Tower1 sht2

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

NOTE : 1. ALL DIMENSIONS ARE IN MM AND LEVELS ARE IN METER. UNLESS MENTIONED OTHERWISE. 2. NO DIMENSIONS SHALL BE SCALED OUT. ONLY FIGURED DIMENSIONS ARE TO BE TAKEN. 3. GRADE OF CONCRETE IS M-25 AS PER I.S.456-2000 4. GRADE OF REINFORCEMENT IS Fe500 (TMT BAR) CONFORMING TO I.S. 1786-2008 5. CLEAR COVER TO REINFORCEMENT FOR (i) BEAM-25mm. (ii) SLAB-20mm.

A
1150

B
3725

C
3500

D
3125

E
2150

G
2150

H
3125

I
3500

J
3725

K
1150

1050

1
300 2525 3-16 ALTH. 300

6. ASSUMED VERTICAL LOAD CARRYING CAPACITY OF PILE= 175 T

3-16
450

ALTH.

7. BACK FILLING OF FOUNDATION AND PLINTH FILLING SHOULD BE DONE WITH COMPACTED FINE SAND.

450

1100

2L-8

@100 C/C

2L-8 3-16
AT MIDSPAN

@ 150 C/C ALTH.

3-16 1525 AT SUPPORT

ALTH.

4
1375

TYPICAL R.C.DETAILS OF TIE BEAM


SCALE: 1:20

5
2250

6 7 8
12 2250 8 8 1375 @ 200 C/C @150 C/C @ 200 C/C 1262 1262

9 10
1525 12 8 @150 C/C

0 60

1100

11 12

@ 200 C/C

0 60

@ 200 C/C

0 15
12 @150 C/C 300 3-16 8 @ 200 C/C 450 2L-8 @100 C/C ALTH.
CERTIFICATE OF THE STRUCTURAL ENGINEER/CIVIL ENGINEER : CERTIFIED THAT THE STRUCTURAL DRAWING & DESIGN OF BOTH THE FOUNDATION AND SUPERSTRUCTURE OF THE BUILDING HAS BEEN MADE CONSIDERING THE SOIL TEST REPORT AS PER THE RULES AND REGULATIONS MADE UNDER THE ACT AND ALSO CONSIDERING ALL POSSIBLE LOADS,WIND LOADS, SEISMIC LOAD AND THE MOMENTS GENERATED BY THE PROPOSED STRUCTURE AS PER THE BUREAU OF INDIAN STANDARD & NATIONAL BUILDING CODE OF INDIA & CERTIFIED THAT IT IS SAFE AND STABLE IN ALL RESPECT AND THESE PROVISIONS SHALL BE ADHERED TO DURING THE CONSTRUCTIONS.

2525

PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

13
12

@ 200 C/C

@150 C/C

TYPICAL R.C.DETAIL OF STAIRCASE


SCALE-1:25 3-16 ALTH.

COLUMN LAYOUT PLAN


SCALE- 1:100

TYPICAL R.C. DETAIL OF LANDING BEAM


SCALE: 1:20

A
1150

B
3725

C
3500

D
3125

E
2150

G
2150

H
3125

I
3500

J
3725

K
1150

L
300 3-20 ALTH. EXT. 450 2L-8 2-20 3-20 AT SUPPORT ALTH. AT MIDSPAN 3-20 @150 C/C EXT. ALTH.
I CERTIFY THAT ALL THE ARCHITECTURAL DRAWINGS HAVE BEEN PREPARED BY ME COMPLYING WITH THE PLANNING AREA(BUILDING OPERATIONS) RULES,2009. I SHALL BE HELD RESPONSIBLE IF ANY INCORRECT INFORMATION IS FURNISHED BY ME OR ANY VIOLATION OF THE PROVISIONS OF THESE RULES AND THE PLANNING AREA(BUILDING OPERATIONS)REGULATIONS,2009 IS FOUND IN ANY OF THE DRAWINGS & DOCUMENTS,SIGNED BY ME AND SUBMITTED TO THE SANCTIONING AUTHORITY FOR OBTAINING SANCTION.

1050

300 3-20 ALTH.


CERTIFICATE OF THE ARCHITECT :-

SIGN. OF STRUC. ENGINEER :

1 B1
2525

3-20

B1 B2 B3 B2 B1 B1 B2 B3 B2 B3 B1 B3 B1 B2 B2 DN UP B1 B1 B2 B2 B1 B1 B1 B3 B3 B3 B2 B3 B1

450

2L-8

@100 C/C

B1

B3

1100

TYPICAL CROSS SECTION OF B1


1525 SCALE: 1:20

B3 B3 B2 B3

4 5
2250 1375

300 3-25 2-20 450 ALTH. EXT. @100 C/C ALTH. 450

300 3-25 ALTH.

SIGN. OF ARCHITECT :

6
1262

B1 B1 B1 B1

B1 B1 B1 DN B1 UP B1 B1 B1 B1 B1

B1 B1 B1 B1

2L-8

@150 C/C

2L-8 3-25 AT SUPPORT

7
1262

3-25 AT MIDSPAN

ALTH.

8
2250

TYPICAL CROSS SECTION OF B2


B2 B2 B3 B3 B3 B2
SCALE: 1:20

9 10
1525 1375

B2 B3 B3 B3 B3 B2 B1
2525

B2

B2

AUTHORIZED SIGNATORY

300

300 3-25 ALTH. 3-25 ALTH.

B1

B1

B1

B1

B3
450

1100

11 12

450

B2 B3 B2 B1 B1 B2 B3 B3 B1

2L-8

@100 C/C

2L-8

@150 C/C

PROJECT :
3-25 AT SUPPORT ALTH. AT MIDSPAN 1. SLAB THICKNESS IS 150 mm. UNLESS MENTIONED OTHERWISE. 2. ALL SLAB REINFORCEMENT ARE 8 @ 150 C/C 3-25 ALTH.

B3

PROPOSED G+19 STORIED RESIDENTIAL BUILDING PROJECT FOR MEGHOBIHAR CO-OPERATIVE HOUSING SOCIETY LTD. AT PREMISES NO.05-0622, PLOT NO. 12 / 1 IN AA-IIB, NEW TOWN, KOLKATA.
DATE TITLE : GENERAL ARRANGEMENT AND R.C.DETAILS OF TIE BEAM, FLOOR BEAM AND STAIRCASE
SCALE

13 B1 B1

TYPICAL CROSS SECTION OF B3


SCALE: 1:20

DSGN. DRWN. CHKD. APPD.

NAME S.AUDDY K.AMIN D.MAJUMDAR D.MAJUMDAR

AS SHOWN
DATE

6.10.2012

16.10.2012
SIZE REV.

TYPICAL FLOOR BEAM LAYOUT PLAN


SCALE- 1:100

DRG. No.

2
PRELIMINARY TENDER INFORMATION STRUCTURAL APPROVAL ELECTRICAL

A1

RELEASED FOR DRAWING STATUS

CONSTRUCTION PLUMBING

ARCHITECTURAL

PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

You might also like