Air System Sizing Summary For GDC-CONTROL-PCOSB 101
This document summarizes the air system sizing for an air handling unit serving a 17.5 square meter zone in Thai Binh, Vietnam. The central cooling coil is designed to handle a total load of 1400 kW and sensible load of 410 kW at design conditions of 37.2/36.7 degrees Celsius outdoor air. The central heating coil is designed for a maximum 0.2 kW load at a design heating temperature of 21.2 degrees Celsius. The supply fan is sized to deliver 308 liters per second of air to meet the peak cooling load. Outdoor ventilation is set at 18 liters per second or 1 liter per second per square meter for the zone.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
82 views1 page
Air System Sizing Summary For GDC-CONTROL-PCOSB 101
This document summarizes the air system sizing for an air handling unit serving a 17.5 square meter zone in Thai Binh, Vietnam. The central cooling coil is designed to handle a total load of 1400 kW and sensible load of 410 kW at design conditions of 37.2/36.7 degrees Celsius outdoor air. The central heating coil is designed for a maximum 0.2 kW load at a design heating temperature of 21.2 degrees Celsius. The supply fan is sized to deliver 308 liters per second of air to meet the peak cooling load. Outdoor ventilation is set at 18 liters per second or 1 liter per second per square meter for the zone.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1
Air System Sizing Summary for GDC-CONTROL-PCOSB 101
Project Name: THAI BINH - HAM RONG Prepared by: pve 04/11/2014 04:30PM
Air System Information
Air System Name Equipment Class Air System Type GDC-CONTROL-PCOSB 101 SPLT AHU SZCAV Number of zones Floor Area Location 1 17.5 m Thai Binh, Vietnam
Sizing Calculation Information
Zone and Space Sizing Method: Sum of space airflow rates Zone L/s Individual peak space loads Space L/s Calculation Months Sizing Data Jan to Dec Calculated
Central Cooling Coil Sizing Data
Total coil load Sensible coil load Coil L/s at Jun 1400 Max block L/s Sum of peak zone L/s Sensible heat ratio m/kW W/m Water flow @ 5.6 K rise 5.8 4.1 308 308 308 0.708 3.0 331.3 N/A kW kW L/s L/s L/s Load occurs at OA DB / WB Entering DB / WB Leaving DB / WB Coil ADP Bypass Factor Resulting RH Design supply temp. Zone T-stat Check Max zone temperature deviation Jun 1400 37.2 / 36.7 25.8 / 19.6 14.7 / 14.2 13.5 0.100 50 12.8 1 of 1 0.0 C C C C % C OK K
Central Heating Coil Sizing Data
Max coil load Coil L/s at Des Htg Max coil L/s Water flow @ 11.1 K drop 0.2 kW 308 L/s 308 L/s N/A Load occurs at W/m Ent. DB / Lvg DB Des Htg 13.4 21.2 / 21.9 C
Supply Fan Sizing Data
Actual max L/s Standard L/s Actual max L/(s-m) 308 L/s 307 L/s 17.59 L/(s-m) Fan motor BHP Fan motor kW Fan static 0.01 BHP 0.01 kW 10 Pa