0% found this document useful (0 votes)
27 views1 page

Foundation Degree: Industrial Control: Green Outputs Respectively

The document provides instructions for three tasks to write relay ladder logic programs: 1) A program for a TON timer to control three outputs based on the timer's status bits. 2) A start/stop control program using inputs and outputs. 3) A traffic light control program using three TON timers with different preset times to control red, amber, and green lights. The tasks require writing and testing the programs, and producing hard copies of the ladder diagrams.

Uploaded by

sjmarais
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
27 views1 page

Foundation Degree: Industrial Control: Green Outputs Respectively

The document provides instructions for three tasks to write relay ladder logic programs: 1) A program for a TON timer to control three outputs based on the timer's status bits. 2) A start/stop control program using inputs and outputs. 3) A traffic light control program using three TON timers with different preset times to control red, amber, and green lights. The tasks require writing and testing the programs, and producing hard copies of the ladder diagrams.

Uploaded by

sjmarais
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 1

Foundation Degree: Industrial Control Write programs using logic functions based on relay ladder logic.

Task 1(a): Task 1(b): Task 1(c): Write a relay ladder logic program for TON timer. Your program is to use XIC instructions, and the timer should be appropriately addressed with the time base and preset values. Use the timer control bits to drive three outputs. Comment on your program operation and particularly on the status of the control bits (timer enable, timer timing and timer done) as the program progresses and finishes Test your program and produce a hard copy of the ladder diagram. Write a relay ladder logic program for start/stop control. Your program is to use XIC instructions, and to have appropriate input/outputs addresses. Comment on program operation. Test your program and produce a hard copy of the ladder diagram.

Write a relay ladder program for a traffic light control application. Use different preset values for each of the three TON timers. Give the three outputs, timing ratios of 3, 2 and 5 for the red, amber and green outputs respectively. Make use of XIC and XIO instructions in your program. Test your program and produce a hard copy of the ladder diagram.

You might also like