0% found this document useful (0 votes)
44 views

Second Storey Slab Checking ( Worst Case)

This document calculates loadings and determines allowable imposed loadings for the critical case of the main building. It calculates dead loads and live loads for various floors and roof levels, including slabs, finishes, columns, walls, beams, and roof materials. The total dead load is calculated to be 681.57 kN and total live load is 164.07 kN. The total load of 776.54 kN is less than the allowable bearing capacity of the soil, which has a tested allowable pressure of 140 kN/m2 compared to the calculated pressure of 123.71 kN/m2. Therefore, the foundation design is determined to be acceptable.

Uploaded by

shaz333
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
44 views

Second Storey Slab Checking ( Worst Case)

This document calculates loadings and determines allowable imposed loadings for the critical case of the main building. It calculates dead loads and live loads for various floors and roof levels, including slabs, finishes, columns, walls, beams, and roof materials. The total dead load is calculated to be 681.57 kN and total live load is 164.07 kN. The total load of 776.54 kN is less than the allowable bearing capacity of the soil, which has a tested allowable pressure of 140 kN/m2 compared to the calculated pressure of 123.71 kN/m2. Therefore, the foundation design is determined to be acceptable.

Uploaded by

shaz333
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

Harvest

PART 1 :

CALCULATIONS OF LOADINGS AND DETERMINATION OF


ALLOWABLE IMPOSED LOADINGS

Taking Critical Case of Main Building


(1) Second Storey Slab Checking (** Worst Case)

ly/lx = 2.2,

One way slab (With Imposed loads of 4 KN/m2 )

Slab thickness = 150mm


d = 150-2(20)-2(10) = 90mm
Self Weight = 24 x 0.15 x 1m strip width = 3.6 kN/m
Service Dead Load = 0.75 kPa (assumed) x 1m strip width = 0.75 kN/m
Live Load = 4 KN/m2 (assumed) x 1m strip width = 4 kN/m
Wult = SW + SDL + LL = 8.35 kN/m
Mmax = WultL2/8 = 8.3 x 22 / 8 = 4.15 kNm
Assumed fcu = 20 N/mm2 (Concrete Characteristic Strength) Mild Steel of 250N/mm2
k = Mmax / fcubd2 = 4.15 x 106 / 20 x 1000 x 902 = 0.0256 < 0.156
Z = 90 { 0.5 + [0.25 (0.0256/0.9)]1/2 } = 87.4mm > 0.95d = 85.5mm
As(required) = 4.15 x 106 / 0.87 x 250 x 85.5 = 223 mm2
as scanned at the site
As(provided) = R12-225mm
= 5R12 = 565 mm2 > As(required) = 223 mm2 Ok, assumption correct

Harvest

PART 2 :

Checking of Main Building Foundation Loads


(All dimensions & structures are to be assumed
conservatively)

Elevation view

1st storey plan

Harvest

2nd storey plan

3rd storey plan

Harvest

(2a) First Storey:


(i) Dead Load:
Assume slab to be non-suspended slab
Floor finishes = 0.75 kPa (assumed) x (6/2 + 4/2) x (5.6/2 + 4.4/2) = 18.75 kN
Column = 0.45 x 0.4 x 4.75 x 24 =

20.52 kN

Brickwall = 20 x 0.175 x (6/2 + 4/2) x 4.75 =

83.13 kN
Total = 122.4 kN

(2b) Second Storey:


(i) Dead Load:
Slab = 0.15m (assumed) x 24 x (6/2 + 4/2) x (5.6/2 + 4.4/2) =

90 kN

Floor finishes = 0.75 kPa (assumed) x (6/2 + 4/2) x (5.6/2 + 4.4/2) =

18.75 kN

Column = 0.45 x 0.4 x 3.46 x 24 =

15 kN

Brickwall = 20 x 0.175 x (6/2 + 4/2) x (5.6/2 + 4.4/2) =

60.55 kN

Main Beam = 24 x 0.6m x 0.8m x (6/2 + 4/2) =

57.6 kN

Secondary Beam = 24 x 0.25 x 0.45 x (6/2 + 4/2) =

13.5 kN
Total = 255.4 kN

(ii) Live Load:


LL = 4 KN//m2 (assumed) x (6/2 + 4/2) x (5.6/2 + 4.4/2) =

100 kN

(2c) Third Storey or 2nd Upper Storey:


(i) Dead Load:
Slab = 0.15mm (assumed) x 24 x (6/2 + 4/2) x (5.6/2) =

50.4 kN

Beam = 24 x 0.6m x 0.8m x 6

69.1 KN

Floor finishes = 0.75 kPa (assumed) x (6/2 + 4/2) x (5.6/2) =

10.5 kN

Column = 0.45 x 0.4 x 3.06 x 24 =

13.22 kN

Brickwall = 20 x 0.175 x (6/2 + 4/2) x 3.06 =

53.55 kN
Total = 196.77 kN

nd

(ii) Live Load: (2

Upper Storey Rooms)

LL = 4 KN/m2 (assumed) x (6/2 + 4/2) x (5.6/2) =

50 kN

Harvest

(2d) Roof Level:


Brickwall = 20 x 0.175 x 1.81 x (6/2 + 4/2) =

32 kN

Service Dead Load


= 0.75 kPa (assumed) x (5.6/2 + 4.4/2) x (6/2 + 4/2) =

18.75 kN
Total = 50.75 kN

Roof Live Loads = 0.75KN/m2 x 5 x 5

14.07 KN

ROOF Materials = 1.5KN//m2 x 5 x 5

56.25 KN

Total Dead Load = 122.4 + 255.4 + 196.77 + 50.75 + 56.25 =

681.57 kN

Total Live Load = 100 + 50 + 14.07

164.07 kN

Total DL + LL = 776.54 kN
Strip Footing Size of 2m width (instead of 4m) x 4m (Span Length) x .75 Thk

Ground Footing Foundation Weight = 24.0 x 2 x 4 x .75 =

144.0 KN

Acting Soil Pressure = 989.64 / (2.0 x 4.0) = 123.71 KN//m2

Refer to Section 5.6 of the report, the tested foundation allowable bearing soil
pressure is 140.00 KN//m2 > 123.71 KN//m2 which is O.K.!

You might also like