0% found this document useful (0 votes)
120 views

Base Plate DesignMS601a

This document summarizes the design of a base plate for a pipe column. It provides the key dimensions, material properties, and calculations for checking the design. The base plate is designed to support a pipe with a height of 6.2 meters under wind loads of 10 kN. Calculations are shown for tension forces on the anchor bolts, compression in the concrete, and thickness of the base plate. All checks of the design are reported to pass requirements.

Uploaded by

duazo2009
Copyright
© © All Rights Reserved
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
120 views

Base Plate DesignMS601a

This document summarizes the design of a base plate for a pipe column. It provides the key dimensions, material properties, and calculations for checking the design. The base plate is designed to support a pipe with a height of 6.2 meters under wind loads of 10 kN. Calculations are shown for tension forces on the anchor bolts, compression in the concrete, and thickness of the base plate. All checks of the design are reported to pass requirements.

Uploaded by

duazo2009
Copyright
© © All Rights Reserved
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 3

DESIGN OF BASE PLATE FOR PIPE Column Pipe Section Height of Stanchion h = Ph1 = Ph2 = N = Dimension of Base Plate

D = Dia. Of anchor Bolt = Anchor Bolt capacity Tension = Grade of Concrete = Steel yield Strength = dt = dt /3 = d = M = e = Tension Force Effects :D/6 = = 0.108 m 0.128 m P406.00mm 6.20m 10.00 KN 10.00 KN 56 KN 0.650 m 0.030 m 65 KN 21 N/mm2 235 N/mm2 0.060 m 0.020 m 0.590 m 62.00 KN-m 1.107 m (pipe dia)

Inputs

(Friction force) (Wind force against Friction and structure) b = 0.650 m No of Anchor bolt in either dir. = Shear = 30 KN

(D/6 + dt/3)

3- Tension force affects (Anchor Bolts) c = 2N(e+D/2-dt) / (b.Xn(d-dt-Xn/3)), Z = N(e-D/2+Xn/3) x/d = x/d = r = r = Xn/d = Xn = So c1 = Z1 = (e-D/2) / d 1.326 at / (b.d) 0.006 0.4 (From Graph) 0.24 m 1.82 N/mm2 87.43 KN (Per 3 Anchor Bolts)

For

Ph2 = 10.00 KN M = 62.00 KN-m e = 1.107 m 3- Tension force affects (Anchor Bolts) c = 2N(e+D/2-dt) / (b.Xn(d-dt-Xn/3)), Z = N(e-D/2+Xn/3) x/d = Xn/d = Xn = c2 = Z2 = 1.326 0.45 (From Graph) 0.27 m 1.62 N/mm2 88.43 KN (Per 3 Anchor Bolts)

CHECKS 1- Compression Check of Concrete

(c1 + c2) / fc' = 2- Anchor Bolt Check

0.163

OK

i) Tension (Z1+Z2) /no. of bolt = 58.62 KN (Z1+Z2) /no. of bolt /(Anchor Bolt Tension Capacity) =

0.90

OK

ii) Shear ((Ph12 +Ph22) ^0.5 /8) /Anchor Bolt Shear Capacity 0.167 OK Combination of Anchor Bolt Shear force shall be checked 1.069 OK 3- Check Of Base Plate Thickness i) Compression

therefore Mx = My =

l = b = l/b =

172 mm 294 mm 0.584

0.06 c b2 -0.2728502 c l2 Mx = 8784.63 N-mm/mm My = -13003.16 N-mm/mm t = (6*Mmax / fb)^0.5 t = 20 mm

ii) Tension Z = bt2 / 6 b = Z = = Me / Z < fb M = (Z1+Z2) /3 fb = 0.66 fy 1.25 t > 51 mm TEFLON SHEET ARE USED

159 mm 27 t^2