STD C0001
STD C0001
STD C0001
( DATE)
NOTES:
1.
DIMENSION: UNLESS SHOWN OTHERWISE, ALL DIMENSIONS ARE IN MILLIMETRES.
12. DRAINAGE
MINIMUM FALL OF 1 IN 300 FOR ALL DRAINAGE PIPE OR AS TO REQUIRED CALCULATION. BACKFILL 0F 20mm SINGLE SIZE AGGREGATE TO A MINIMUM COVER OF 100mm ABOVE THE PIPE.
2.
STAUNCHION RAILWAY OVERHEAD STRUCTURE GUY LIGHT POLE POWER POLE ELECTRICITY PIT
( SI GNATURE)
PEDESTRIAN GATE, FENCING AND FOUNDATION DETAILS: FOR DETAILS AND SPECIFICATIONS RELATING TO PEDESTRIAN MAZE ENCLOSURE, ARRANGEMENTS, EQUIPMENT AND FOUNDATION DETAILS. REFER TO SHEETS 3, 4, 5 AND 6.
12.1
DRAINAGE PIPE ACROSS TRACKS CLASS 4 RCP PIPE OR EQUIVALENT AT MINIMUM DEPTH OF 1200mm FROM TOP OF RAIL TO TOP OF PIPE. RECOMMENDED MINIMUM PIPE SIZE OF 600mm FOR REGIONAL AREA.
12.2 3.
INSTALLATION & REFERENCE UNLESS NOTED OTHERWISE, INSTALLATION, SIGNAGE, UNSPECIFIED DIMENSIONS & ASSOCIATED WORKS SHALL BE IN ACCORDANCE WITH DRAWINGS / REFERENCES AS BELOW: 3.1 CRITERIA FOR INFRASTRUCTURE AT RAILWAY CROSSING - PEDESTRIAN CROSSINGS 3.2 MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES RAILWAY CROSSINGS 3.3 3.4 3.5 KERBS STANDARD FOR SIGNALLING DESIGN AND DOCUMENTATION SPECIFICATION FOR SIGNALLING SUPPLY, CONSTRUCTION AND INSTALLATION VICROADS SD 2001 VRIOGS 012.1 VRIOGS 012.2 AS1742.7 VRIOGS 003.2
DRAINAGE PIPE ALONG TRACK CLASS 3 RCP PIPE OR EQUIVALENT AT ABOUT 2700mm FROM RUNNING EDGE OF NEAREST RAIL AT DEPTH OF OPEN DRAIN, MINIMUM SIZE 225mm
12.3
SUB SURFACE DRAIN USE MEGAFLOW STRIP DRAIN, APPROX. SIZE 300 x 40 OR 100 -150mm ROUND SLOTTED FRC PIPE IN FILTER SOCK (BIDIM A14) OR APPROVED EQUIVALENT. BIDIM A14 MAY BE USED AS A SEPARATOR BETWEEN THE BALLAST AND THE DRAINAGE LINES. SUB SURFACE DRAIN TO BE CONNECTED TO EXISTING DRAINAGE PIPE, PIT OR RUN OFF TO NATURAL SURFACE. USE MINIMUM TO ROUND PIPE AS REQUIRED.
FLASHING LIGHTS
IRJ
INSULATED RAIL JOINT SIGNAL TELECOM POLE TELECOM PIT TELECOM PILLAR G & F VALVE STOP VALVE FIRE PLUG FIRE HYDRANT SIDE ENTRY PIT
4.
SIGNS & ROAD MARKING PAVEMENT MARKINGS & SIGNS SHALL BE SUPPLIED AND INSTALLED IN ACCORDANCE WITH AS1742.2, AS1742.7 & AS1743
( BL OCK L ETTERS)
5.
GRADES ALL PROPOSED PATHS TO BE GRADED NO STEEPER THAN 1:14. CROSS FALL TO BE PROVIDED FOR LEVEL PATHWAY, MAX. 1:40. ARROW FOR GRADE SHOWN ON DRAWING REPRESENTS DOWN DIRECTION.
SERVICES LEGEND
GUARD FENCE FENCE ON BOUNDARY
6.
TREATMENT OF RAILS RAILS THROUGH LEVEL CROSSING SHALL BE PAINTED WITH BITUMINOUS PAINT, TYPE 711 CHASSIS BLACK OR EQUIVALENT. COATINGS SHALL BE ON ALL SURFACES OF RAILS EXCEPT TOP AND RUNNING EDGE SURFACE. COATINGS TO EXTEND BEYOND THE PAVED AREA BUT MUST CEASE AT LEAST 1m FROM RAIL JOINTS.
Ce r t i f i e d By :
FENCE COMPRESSED AIR - ABOVE GROUND COMPRESSED AIR - UNDER GROUND DRAIN - ABOVE GROUND DRAIN - UNDER GROUND ELECRICITY - ABOVE GROUND ELECTRICITY - UNDER GROUND LOW VOLTAGE ELECRICITY - A. GROUND LOW VOLTAGE ELECTRICITY - U. GROUND HIGH VOLTAGE ELECRICITY - A. GROUND HIGH VOLTAGE ELECTRICITY - U. GROUND FUEL - ABOVE GROUND 9. 8.
7.
SERVICES UNDERGROUND SERVICES IF SHOWN ARE APPROXIMATE ONLY. SERVICES INFORMATION OBTAINED FROM "DIAL BEFORE YOU DIG" AT THE TIME OF DESIGN ACTUAL LOCATIONS ARE TO BE DETERMINED ON SITE PRIOR TO COMMENCEMENT OF WORK. RETAINING WALLS WHERE INDICATED, RETAINING WALLS TO BE PROVIDED IN ACCORDANCE WITH AS 4678, EARTH RETAINING STRUCTURES. BOLLARDS
FUEL - UNDER GROUND GAS - ABOVE GROUND GAS - UNDER GROUND CONCRETE HP GAS - UNDER GROUND OPTIC FIBRE - ABOVE GROUND OPTIC FIBRE - UNDER GROUND HP OIL - ABOVE GROUND HP OIL - UNDER GROUND PIPELINE - ABOVE GROUND PIPELINE - UNDER GROUND SERVICE DUCT SEWER - ABOVE GROUND SEWER - UNDER GROUND SIGNALS & COMMS SERVICE LINE - A.G. SIGNALS & COMMS SERVICE LINE - U.G. SIGNAL RODING ABOVE GROUND TELSTRA - LINE ABOVE GROUND
$ NAM E$
OR EQUIVALENT
50
MIN.
FOOTING
10. TACTILE GROUND SURFACE INDICATORS WHERE INDICATED, TGSIs TO BE PROVIDED IN ACCORDANCE WITH AS 1428.4. COLOUR: YELLOW, SIZE 300mm x 300mm MATERIAL: MASONRY FOR ASPHALT PAVEMENT, RUBBER FOR CONCRETE PAVEMENT. WHERE INDICATED, RAISED PAVEMENT MARKERS (R.P.Ms) TO BE PROVIDED IN ACCORDANCE WITH VRIOGS 003.2. 11. LIGHTING ADEQUATE LIGHTING TO BE PROVIDED BY COUNCIL / STAKEHOLDERS. ANY LIGHTING PROVIDED SHOULD BE IN ACCORDANCE WITH AS 1158.3.1 AND VRIOGS 003.2.
TELSTRA - UNDER GROUND SIGNALS TROUGHING - ABOVE GROUND SIGNALS TROUGHING - UNDER GROUND UNIDENTIFIED SERVICE WATER SUPPLY - ABOVE GROUND WATER SUPPLY - UNDER GROUND V/LINE Consultant
This drawing has been prepared by, or compiled from information provided by, persons other than Victrack. To the maximum extent permissible by law, Victrack takes no responsibility for, and makes no representations in relation to, the completeness, accuracy or quality of any information contained in this drawing. Each user of this drawing releases Victrack from all and any loss, damage, cost, expense or liability in relation to the use of, or any reliance on, this drawing or the information contained in it. All written dimensions take precedence over scaled dimensions.
3 0 0
MI N.
OPERATORS METRO
AUTHORISED BY
DATE
04/05/12 13/06/12
Designed By B.C. Ind. Review
$ TI M E$
coffey
Franchisee / Lessee
State Government
rail
01 of 06
$ DATE$
Revised By
In Serv
Rev.
Date
Description
Department of
<REDRAWN & REVISED. SUPERSEDES PLAN No. STD_R0012, STD_R0013, STD_R0014, STD_R0015, STD_R0017, STD_G0024, STD_C0012, STD_C0015, STD_C0016, STD_C0017, STD_C0018, STD_C0021, STD_C0022, F616, 117/2000>
Transport
This drawing is provided only for the information of the person or organisation to whom Victrack provides it. It may not be provided to, or used by, any other person without Victracks prior written consent.
STD_C0001
$FILE$
( DATE)
NOTES:
14.1 TRACK FOUNDATION DETAIL FOR PEDESTRIAN CROSSING SEE FLANGEWAY DETAIL 55 mm + 5 mm/-0 mm 1 IN 40 GRADE RECOMMENDED 1 IN 14 MAX. RUBBER PAVING UNITS
300
2000
C TRACK
F G H
J
BALLAST & EXISTING FORMATION
3 5mm +5mm/ 0mm
SLEEPER
0 N6 I 1
100 mm OF FULL DEPTH TYPE L ASPHALT
( SI GNATURE)
EXISTING SLEEPER
F
PIPE ALONG TRACK DRAIN ON BOTH SIDES OF RAIL TRACKS TO MATCH OPEN DRAIN. SEE NOTE 12.2 ON SHEET 1 EXTEND FULL DEPTH BALLAST TO PATH INTERFACE GEOFABRIC
25mm COMPACTED DEPTH ASPHALT SIZE 7 TYPE L CLASS C320 75mm COMPACTED DEPTH OF CLASS 2 F.C.R. CONSOLIDATED SUB-GRADE CBR GREATER THAN 5%
G H
DETAIL NTS
14.2 (b) FULL DEPTH ASPHALT PAVEMENT
7mm NOMINAL SIZE ASPHALT COMPACTED DEPTH FROM TOP OF RAIL TO TOP OF SLEEPER OVER FULL LENGTH OF SLEEPER, 2440mm WIDE & EDGE LINE R.P.Ms 170mm WIDE
1 -
( BL OCK L ETTERS)
2700 280 170 RAISED PAVEMENT MARKERS AS PER VRIOGS 003.2 INCORPORATED IN CONTRASTING LINE MARKING 1800 280 170 150 170
2440 150 1800 170 RAISED PAVEMENT MARKERS AS PER VRIOGS 003.2 INCORPORATED IN CONTRASTING LINE MARKING
PAINT SIDES AND FOOT OF RAIL WITH BITUMINOUS PAINT FOR CORROSION PROTECTION 60 mm + 5 mm/-0 mm
ASPHALT
3 5mm +5mm/ 0mm
ELEVATION
ELEVATION
Ce r t i f i e d By :
EXISTING SLEEPER
ASPHALT PAVEMENT
EPFLEX RAIL SEAL (METRO SITES) REFER TO DETAIL 3. BITUMINOUS PAINT (REGIONAL SITES) REFER TO DETAIL 2.
5 9 0
DETAIL NTS
2 -
ASPHALT PAVEMENT
ASPHALT
3 5mm +5mm/ 0mm
PLAN
PLAN
DETAIL NTS
$ NAM E$
3 -
Consultant
$ TI M E$
coffey
Franchisee / Lessee
State Government
rail
This drawing has been prepared by, or compiled from information provided by, persons other than Victrack. To the maximum extent permissible by law, Victrack takes no responsibility for, and makes no representations in relation to, the completeness, accuracy or quality of any information contained in this drawing. Each user of this drawing releases Victrack from all and any loss, damage, cost, expense or liability in relation to the use of, or any reliance on, this drawing or the information contained in it. All written dimensions take precedence over scaled dimensions.
02 of 06
$ DATE$
Revised By
In Serv
Rev.
Date
Description
Department of
<REDRAWN & REVISED. SUPERSEDES PLAN No. STD_R0012, STD_R0013, STD_R0014, STD_R0015, STD_R0017, STD_G0024, STD_C0012, STD_C0015, STD_C0016, STD_C0017, STD_C0018, STD_C0021, STD_C0022, F616, 117/2000>
Transport
This drawing is provided only for the information of the person or organisation to whom Victrack provides it. It may not be provided to, or used by, any other person without Victracks prior written consent.
STD_C0001
$FILE$
SIGN "G" 1830 CLEAR 1260 1200 HIGH SPRING LOADED GATE 1. ALL DIMENSIONS ARE IN MILLIMETRES. ALL DIMENSIONS ARE CENTRE POST TO CENTRE POST UNLESS SHOWN OTHERWISE. MINIMUM DISTANCE SHALL BE INCREASED TO ALLOW FOR CURVE EFFECTS WHEN TRACK RADIUS IS LESS THAN 600 m. 4. DESIGN LAYOUTS ARE BASED ON CURRENT VICTORIAN RAIL INDUSTRY OPERATORS GROUP STANDARDS VRIOGS 003.2. 5. 6. 7. SIGNS TO BE MANUFACTURED, SUPPLIED AND INSTALLED IN ACCORDANCE WITH VRIOGS 003.2, AS. 1742.2, AS. 1742.7 AND AS. 1743. SIGNS "B" AND "C" TO BE ANGLED TO FACE APPROACHING PEDESTRIANS. EMERGENCY ESCAPES TO HAVE 1000 WIDE SPRING LOADED GATE TO BE NORMALLY CLOSED AND OPEN ONLY IN DIRECTION INDICATED. 8. SPRING LOADED GATE: TOP HINGES TO BE TWO PART TYPE SIGN B & C
3 3 7 5
CLEAR
GENERAL NOTES:
2. 3.
8 1 0
SIGN E
1 0 0 0
1600 CLEAR
1600 CLEAR
400
( SI GNATURE)
390
1 7 0 0 3 0 0
WARNING:TGSI
5 1 8 5 1 7 0 0 3 0 0
1000 CLEAR
600 x 1500
1 0 0 0
SIGN D
SIGN D
8 1 0
(DOWNEE H4025 OR EQUIVALENT). BOTTOM HINGES TO BE HINGE PINS TYPE (DOWNEE HP25-SC OR EQUIVALENT). GATE CATCH TO BE PIPE POST CATCH TYPE (DOWNEE PP2540 OR EQUIVALENT) 9. CONCRETE FOOTINGS: CONCRETE FOOTING FOR ALL GATE AND STOP POSTS TO BE 400 DIA. x 600 DEEP. CONCRETE FOOTINGS FOR ALL FENCE POSTS TO 230DIA. x 600 DEEP. BASE PLATES FOR EACH POST TO BE FIXED TO FOOTINGS WITH 4 No. 12 DIA. D12058 DYNA BOLTS OR EQUIVALENT. 10. 11. MOTOR UNIT, GATE AND STOP POST TO BE SUPPLIED IN ACCORDANCE WITH MAGNETIC AUTO CONTROL "MRG METRAIL GATE" SPECIFICATIONS. PART OR ALL PARTS OF THE END POSTS FACING THE RAILS TO BE PAINTED OR MARKED TO PROVIDE A CLEAR LUMINANCE CONTRAST WITH THE BACKGROUND. YELLOW PAINT OR CHEVRON HAZARD MARKING IS DEEMED TO COMPLY WITH THIS REQUIREMENT. 12. ASPHALT PAVING TO BE EXTENDED 100 mm BEYOND MAZE FENCE LINES. MINIMUM DISTANCE SHOULD BE INCREASED TO ALLOW FOR CURVE EFFECTS WHEN THE TRACK RADIUS IS LESS THAN 600 m. 14. CRIB FENCING TO BE OFFSET FROM BOOM BARRIER MAST/FLASHING LIGHT MAST @ 2000 mm MIN. PEDESTRIAN CROSSING MAZE ENCLOSURE FENCING SHALL NOT BE POSITIONED LESS THAN 2 m FROM THE CENTRE LINE OF BOOM BARRIER/FLASHING LIGHT MAST FOUNDATION. 15. 13.
SIGN B & C
3 3 7 5
1226
0 0 5 E 1 T A G
1 1 6 7 5
1 5 0 G A 0 T E
CLEAR
2 SIGN F -
( BL OCK L ETTERS)
ASPHALT PAVEMENT
REFER TO 1 5 0 0MI N NOTE 3 NOTE 3
CLEAR 1010
OUTSIDE OF RAIL
Ce r t i f i e d By :
SIGNAGE NOTES:
1. 2. REFER TO AS 1743 FOR SIGN DETAILS. REFER TO AS1742.2 APPENDIX C FOR ILLUMINATION AND REFLECTORIZATION REQUIREMENTS FOR SIGNS.
X TRACKS
5 2 5
2025
1 9 0 0
WAYS
1 3 5 0
SIGN A OR B
SIGN A
X DENOTES NUMBER OF TRACKS
SIGN B
X DENOTES NUMBER OF TRACKS
SIGN C
2250
1700 CLEAR
SIGN D
1 8 2 5
1800 CLEAR
2150
1 3 5 0
SIGN C
EMERGENCY
5 2 5
EXIT
NO
REFER TO
WARNING:TGSI
NOTE 3
1 5 0 0MI N
THOROUGHFARE
600 x 1500
SIGN E
OUTSIDE OF RAIL
$ NAM E$
1800 CLEAR
1800 001 050. 1800 013 007. NUMBERS TO BE VERIFIED WITH THE INFRASTRUCTURE MANAGER
coffey
Franchisee / Lessee
State Government
rail
03 of 06
Revised By
In Serv
Rev.
Date
Description
Department of
<REDRAWN & REVISED. SUPERSEDES PLAN No. STD_R0012, STD_R0013, STD_R0014, STD_R0015, STD_R0017, STD_G0024, STD_C0012, STD_C0015, STD_C0016, STD_C0017, STD_C0018, STD_C0021, STD_C0022, F616, 117/2000>
Transport
This drawing is provided only for the information of the person or organisation to whom Victrack provides it. It may not be provided to, or used by, any other person without Victracks prior written consent.
STD_C0001
$FILE$
( DATE)
50 x 50 x 1.6 GALV. SHS FENCE POST 200 200 x 200 x10mm GALVANISED MILD STEEL PLATE 25 89 x 89 x 6 SHS GATE POST 89 x 89 x 6 SHS GATE POST 200 x 200 x10mm GALVANISED MILD STEEL PLATE 200 25 89 x 89 x 6 SHS GATE POST 353 MODIFIED TO ALLOW MOTOR ARM TO OPERATE
GATE
4 0 8
GATE
4 0 8
PROTECTIVE POST TO
( SI GNATURE)
DRILL & TAP 3 M6 HOLES IN GATE MOTOR BRACKET & FENCE DRILL & TAP 4 M6 HOLES IN FENCE &
GATE MECHANISM
GATE MECHANISM
DETAIL
DETAIL
( BL OCK L ETTERS)
TRIM WELDMESH FENCE TO NOTE: MOTOR UNIT, GATE AND STOP POST TO BE SUPPLIED IN ACCORDANCE WITH MAGNETIC AUTO CONTROL MRG METRAIL GATE SPECIFICATIONS. ALLOW MOTOR ARM TO OPERATE
SECTION
A REFER DETAIL 1
90
Ce r t i f i e d By :
1600 90
665
70
CLARITY
5 5
1 5 5
9 0
2 2 0 3 4 0
3 2
450 340
90 1500
1 0 0
1 6 0 0
3 5 0
OPEN POSI TI ON
5 2 5
0 0 . 0 9 R O F D E R R E F E R P N G I S E D
GENERAL NOTES:
1.
1 1 0 1 2 0 0 1 5
70 EMERGENCY ESCAPES TO HAVE 1000 GATE SPRING LOADED TO BE NORMALLY CLOSED AND OPEN ONLY IN DIRECTION INDICATED. 2. SPRING LOADED GATE: TOP HINGES TO BE TWO PART TYPE (DOWNEE H4025 OR EQUIVALENT). BOTTOM HINGES TO BE HINGE PINS TYPE (DOWNEE HP25-SC EQUIVALENT). GATE CATCH TO BE PIPE POST CATCH TYPE (DOWNEE PP2540 OR EQUIVALENT) SCALE 1:10
$ NAM E$
3.
CONCRETE FOOTINGS: CONCRETE FOOTING FOR ALL GATE AND STOP POSTS TO BE 400 DIA. x 600 DEEP. CONCRETE FOOTINGS FOR ALL FENCE POSTS TO 230DIA. x 600 DEEP. BASE PLATES FOR EACH POST TO BE FIXED TO FOOTINGS WITH 4 No. 12 DIA. D12058 DYNA BOLTS OR EQUIVALENT.
SCALE 1:15 4.
MOTOR UNIT, GATE AND STOP POST TO BE SUPPLIED IN ACCORDANCE WITH MAGNETIC AUTO CONTROL MRG METRAIL GATE SPECIFICATIONS.
Consultant
$ TI M E$
coffey
Franchisee / Lessee
State Government
rail
This drawing has been prepared by, or compiled from information provided by, persons other than Victrack. To the maximum extent permissible by law, Victrack takes no responsibility for, and makes no representations in relation to, the completeness, accuracy or quality of any information contained in this drawing. Each user of this drawing releases Victrack from all and any loss, damage, cost, expense or liability in relation to the use of, or any reliance on, this drawing or the information contained in it. All written dimensions take precedence over scaled dimensions.
04 of 06
$ DATE$
Revised By
In Serv
Rev.
Date
Description
Department of
<REDRAWN & REVISED. SUPERSEDES PLAN No. STD_R0012, STD_R0013, STD_R0014, STD_R0015, STD_R0017, STD_G0024, STD_C0012, STD_C0015, STD_C0016, STD_C0017, STD_C0018, STD_C0021, STD_C0022, F616, 117/2000>
Transport
This drawing is provided only for the information of the person or organisation to whom Victrack provides it. It may not be provided to, or used by, any other person without Victracks prior written consent.
STD_C0001
$FILE$
( DATE)
200x75 - 1800 LONG TREATED REFER TO SHEET 2 FOR FENCE POST SPACING BOLTS PER SLEEPER PINE SLEEPER
THE STEEL POST RETAINING WALL IS INDICATIVE OF A PREFERRED 1800 MAX 200x75 - 1800 LONG (MAX) 100 UC15 - 1200 LONG STEEL POSTS
( SI GNATURE)
ARRANGEMENT. THE FOLLOWING MUST BE CONSIDERED FOR THE DESIGN OF A STEEL POST RETAINING WALL: FOUNDATION SOIL CONDITIONS BACKFILL MATERIAL QUALITY AND COMPACTION DESIGN SURCHARGE POSTS SITE PROFILE IN FRONT OF AND BEHIND THE WALL
SCALE 1:20
MI N EM BEDM ENT 7 0 0
5 0 0 M AX HEI GHT
100 UC15 - 1200 LONG GALVANISED STEEL POSTS AT 1800 CENTRES (MAX)
THESE CRITERIA WILL CONFIRM DIMENSIONS AND ARRANGEMENTS WHEN THE DESIGN IS UNDERTAKEN BY A SUITABLY QUALIFIED ENGINEER.
( BL OCK L ETTERS)
300
1
1 2 0 0
SCALE 1:20
Ce r t i f i e d By :
GENERAL NOTES
1. 2. ALL DIMENSIONS ARE IN MILLIMETRES. UNLESS SHOWN OTHERWISE, FENCE DIMENSIONS ARE TO THE FENCE CENTRELINE OR CENTRE OF FENCE POSTS. 3. WELDMESH FENCING TO BE PROVIDED FOR 30m EACH SIDE OF PEDESTRIAN CROSSING WHERE EXISTING BOUNDARY FENCING HAS BEEN REMOVED.
6 0 0MI N 7 5 M AX
NSL
4 3
MASS CONCRETE
DESCRIPTION CAP (PRESS ON TYPE) 50mm 8 x 64 HEX GALV. BOLT U TYPE GALV. PANEL CLIP
50mm x 1.6mm
4 2
GALV. SHS
100
PATHWAY
3 B -
3 B PAVEMENT LEVEL
1 1:2 FILL BATTER OR AS APPROVED 2 MIN 75mm THICKNESS CLASS 2 20mm NOM. SIZE CRUSHED ROCK
PLAN
MIN 100 x 25 TIMBER EDGING
$ NAM E$
CORNER PLAN
B -
Consultant
$ TI M E$
coffey
Franchisee / Lessee
State Government
rail
This drawing has been prepared by, or compiled from information provided by, persons other than Victrack. To the maximum extent permissible by law, Victrack takes no responsibility for, and makes no representations in relation to, the completeness, accuracy or quality of any information contained in this drawing. Each user of this drawing releases Victrack from all and any loss, damage, cost, expense or liability in relation to the use of, or any reliance on, this drawing or the information contained in it. All written dimensions take precedence over scaled dimensions.
05 of 06
$ DATE$
Revised By
In Serv
Rev.
Date
Description
Department of
<REDRAWN & REVISED. SUPERSEDES PLAN No. STD_R0012, STD_R0013, STD_R0014, STD_R0015, STD_R0017, STD_G0024, STD_C0012, STD_C0015, STD_C0016, STD_C0017, STD_C0018, STD_C0021, STD_C0022, F616, 117/2000>
Transport
This drawing is provided only for the information of the person or organisation to whom Victrack provides it. It may not be provided to, or used by, any other person without Victracks prior written consent.
STD_C0001
$FILE$
1 2 9 5
WELDMESH FENCING
7 5
( DATE)
REFER TO FENCE AND HANDRAIL SCHEDULE FOR HANDRAIL AND CONNECTION MATERIALS. REFER TO NOTE 3. EQUIVALENT. AS REQUIRED. 50 x 1.6 GALV. SHS POSTS (TYP) ROLLED TOP AND BOTTOM GALVANISED ARC
No. 1 2 3
DESCRIPTION CAP (PRESS ON TYPE) 50mm x 50mm 8 x 64 HEX GALV. BOLT OR EQUIVALENT U TYPE GALV. PANEL CLIP
L MAX
( SI GNATURE)
3 -
1 2 0 0
8 6 5MI N -9 0 0 M AX
CFW
5 MIN
( BL OCK L ETTERS)
PAVEMENT
7 5
LEVEL
7 5
HANDRAIL
6 0 0MI N 7 5 M AX
100 BRACKET
7 5
7 5
SCHEDULE)
7 5
CONTINUATION
BRACKET: BAR BENT TO 90 ANGLE. SHOP FILLET WELD TO POST PRIOR 2 TO GALVANISING
L 4.09 3.81 3.58 3.37 3.18 3.01 2.86 1050 1100 1200 1250 1350 1400 1500
HANDRAIL
BEND
F.S.L.
R.75
OR CONTINUATION
CAPING PLATE
SECTION
SCALE 1:5
C -
NOTES:
1. 2. 3. USE POST SPACING OF STEEPER GRADE FOR INTERMEDIATE GRADES. MAXIMUM GAP BETWEEN BOTTOM OF THE WELDMESH FENCE AND FINISHED SURFACE IS 75mm HAND RAIL REQUIRED AS PER DSAPT AND AS 1428.2
Consultant
$ TI M E$
7 5 M AX
coffey
Franchisee / Lessee
State Government
rail
This drawing has been prepared by, or compiled from information provided by, persons other than Victrack. To the maximum extent permissible by law, Victrack takes no responsibility for, and makes no representations in relation to, the completeness, accuracy or quality of any information contained in this drawing. Each user of this drawing releases Victrack from all and any loss, damage, cost, expense or liability in relation to the use of, or any reliance on, this drawing or the information contained in it. All written dimensions take precedence over scaled dimensions.
06 of 06
$ DATE$
Revised By
In Serv
Rev.
Date
Description
Department of
<REDRAWN & REVISED. SUPERSEDES PLAN No. STD_R0012, STD_R0013, STD_R0014, STD_R0015, STD_R0017, STD_G0024, STD_C0012, STD_C0015, STD_C0016, STD_C0017, STD_C0018, STD_C0021, STD_C0022, F616, 117/2000>
Transport
This drawing is provided only for the information of the person or organisation to whom Victrack provides it. It may not be provided to, or used by, any other person without Victracks prior written consent.
STD_C0001
$FILE$