0% found this document useful (0 votes)
167 views1 page

Hazardous Area Classification

Ignitable concentrations of flammable gases, vapors, or liquids can exist all of the time or some of the time under normal operation conditions. Class 1, div. 2 - Where concentrations of not likely to exist under normal operating conditions. Group: a (acetlyene), B (hydrogen), C (ethylene), D (propane) group: e (metals - div. 1 only), F (coal), G (grain

Uploaded by

yuthonline
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
167 views1 page

Hazardous Area Classification

Ignitable concentrations of flammable gases, vapors, or liquids can exist all of the time or some of the time under normal operation conditions. Class 1, div. 2 - Where concentrations of not likely to exist under normal operating conditions. Group: a (acetlyene), B (hydrogen), C (ethylene), D (propane) group: e (metals - div. 1 only), F (coal), G (grain

Uploaded by

yuthonline
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Hazardous Location Terms Page 1 of 1

Hazardous Locations Classifications Descriptions


Class 1, Div. 1 - Where ignitable concentrations of flammable gases, vapors or liquids can exist all of the time or some of the time under normal operation
conditions.
Class 1, Div. 2 - Where ignitable concentrations of flammable gases, vapors, or liquids are not likely to exist under normal operating conditions.
Class 2, Div. 1 - Where ignitable concentrations of combustible dusts can exist all of the time or some of the time under normal operation conditions.
Class 2, Div. 2 - Where ignitable concentrations of combustible dust are not likely to exist under normal operating conditions.
Class 3, Div. 1 - Where easily ignitable fibers or materials producing combustible flyings are handled, manufactured or used.
Class 3, Div. 2 - Where easily ignitable fibers are stored and handled.
Groups: A (acetlyene), B (hydrogen), C (ethylene), D (propane)
Groups: E (metals - div. 1 only), F (coal), G (grain).
Product Groups
Emergency Units
Z Class 1, Division 2 A, B, C, D
ZX Class 1, Division 1 C, D
ZX Class 1, Division 2 C, D
ZX Class 2, Division 2 F, G
ELA ZX Class 1, Division 1 C, D
ELA ZX Class 1, Division 2 C, D, F, G
ELA ZX Class 2, Division 1 E, F, G
ELA ZCD Class 2, Division 1 E, F, G
Exit Units
LZ Class 1, Division 2 A, B, C, D
LZ Class 2, Division 2 F, G
LHZ Class 1, Division 2 A, B, C, D
LHZ Class 2, Division 2 F, G

Copyright ฉ 2003 Acuity Lighting Group, Inc. | Comments | Updated 03/24/03

http://www.lithonia.com/industrialcd/TechnicalData/Hazardous%20Location%20Terms.... 7/8/2551

You might also like