This document provides design details for a 400mm square reinforced concrete column resisting a vertical load of 2000kN and a bending moment of 250kNm. Key details include main reinforcement of H25 bars, links of H8 bars, and a cover of 30mm. The column is 4m high and supports a 300mm thick slab on a 7.5m grid. Using the PD 6687 method, the design moment is determined to be 290kNm. Reinforcement is designed as 4 H25 bars with H8 links at 200mm spacing. Second order effects do not need to be considered due to the column's slenderness being below the limit.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
121 views8 pages

Column Design

This document provides design details for a 400mm square reinforced concrete column resisting a vertical load of 2000kN and a bending moment of 250kNm. Key details include main reinforcement of H25 bars, links of H8 bars, and a cover of 30mm. The column is 4m high and supports a 300mm thick slab on a 7.5m grid. Using the PD 6687 method, the design moment is determined to be 290kNm. Reinforcement is designed as 4 H25 bars with H8 links at 200mm spacing. Second order effects do not need to be considered due to the column's slenderness being below the limit.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

Braced Column Design

2000kN
Design a 400 sq column resisting a vertical load
of 2000 kN and a moment of 250kNm.
250kNm

Assume the following:

Main reinforcement H25


Links H8
Cover 30mm
Column is 4.0m high
Supports 300mm thick slab on 7.5m grid
fck = 40MPa

h
d2

Braced Column Design

Braced Column Design

Using PD 6687 method

EIc
400 4 12
Lc
4000
k=
= 0.06
=
2EI b 2 2 7500 300 3 12

Lb
7500

F = 0.59 lo = 0.59 x 4.00 = 2.36m

Braced Column Design

M01 = Min {|Mtop |, | Mbot |} + ei Ned


M02 = Max {|Mtop |, | Mbot |} + ei Ned
ei = Max {lo/400, h/30, 20} (units to be in millimetres).
= Max {2360/400, 400/30, 20}
= Max {6, 13, 20} = 20
M01 = Min {250, 250} + 0.02 x 2000 = 290kNm
M02 = Max {250,250} + 0.02 x 2000 = 290kNm

Braced Column Design

Slenderness:
= 3.46 lo/h = 3.46 x 2.36/ 0.4 = 20.4
Slenderness limit:
Assume A=0.7, B = 1.1 and C=2.7

< lim
Second order effects do not need to be considered

Braced Column Design


Design moment:
M0Ed = M02 = 290kNm

M0Ed/(bh2fck) =
290 x 106 / (4003 x 40)
= 0.11

Ned/(bhfck) =
2000 x 103 / (4002 x 40)
= 0.31

d2/h = 50/400 = 0.125 < 0.15

0.13

Braced Column Design


Asfyk/bhfck = 0.13
As = 0.13 x 4002 x 40 / 500 = 1664 mm2
Use 4 H25 (1960 mm2) As = 1.2% Ac

> min 12
> As,min = 0,10NEd/fyd but 0,002 Ac
< As,max = 0.04 Ac

LINKS
Bar size:

(0,08Ac at laps)
150mm

25 / 4 = 6.25mm use H8
Maximum spacing, minimum of:
12 x 25 = 300mm

scl,tmax

60% x 400 = 240 mm


240 mm
Space at 200mm c/c

scl,tmax = 12 min; 60% b; 240mm

150mm

Biaxial Bending
a

NRd

MEdz MEdy
1,0

+
MRdz MRdy

a=2
NEd
a = 1.5

For rectangular cross-sections


NEd/NRd
0,1
0,7
1,0
a
1,0
1,5
2,0
where NRd = Acfcd + Asfyd

a=1

MEdy

For circular cross-sections

a = 2,0

MEdz

You might also like