Tubular Hot Finished Structural Hollow Sections
Tubular Hot Finished Structural Hollow Sections
Tubular Hot Finished Structural Hollow Sections
Applicable standards
This catalogue is based on EN 10210-1/2 standards that are listed in the following table. In all cases, latest editions of these standards shall be used.
EN 10210-1 Hot finished structural hollow sections of non-alloy and fine grain steels Part. 1: Technical delivery conditions
EN 10210-2
Hot finished structural hollow sections of non-alloy and fine grain steels Part. 2: Tolerances, dimensions and sectional properties
Performance characteristics for steel construction ECC directive (CPD) 89/106/EEC (CE Mark)
Tenaris meets all performance characteristics for steel construction stated by ECC directive (CPD) 89/106/EEC as amended by 93/68/EEC. This directive has the purpose to ensure that the constructions and all the products used are made in order not to compromise the safety of persons, animals and property. Tenaris has obtained the EC Factory Production Control Certificate n0038. The tubes will have the CE mark reported on invoicing documents and on material Certificates.
COMPARISON OF EN 10210 (EU) VS. ASTM A500 , A618/A 618M (USA) & CSA G40.21 (CANADA)
Standard Grade Analysis % (max) EN 10210 S355J0H/J2H/K2H C 0,22 Mn 1,60 Yeld Strength Min (MPA) Tensile Strength Min (MPA) Elongation Min % in 2" Impact test Min 355 510 22 J0H at 0C = 27J J2H at -20C = 27J K2H at -20C = 40J ASTM A500 C C 0,23 Mn 1,35 317 427 21 N.A N.A N.A ASTM A618/A 618M II C 0,22 Mn 0,85 -1,35 345 485 22 N.A N.A N.A CSA G40.21 50W C 0,23 Mn 1,35 345 450 22 N.A N.A N.A
EN 10210 (EUROPE) ASTM A500 (USA) ASTM A618/A618 M (USA) CSA G40.21 (CANADA)
Hot finished structural hollow sections of non -alloy and fine grain steels
Cold -Formed Welded and Seamless Carbon Steel Structural Tubing in Rounds and Shapes
Hot -Formed Welded and Seamless High-Strength Low -Alloy Structural Tubing
Order definition
Details (Essential datas): Manufacturing Norms: EN 10210 - Steel grade - Dimensions: External diameter, wall thickness & length in mm - Quantity and relative tolerances Example: EN 10210 S460NH 139,7 x 14,2 x 12000
Steel grades
CHEMICAL ANALYSIS %
GRADE 40 S235JRH S275J0H S275J2H S355J0H S355J2H S355K2H 0,17 0,20 0,20 0,22 0,22 0,22 C Norm. W.T. mm > 40 65 0,20 0,22 0,22 0,22 0,22 0,22 0,55 0,55 0,55 1,40 1,50 1,50 1,60 1,60 1,60 0,040 0,035 0,030 0,035 0,030 0,030 0,040 0,035 0,030 0,035 0,030 0,030 0,009 0,009 0,009 Si Mn P S N
CHEMICAL ANALYSIS %
STEEL GRADE S275NH S275NLH S355NH S355NLH S420NH S420NLH S460NH S460NLH 0,22 0,60 1,00 1,70 0,030 0,025 0,20 0,18 0,22 0,60 1,00 1,70 0,030 0,035 0,025 0,030 0,050 0,20 0,020 0,03 0,30 0,80 0,10 0,70 0,025 0,50 0,90 1,65 0,030 0,035 0,025 0,030 0,050 0,20 0,020 0,03 0,30 0,80 0,10 0,70 0,025 C Si 0,40 Mn 0,50 1,40 0,030 0,035 0,025 0,030 0,050 0,12 0,020 0,03 0,30 0,50 0,10 0,35 0,020 P 0,035 S 0,030 Nb 0,050 V 0,08 Al tot. 0,020 Ti 0,03 Cr 0,30 Ni 0,30 Mo 0,10 Cu 0,35 N 0,015 0,20
MECHANICAL PROPERTIES
STEEL GRADE Min. Yield Strength (ReH) N/mm2 Nominal W.T. mm 0 16 S235JRH S275J0H S275J2H S355J0H S355J2H S355K2 355 345 335 510 680 490 630 22 21 20 19 235 275 >16 40 225 265 > 40 65 215 255 Tensile Strength (Rm) N/mm2 Nominal W.T. mm 3 360 510 430 580 > 3 65 340 470 410 560 Elongation % Minimum Nominal W.T. mm Long. Transv. 40 > 40 65 40 > 40 65 26 22 25 21 24 20 23 19 Impact Strengh Minimum TC 20 0 - 20 0 - 20 - 20 J 27 27 27 27 27 40
STEEL GRADE
Min. Yield Strength (ReH) N/mm2 at specified thickness mm 16 >1640 265 345 400 440 >4065 255 335 390 430
Tensile Strength (Rm) N/mm2 at specified thickness mm Longitudinal 65 370 510 470 630 520 680 540 720
24 22 19 17
22 20 17 15
27 27 27 27
N to indicate normalized condition L for the qualities with specified impact properties at -50 c H to indicate hollow sections
Weldability
Weldability is a key factor for the tubes in structural and engineering applications. Tenaris guarantees the good weldability of its products thanks to its controlled chemical composition with low carbon equivalent.
Carbon Equivalent Value (CEV)
The maximum Carbon Equivalent Value (CEV) is determined, based on the cast analysis, by the following formula: Mn Cr+Mo+V Ni+Cu CEV= C + + + 6 5 15 The maximum CEV for each steel grade is stated on the tables. The steel grades indicated in the specification are weldable with traditional welding procedures, given observance of the generally accepted technical rules. It is important to define a welding procedure that takes into account the following conditions: Thickness of the base material Specific heat imput (specially for HAZ) Design requirements Welding method used Weld material characteristics
-10%(a)(b) max 0.2% of total length and max 3 mm over any 1m length -6%/+8% on individual delivered lengths
Mass (Kg/m)
Particular precautions should be taken towards crack suscetibility, which is more likely to happen with high thickness and high resistance. This phenomenon is connected to the following factors: - Chemical analysis (by means of CEV) - The amount of diffusible hydrogen in the weld material - HAZ micro-structure - Tensile stress concentrations at the weld joint.
a) The positive deviation is limited by the tolerance on mass b) Tenaris can guarantee a WT tolerance in one section of -10%/+15%, average wall thickness shall be such as to comply with minimum and maximum weight per meter
Length
The standard length supplied are from 5 to 12 m inclusive. The length supplied vary with the dimension; for each dimension the range is max 2 m.
Service Center
The Service center can supply tubes cut in fixed lengths with tolerances of -0 +10 mm.
Option
Tests
The product is subjected always to the following tests: - Cast analysis - Tensile test - Impact test - Electromagnetic test acc.to EN 10246-5-Lev.F3 (not required by EN 10210) - Visual inspection
Option
Documentation
For each shipment a Material Test Certificate (MTC) type 3.1 according to EN10204-1 and Packing List (PL) shall be issued containing at least the following information: Customer Name and Customer reference Manufacturer works order Specification and Steel grade Chemical Analysis Mechanical test result Conformance with NDT. Quantities, dimensions and lengths shipped The certificate shall report upon request the declaration: We hereby declare that the above product has been designed, manufactured and tested in accordance to requirement of CPD Directive 93/68/EEC and CE mark n 038
Option
Surface protection
Tubes shall have external and internal bare surfaces
Marking
All pipes shall be stenciled with: TENARIS XX (mill code), heat number, dimensions, specification, grade, CE mark (option). Die Stamping All pipes shall be stamped with: Manufacturers trademark, Steel grade, S (Production Process), Plant Inspector Code.
Options
Quality Assurance
Tenaris mills, in which these products are manufactured, are qualified according to the International Standard ISO9001:2000.
- Other specific marking requirements may be performed upon agreement. - Color coding at one end to be agreed
Packaging
Depending on diameters the packaging will be in loose condition or in bundles.
DIMENSIONS
WALL THICKNESS
mm
OUTSIDE DIAMETER 21,3 26,9 33,7 42,4 48,3 60,3 76,1 88,9 101,6 114,3 139,7 168,3 177,8 193,7 203 219,1 244,5 273 323,9 355,6 406,4 457 508 610 660 711
10
12
16
20
22
26
28
30
33
36
40
45
50
58
60
64
0.840 1.060 1.330 1.670 1.900 2.375 3.000 3.500 4.000 4.500 5.500 6.625 7.000 7.625 8.000 8.625 9.625 10.750 12.750 14.000 16.000
20.000 24.000 26.000 28.000 0.094 0.106 0.126 0.142 0.157 0.177 0.205 0.256 0.315 0.354 0.394 0.472 0.630 0.787 0.866 1.024 1.102 1.181 1.299 1.417 1.575 1.772 1.969 2.283 2.362 2.520
inch.
WALL THICKNESS
Other dimensions not shown can be produced on request. According to EN 10210-2 To be agreed
For steel grade S420 MLH, 460NLH any request for quote has to be verified with a technical query (Product Engineering Department)
OUTSIDE DIAMETER
18.000
Contact Us
EUROPE
Alessandro Giacobbe [email protected] (39) 035 560 2332 tel (39) 035 560 3990 fax
ARGENTINA Buenos Aires Marcelo de Virgiliis [email protected] (54) 11 4018 3213 tel (54) 11 4018 8373 fax CANADA Toronto George Nogalo [email protected] (1) 416 216 4617 tel (1) 416 214 2043 fax CHINA Beijing Alexis Guadarrama [email protected] (86) 10 8459 7803 tel (86) 10 6437 6746 fax GERMANY Mnchen Marc Rennings [email protected] (49) 89 232375 222 tel (49) 89 232375 200 fax
ITALY Dalmine Alessandro Giacobbe [email protected] (39) 35 560 2332 tel (39) 35 560 3990 fax KOREA Seoul Leandro Ramos [email protected] (82) 2 798 3385 tel (82) 2 798 3392 fax MEXICO Veracruz Victor Palencia [email protected] (52) 55 5282 9943 tel (52) 55 5282 9966 fax ROMANIA Zalau Andras Balogh [email protected] (40) 260 603 223 tel (40) 260 610 743 fax
SCANDINAVIA Mnchen Marc Rennings [email protected] (49) 89 232375 222 tel (49) 89 232375 200 fax UK Coseley Kevin Whitehouse [email protected] (44) 1902 665288 (44) 1902 665263 USA Houston Juan Muhala [email protected] (1) 713 767 4416 tel (1) 713 582 1650 fax
Tenaris and its member companies have produced this catalogue for general information only. Tenaris does not assume any responsibility or liability for any loss, damage, injury resulting from the use of information and data herein. Warranties, indemnities and any other obligations will result only from the respective contracts of license or sale, as the case may be. Please contact a Tenaris representative for more complete information, and for information on other Tenaris products not shown here which are also available upon request. Tenaris 2009. All rights reserved.