2.488Gbps SFP Optical Transceiver, 2km Reach: DS-SFP-FC-2G-LW

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

www.huihongfiber.com sales@huihongfiber.

com
DS-SFP-FC-2G-LW
2.488Gbps SFP Optical Transceiver, 2km Reach

Features
Up to 2.488Gb/s bi-directional data links
1310nm FP laser and PIN photodetector for 2km transmission
Compliant with SFP MSA and SFF-8472 with duplex LC receptacle
Digital Diagnostic Monitoring:
Internal Calibration or External Calibration
Compatible with RoHS
+3.3V single power supply
Operating case temperature:
Standard : 0 to +70C
Industrial : -40 to +85C

Applications
SDH STM-16 and SONET OC-48 system
2X Fiber Channel
Switch to Switch interface
Switched backplane applications
Router/Server interface
Other optical transmission systems

Description
The SFP transceivers are high performance, cost effective modules supporting dual data-rate of
2.488Gbps and 10km transmission distance with SMF.

The transceiver consists of three sections: a FP laser transmitter, a PIN photodiode integrated with
a trans-impedance preamplifier (TIA) and MCU control unit. All modules satisfy class I laser safety
requirements.

The transceivers are compatible with SFP Multi-Source Agreement (MSA) and SFF-8472. For
further information, please refer to SFP MSA.
www.huihongfiber.com [email protected]

















Absolute Maximum Ratings
Table 1 - Absolute Maximum Ratings
Parameter Symbol Min Max Unit
Supply Voltage Vcc -0.5 4.5 V
Storage Temperature Ts -40 +85 C
Operating Humidity - 5 85 %

Recommended Operating Conditions
Table 2 - Recommended Operating Conditions
Parameter Symbol Min Typical Max Unit
Operating Case Temperature
Standard
Tc
0 +70 C
Industrial -40 +85 C
Power Supply Voltage Vcc 3.13 3.3 3.47 V
Power Supply Current Icc 300 mA
Data Rate 2.488 Gbps

Optical and Electrical Characteristics
DS-SFP-FC-2G-LW: (FP and PIN, 1310nm, 2km Reach)
Table 3 - Optical and Electrical Characteristics
Parameter Symbol Min Typical Max Unit Notes
Transmitter
Centre Wavelength c 1260 1310 1360 nm
Spectral Width (RMS) 4 nm
Vcc

Temp
TD+/-
TxFault
TxDis


LOS

RD+/-


SCL
SDA

LD Driver

LD

PIN+TIA Post Amp

MCU
EEPROM ADC/DAC
www.huihongfiber.com [email protected]
Average Output Power Pout -10 -3 dBm 1
Extinction Ratio ER 9 dB
Optical Rise/Fall Time (20%~80%) tr/tf 0.16 ns
Data Input Swing Differential VIN 400 1800 mV 2
Input Differential Impedance ZIN 90 100 110
TX Disable
Disable 2.0 Vcc V
Enable 0 0.8 V
TX Fault
Fault 2.0 Vcc V
Normal 0 0.8 V
Receiver
Centre Wavelength c 1260 1580 nm
Receiver Sensitivity -18 dBm 3
Receiver Overload -3 dBm 3
LOS De-Assert LOSD -20 dBm
LOS Assert LOSA -30 dBm
LOS Hysteresis 1 4 dB
Data Output Swing Differential Vout 370 1800 mV 4
LOS
High 2.0 Vcc V
Low 0.8 V
Notes:
1. The optical power is launched into SMF.
2. PECL input, internally AC-coupled and terminated.
3. Measured with a PRBS 2
23
-1 test pattern @2488Mbps, BER 110
-12
.
4. Internally AC-coupled.

Timing and Electrical
Table 4 - Timing and Electrical
Parameter Symbol Min Typical Max Unit
Tx Disable Negate Time t_on 1 ms
Tx Disable Assert Time t_off 10 s
Time To Initialize, including Reset of Tx Fault t_init 300 ms
Tx Fault Assert Time t_fault 100 s
Tx Disable To Reset t_reset 10 s
LOS Assert Time t_loss_on 100 s
LOS De-assert Time t_loss_off 100 s
Serial ID Clock Rate f_serial_clock 400 KHz
www.huihongfiber.com [email protected]
MOD_DEF (0:2)-High VH 2 Vcc V
MOD_DEF (0:2)-Low VL 0.8 V

Diagnostics
Table 5 Diagnostics Specification
Parameter Range Unit Accuracy Calibration
Temperature
0 to +70
C 3C Internal / External
-40 to +85
Voltage 3.0 to 3.6 V 3% Internal / External
Bias Current 0 to 100 mA 10% Internal / External
TX Power -10 to -3 dBm 3dB Internal / External
RX Power -23 to -3 dBm 3dB Internal / External

Digital Diagnostic Memory Map
The transceivers provide serial ID memory contents and diagnostic information about the present
operating conditions by the 2-wire serial interface (SCL, SDA).

The diagnostic information with internal calibration or external calibration all are implemented,
including received power monitoring, transmitted power monitoring, bias current monitoring, supply
voltage monitoring and temperature monitoring.

The digital diagnostic memory map specific data field defines as following.


















www.huihongfiber.com [email protected]
Pin Definitions
Pin Diagram







Pin Descriptions
Pin Signal Name Description Plug Seq. Notes
1 VEET Transmitter Ground 1
2 TX FAULT Transmitter Fault Indication 3 Note 1
3 TX DISABLE Transmitter Disable 3 Note 2
4 MOD_DEF(2) SDA Serial Data Signal 3 Note 3
5 MOD_DEF(1) SCL Serial Clock Signal 3 Note 3
6 MOD_DEF(0) TTL Low 3 Note 3
www.huihongfiber.com [email protected]
7 Rate Select Not Connected 3
8 LOS Loss of Signal 3 Note 4
9 VEER Receiver ground 1
10 VEER Receiver ground 1
11 VEER Receiver ground 1
12 RD- Inv. Received Data Out 3 Note 5
13 RD+ Received Data Out 3 Note 5
14 VEER Receiver ground 1
15 VCCR Receiver Power Supply 2
16 VCCT Transmitter Power Supply 2
17 VEET Transmitter Ground 1
18 TD+ Transmit Data In 3 Note 6
19 TD- Inv. Transmit Data In 3 Note 6
20 VEET Transmitter Ground 1
Notes:
Plug Seq.: Pin engagement sequence during hot plugging.
1) TX Fault is an open collector output, which should be pulled up with a 4.7k~10k resistor on the host board to a voltage
between 2.0V and Vcc+0.3V. Logic 0 indicates normal operation; Logic 1 indicates a laser fault of some kind. In the
low state, the output will be pulled to less than 0.8V.
2) TX Disable is an input that is used to shut down the transmitter optical output. It is pulled up within the module with a
4.7k~10k resistor. Its states are:
Low (0 to 0.8V): Transmitter on
(>0.8V, < 2.0V): Undefined
High (2.0 to 3.465V): Transmitter Disabled
Open: Transmitter Disabled
3) Mod-Def 0,1,2. These are the module definition pins. They should be pulled up with a 4.7k~10k resistor on the host
board. The pull-up voltage shall be VccT or VccR.
Mod-Def 0 is grounded by the module to indicate that the module is present
Mod-Def 1 is the clock line of two wire serial interface for serial ID
Mod-Def 2 is the data line of two wire serial interface for serial ID
4) LOS is an open collector output, which should be pulled up with a 4.7k~10k resistor. Pull up voltage between 2.0V
and Vcc+0.3V. Logic 1 indicates loss of signal; Logic 0 indicates normal operation. In the low state, the output will be
pulled to less than 0.8V.
5) RD-/+: These are the differential receiver outputs. They are internally AC-coupled 100 differential lines which should be
terminated with 100 (differential) at the user SERDES.
6) TD-/+: These are the differential transmitter inputs. They are internally AC-coupled, differential lines with 100
differential termination inside the module.






www.huihongfiber.com [email protected]
Recommended Interface Circuit



























Mechanical Dimensions

















www.huihongfiber.com [email protected]
Ordering information
Part Number Product Description
HDS-SFP-FC-2G-LW 1310nm, 2.488Gbps, 2km, 0C ~ +70C

You might also like