Plate Thickness i) Compression

therefore Mx = My =

l = b = l/b =

172 mm 294 mm 0.584

0.06 c b2 -0.2728502 c l2 Mx = 8784.63 N-mm/mm My = -13003.16 N-mm/mm t = (6*Mmax / fb)^0.5 t = 20 mm

ii) Tension Z = bt2 / 6 b = Z = = Me / Z < fb M = (Z1+Z2) /3 fb = 0.66 fy 1.25 t > 51 mm TEFLON SHEET ARE USED

159 mm 27 t^2