Drilling Vibration Mitigation PDF
Drilling Vibration Mitigation PDF
Vib-Tor
Vib-Lat
Vib-X
CURES
STOP drilling, pickup off bottom and monitor the vibration date from downhole tool to make sure that all vibration energy has been dissipated before making any changes
Place top drive in high gear Ensure Soft Torque operational
YES
NO NO Pickup off bottom allow string torque to unwind Restart drilling with 70 RPM Increase WOB to target value Increase RPM to original value
Pickup off bottom allow string torque to unwind Restart drilling with 10% increased RPM Decrease WOB 15% to 20%
Pickup off bottom allow string torque to unwind Set RPM at 40-50% of original Increase WOB by 15-20% Gradually return RPM to original value
Vibration Resumes? Vibration Resumes? NO Pickup off bottom allow string torque to unwind Restart drilling with 70 RPM Increase WOB to target value Increase RPM to 25% of original value NO NO
Vibration Resumes?
Pickup off bottom allow string torque to unwind Restart drilling with 70 RPM Increase WOB 25% below original value Gradually return RPM to 15% above original value
Pickup off bottom Set RPM at 40-50% of original value Increase WOB by 15-20% Gradually return RPM to 25% below original
CONTINUE DRILLING
Fig. 8 Specific mitigating actions to be taken when S&V is encountered Part 2 of S&V Mitigation wall chart for display at the drilling site.