How To Configure DH+ Between Panelview Plus and Slc504 Using 2711P-Rn6

1. Create an application in the SLC504 processor to communicate with PanelView Plus over Ethernet. Download the application to the processor. 2. Create a PanelView Plus application and configure the Ethernet communication between the PC and SLC504. Test a numeric display and input. 3. Set up the Ethernet communication between PanelView Plus and SLC504 and download the application to PanelView Plus using a transfer utility over the Ethernet connection. Connect PanelView Plus and SLC504 using an Ethernet cable to run the application.

Uploaded by

for_c
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
60 views6 pages

How To Configure DH+ Between Panelview Plus and Slc504 Using 2711P-Rn6

1. Create an application in the SLC504 processor to communicate with PanelView Plus over Ethernet. Download the application to the processor. 2. Create a PanelView Plus application and configure the Ethernet communication between the PC and SLC504. Test a numeric display and input. 3. Set up the Ethernet communication between PanelView Plus and SLC504 and download the application to PanelView Plus using a transfer utility over the Ethernet connection. Connect PanelView Plus and SLC504 using an Ethernet cable to run the application.

Uploaded by

for_c
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 6

How to configure DH+ between PanelView Plus and SLC504 using 2711P !

"#
If you dont have 1784-PKTX card or PCMK card, you are still a le to confi!ure Panel"ie# Plus tal$in! to %&C'(4 thru )*+ net#or$, *ere is the e-a./le,

1,Create a 0%&o!i-'(( a//lication the /rocessor - &in$ %&C'(4 to your PC usin! 123)41-1 - Create a 0%&o!i-'(( a//lication, #e #ill 5ust use 677( address, )o#nload the a//lication to the /rocessor, - &eave %&C'(4 in runnin!, 8o to 0%&in- and delete 123)41-1 9,Create a 0%"ie# M: a//lication - &in$ PC to %&C'(4 usin! 0%9;9 cross-over ca le - &aunch 0%"ie# M: < )ou le clic$ =Co..unication %etu/> < Create a ne# confi!uration, - ?nder &ocal ta , add )41 driver and confi!ure it as follo#in! screens

- Create a shortcut and /oint to the %&C'(4 under )41 driver

Create a ne# dis/lay, /ut a nu.eric dis/lay and a nu.eric in/ut o 5ects on it, Ma$e sure to connect 677(, %ave the dis/lay as =Test>

- Test the dis/lay and .a$e sure you can in/ut and dis/lay 677( data

- ?nder Start, do follo#in! settin!s7

- 2ac$ Co..unication setu/ screen < Tar!et ta < 1dd driver and choose )*+ @1784-PKTX, 9711-06A, 9711068B < CK

- )river selection is follo#ed y a dialo! that lets you set the drivers 6a.e, the ada/ters %tation I) and Du./er I), and the net#or$ 2aud rate7

This sa.e confi!uration dialo! can e .odified later, y doin! a 0i!ht clic$ on the )river /ro/erties, - 6o# add the /rocessor eneath that ada/ter7 0i!ht clic$ )*Plus, )*+ < 1dd device < Choose relevant /rocessor < CK

- 0e-/oint the shortcut na.e to the /rocessor a!ain, 2e sure, this ti.e you define the =/ointer> in Tar!et ta

;, )o#nload a//lication to Panel"ie# Plus - ?se a strai!ht thru ca le to lin$ PC and Panel"ie# Plus - ?nder co..unication setu/ < &ocal Ta < 0i!ht clic$ )41 < Pro/erties

- *it CK and you should e a le to see Panel"ie# Plus @a PC iconB

Create a runti.e a//lication ?se Transfer ?tility to do#nload the a//lication to P"P thru )41 drive

Connect Panel"ie# Plus and %&C'(4 usin! )*+ ca le Ehen do#nloadin! finishes, load the a//lication and run it, PanelView Plus 0IC ;, 2lue 9, %hield 1, Clear SLC504 )*+ 1, 2lue %hield 9, Clear

4,Ca le connection )*+ ;, Clear 9, %hield 1, 2lue