SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF STEEL PIPES FOR WATER AND SEWAGE (168.3 to 2032 mm outside diameter) ACCORDING TO IS 3589:2001 (Incorporating Amendment No.1 to 3)
1.0 LABORATORY- A laboratory shall be maintained which shall be suitably equipped and
staffed, where different tests given in the specification shall be carried out in accordance with the methods given in the specification.
1.1 All testing apparatus shall be periodically checked and calibrated records of such
checks/calibration shall be maintained.
2.0 TEST RECORDS- All records of tests and inspection shall be kept in suitable forms approved by the Bureau. 2.1 Copies of any records and other connected papers that may be required by the Bureau shall be
made available at any time on request.
3.0 QUALITY CONTROL- It is recommended that, as far as possible, statistical Quality control (SQC) methods may be used for controlling the quality of the products during production as envisaged in this scheme (see IS 397 (part 1): 2003 IS 397 (part 2): 2003and IS 397 (part 3): 2003). 3.1 In addition, effort should be made to gradually to introduce Quality Management system in accordance with IS/ISO 9001:2000 4.0 STANDARD MARK The Standard Mark, as given in column (1) of the first schedule of the Licence, shall be applied at a suitable place on the outside surface of the pipe provided always that pipes so marked conform to all the requirements of the specification. 4.1 MARKING- In addition, following information shall be marked indelibly on the pipe: a) b) c) d) Manufacturers name or trade mark; Pipe designation; Outside diameter and specified wall thickness, Identification mark in code or otherwise to enable the date and lot of manufacture to be traced back to works records, and e) Licence number (CM/L..)
5.0 LEVELS OF CONTROL The tests, as indicated in Table 1 attached and at the levels of control specified therein, shall be carried out on the whole production of the factory which is covered by this scheme and appropriate records and charts maintained in accordance with paragraph 2.0 above. All the production, which conforms to the Indian Standards and covered by the Licence, shall be marked with BIS certification mark. 5.1 5.1 In respect of all other clauses of the specification and at all stages of manufacture the factory shall maintain appropriate controls and checks to ensure that their product conforms to the various requirements of the specification.
Table 1...
IS 3589:2001 STEEL PIPES FOR WATER AND SEWAGE (168.3 TO 2032 mm outside diameter) TABLE 1 LEVELS OF CONTROL (Para5 of the STI)
TEST DETAILS Clause 8 Requirement Clause
Chemical composition
No. of Samples
One
REMARKS
No chemical analysis is required for identified material received with test certificate and covered under BIS certification scheme. In case the sample fails, that hours production shall not be marked unless defective pipes are sorted out.
12
IS 3589:2001
One
One hour production of pipes of one particular size and steel grade
10.
-do-
Each pipe
9.1
Tensile Strength
IS:3589:2001
One
Each consignment of same thickness of skelp/plate, and size of pipes and day of production
Those found not conforming shall not be marked. NDT test may be carried out in place of hydraulic pressure test. Method for NDT and the acceptance level shall be as agreed to between the manufacturer and the purchaser. Incase the sample fails, two more such samples from different pipes shall be drawn and tested. In the event of any further failure the entire days production shall not be marked.
IS 3589:2001 SEAMLESS OR ELECTRICALLY WELDED STEEL PIPES FOR WATER AND SEWAGE (168.3 TO 2032 mm outside diameter) TABLE 1 LEVELS OF CONTROL (Para 5 of the STI)
TEST DETAILS Clause 9.2 9.2.1 Requirement
Flattening test or bend test Flattening test for ERW pipes 9.2.1 IS3589:2001 One a)Four hour production of one particular size & steel grade for pipes upto & including 350 mm OD Every four hours In case of failure of the samples, the whole lot of pipes represented by these samples shall be tested for test on weld and those found failing shall be rejected.
No. of Samples
REMARKS
b) 12 hrs production of one particular size & steel grade for pipes above 350mm OD upto & including 900 mm OD
Every 12 hours
-do-
9.2.3 9.3
Flattening Test for seamless pipes Guided Bend Test (for SAW Pipes)
9.2.3 9.3
-do-do-
One One
c) 24 hours production of one particular size & steel grade for pipes above 900 mm OD -do-do-
Every 24 hours
-do-
-do-do-
-do-do-
IS 3589:2001 SEAMLESS OR ELECTRICALLY WELDED STEEL PIPES FOR WATER AND SEWAGE (168.3 TO 2032 mm outside diameter) TABLE 1 LEVELS OF CONTROL (Para5 of the STI)
Clause 16 16.1 Requirement
Guideline of coating Protective coating if required
No. of Samples
One
REMARKS
-do-
In case the sample fails, the tubes represented by the sample shall not marked.
16.2
Galvanizing, if required
16.2
-doIS 4736
One
-do-
-do-
-do-
17
17
IS 3589:2001
One
Incase the sample fails that hours production shall not be marked.
14
14.1 to 14.5
-do-
Each pipe