0% found this document useful (0 votes)
20 views

International Limited: Report For Visual Examination and Magnetic Particle Inspection

JC International Limited conducted a visual examination and magnetic particle inspection of the draw work anchor point DW 1 on Rig Floor of the Adriatic X for Transocean Support Services. The welded area of the draw work anchor point was examined and found to be fit for use according to ASTM E 1444 standards. The report was prepared by Jaaphet Omefe, a qualified inspector, and signed on 20/10/2013.

Uploaded by

Michael Okwuwa
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
20 views

International Limited: Report For Visual Examination and Magnetic Particle Inspection

JC International Limited conducted a visual examination and magnetic particle inspection of the draw work anchor point DW 1 on Rig Floor of the Adriatic X for Transocean Support Services. The welded area of the draw work anchor point was examined and found to be fit for use according to ASTM E 1444 standards. The report was prepared by Jaaphet Omefe, a qualified inspector, and signed on 20/10/2013.

Uploaded by

Michael Okwuwa
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

JC International Limited

RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

REPORT FOR VISUAL EXAMINATION AND MAGNETIC PARTICLE INSPECTION

Report No.: 130682

Equipment Description: Equipment ID: Location: Specification: Part Examined: Comment:

Draw Work Anchor Point DW 1 RIG FLOOR (ADRIATIC X) ASTM E 1444 Welded Area Fit for use

Name of Client:

TRANSOCEAN SUPPORT SERVICES

Inspectors Name/Qualification JAPHET OMEFE


FMLP, LEEA, SNT LEVEL II MT, PT, UT Lifting Equipment Insp.

Signature/Date

20/10/2013